Cisco UCS C260 M2

High-Performance 

 

Rack-Mount Server

Содержание UCS C260 M2

Страница 1: ...CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR SAN JOSE CA 95134 REV B 2 NOVEMBER 15 2013 WWW CISCO COM Spec Sheet Cisco UCS C260 M2 High Performance Rack Mount Server ...

Страница 2: ...ORD s 26 STEP 11 ORDER TOOL LESS SLIDE RAIL KIT 29 STEP 12 ORDER OPTIONAL CABLE MANAGEMENT ARM 29 STEP 13 ORDER OPTIONAL USB BOOT DRIVE 30 STEP 14 ORDER OPTIONAL NETWORK CARD ACCESSORIES 31 STEP 15 ORDER A TRUSTED PLATFORM MODULE 34 STEP 16 CHOOSE OPERATING SYSTEM AND VALUE ADDED SOFTWARE 35 STEP 17 CHOOSE OPERATING SYSTEM MEDIA KIT 38 STEP 18 CHOOSE SERVICE and SUPPORT LEVEL 39 OPTIONAL STEP ORDE...

Страница 3: ...U rack server designed for compute I O storage and memory intensive standalone applications The UCS C260 M2 server Figure 1 extends the capabilities of the Cisco Unified Computing System using Intel s latest Xeon E7 2800 Series multi core processors to deliver increased performance and efficiency Figure 1 Cisco UCS C260 M2 High Density Rack Server Front View Rear View ...

Страница 4: ...e KVM CABLE on page 51 1 Modular drive bay 1 8 System status LED 2 Operator panel 9 Fan status LED 3 Modular drive bay 2 10 Temperature status LED 4 Hard drive activity LED 11 Power supply status LED 5 Hard drive fault LED 12 Network link activity LED 6 Power button LED 13 Asset tag serial number 7 Identification button LED 14 KVM connector used with KVM cable that provides two USB one VGA and one...

Страница 5: ...ts supported with optional card in designated PCIe slot 4 4 Five PCIe slots on motherboard 4 low profile half length x8 slots and 1 low profile half length x4 slot PCIe slot numbering is 2 3 4 5 6 left to right 12 RAID controller cards up to two supported in designated PCIe slots 3 and 5 5 Horizontal PCIe slot PCIe slot 7 standard profile half length x16 13 1 Gigabit Base T LOM ports two RJ 45 por...

Страница 6: ... expansion ASIC each of the 16 risers can hold 4 DIMMs This provides a possible total of up to 64 DIMMs and 1024 GB of industry standard DDR3 memory Cisco FlexFlash drives The server includes one internal Cisco FlexFlash drive which is included on the I O riser card This drive is pre loaded with four virtual drives implemented as flash memory The four virtual drives contain respectively the Cisco ...

Страница 7: ...ncludes a Matrox G200 core The first 8 MB of memory are allocated to the video core Interfaces Rear panel Two 10 100 dedicated management Ethernet ports Two 1 Gigabit Base T Ethernet ports 10 100 1000 Mbps capable Two 10 Gigabit SFP Ethernet ports on optional modular card One RS232 serial connector on I O riser card One 15 pin VGA connector on I O riser card Four USB 2 0 connectors Front panel One...

Страница 8: ...Ie OPTION CARD S page 20 STEP 8 CHOOSE SECURE DIGITAL SD CARD page 24 STEP 9 CHOOSE POWER SUPPLIES page 25 STEP 10 SELECT AC POWER CORD s page 26 STEP 11 ORDER TOOL LESS SLIDE RAIL KIT page 29 STEP 12 ORDER OPTIONAL CABLE MANAGEMENT ARM page 29 STEP 13 ORDER OPTIONAL USB BOOT DRIVE page 30 STEP 14 ORDER OPTIONAL NETWORK CARD ACCESSORIES page 31 STEP 15 ORDER A TRUSTED PLATFORM MODULE page 34 STEP ...

Страница 9: ...260 BASE 2646 base server Does not include CPUs memory riser boards hard disk drives HDDs solid state Drives SSDs or plug in PCIe cards Table 2 PID of the Base C260 M2 Rack Server Product ID PID Description C260 BASE 2646 UCS C260 M2 Rack Server w o CPU MRB PSU NOTE Use the steps on the following pages to configure the server with the components that you want to include ...

Страница 10: ...uration Choose two identical CPUs from Table 3 Caveats You must select two identical processors Table 3 Available CPUs Intel Xeon Westmere E7 28xx 8867L Family Product ID PID Intel Number Clock Freq GHz Power W Cache Size MB Cores QPI Highest DDR3 DIMM Clock Support MHz UCS CPU E72870 E7 2870 2 40 130 30 10 6 40 1333 UCS CPU E72860 E7 2860 2 26 130 24 10 6 40 1333 UCS CPU E78867L E7 8867L 2 13 105...

Страница 11: ...h CPU controls eight Millbrook 2 DDR3 channels There is one memory riser board for each DDR3 channel Memory is organized as paired DIMM memory channels Choose Riser Boards You may choose eight or sixteen riser boards If you choose eight four will be installed per CPU If you choose sixteen eight will be installed per CPU Approved Configurations 1 Eight Two Socket Risers 16 DIMMs capacity total 2 Si...

Страница 12: ...in an equal number of matched DIMMs Each CPU can boot and run from a single matched pair of risers Choose DIMMs DIMMs are orderable as kits with two DIMMs per kit Choose the desired number of DIMMs The available memory DIMMs are listed in Table 5 Approved Configurations 1 Two Socket Risers Each two socket riser can accommodate two DIMMs If you ordered eight two socket risers you can order a minimu...

Страница 13: ...ixteen four socket risers you can order a minimum of two DIMM kits four DIMMs and a maximum of thirty two DIMM kits 64 DIMMs Caveats Matched pairs of risers on paired DDR3 channels must have identical DIMM configurations For example the DIMM configurations must be identical on risers in the A0 A1 paired DIMM channels however the A0 A1 DIMM configuration does not have to be identical with the B0 B1...

Страница 14: ...OSE MODULAR DRIVE BAYS page 16 you may select up to sixteen drives You can mix SAS and SATA drives Table 6 Available Hot Pluggable Sled Mounted HDDs and SSDs Product ID PID PID Description Drive Type Capacity HDDs A03 D146GC2 146 GB SAS 15K RPM SFF HDD SAS 146 GB A03 D300GA2 300 GB 6 Gb SAS 10K RPM SFF HDD SAS 300 GB A03 D500GC3 500 GB 6 Gb SATA 7 2K RPM SFF SATA 500 GB A03 D600GA2 600 GB 6 Gb SAS...

Страница 15: ...G the SERVER 15 Caveats You can mix hard drives and SSDs in the same server However You cannot configure a logical volume virtual drive that contains a mix of hard drives and SSDs That is when you create a logical volume it must contain all hard drives or all SSDs ...

Страница 16: ...drives 5 through 8 on the backplane Expander optional One internal cable from the transition card to a plug in RAID controller card is required to control eight drives This one connector allows control of drives 1 through 8 on the backplane Choose Drive Bays Choose one or two of the drive bays listed in Table 7 Approved Configurations 1 One Standard Drive Bay with Nonexpander Transition Card This ...

Страница 17: ...ID controller is required to control all sixteen drives One cable must be connected to the RAID controller from each transition card Caveats You cannot mix drive bay types You must order either one or two identical drive bay types listed in Table 7 on page 16 NOTE With this configuration two RAID controllers can also be installed with one cable from each transition card to each RAID controller ...

Страница 18: ...ntroller takes up one PCIe slot slots 3 and 5 are used for RAID controllers Supports from one to sixteen internal SAS or SATA drives depending on the type of transition board installed One drive bay with nonexpander transition board up to eight drives supported with one RAID controller having two cables connected to the transition card Two drive bays with nonexpander transition boards up to sixtee...

Страница 19: ...e an optional RAID configuration RAID 0 1 5 6 or 10 which is pre configured at the factory If you do not choose a RAID configuration the disks will be configured as a JBOD RAID Configuration R2XX RAID0 Factory pre configured RAID striping option Enable RAID 0 Setting Requires a minimum of 1 hard drive R2XX RAID1 Factory pre configured RAID mirroring option Enable RAID 1 Setting Requires exactly 2 ...

Страница 20: ...CIE ESFP Emulex OCe11102 FX Dual Port 10Gb SFP CNA Half N2XX AEPCI01 Emulex 10Gb 2 Port CNA Half UCSC PCIE B3SFP Broadcom 57810 10Gb A FEX SFP Half Network Interface Cards NICs UCSX MLOM 001 10GbE PCIe LOM dual port SFP Full N2XX ABPCI03 M3 Broadcom 5709 Quad Port 1Gb w TOE iSCSI for M3 Servers Half N2XX AIPCI01 Intel Dual Port 10 GbE Ethernet X520 Server Adapter Half N2XX AIPCI02 Intel Quad port ...

Страница 21: ...785 GB MLC Fusion ioDrive2 for C Series Servers Half UCSC F FIO 365M Cisco UCS 365GB MLC Fusion ioDrive2 for C Series Servers Half Table 10 Recommended PCIe Slot Population PCIe Card Type Primary Slot Secondary Slot Alternate Slots RAID Controller 3 5 Low profile NIC 6 3 1 2 5 or 7 Cisco UCS 1225 Virtual Interface Card 7 1 10GbE PCIe LOM dual port SFP 41 Notes 1 Slot 4 is reserved for the 10 GbE P...

Страница 22: ...SM only slot 7 is supported for the VIC card Additional considerations for the Cisco 1225 VIC card Table 11 PCIe Expansion Slot Numbering Slot Number Slot Characteristics 7 on riser card PCI Express Gen 2x16 x16 connector half length standard profile 6 PCI Express Gen 2x8 x8connector half length low profile 5 PCI Express Gen 2x8 x8connector half length low profile 4 PCI Express Gen 2x8 x8connector...

Страница 23: ...mware version 1 4 6 or later installed There is a heartbeat LED on the top of the card that indicates when firmware is active To use this card for UCS integration Cisco UCS Manager mode with Cisco UCS Manager 2 1 0 or later the minimum card firmware and uboot image level is 2 1 0 306 To help ensure that your operating system is compatible with the cards you have selected please check the Hardware ...

Страница 24: ...E SECURE DIGITAL SD CARD One 16 GB SD flash memory card is required to be inserted into a dedicated I O riser card plugged into the motherboard Select one SD card from Table 12 Table 12 Available SD Card Product ID PID PID Description Card Height UCSC SD 16G C260 16GB SD card for C260 M2 Half ...

Страница 25: ...erver CONFIGURING the SERVER 25 STEP 9 CHOOSE POWER SUPPLIES Two 1200 W power supplies are required Select two power supplies from Table 13 Table 13 Available Power Supplies Product ID PID PID Description UCSC PSU2 1200 1200W 2u Power Supply For UCS ...

Страница 26: ...e 14 Available Power Cords Product ID PID PID Description Images R2XX DMYMPWRCORD No power cord dummy PID to allow for a no power cord option Not applicable CAB N5K6A NA Power Cord 200 240V 6A North America CAB AC L620 C13 AC Power Cord NEMA L6 20 C13 2M 6 5ft CAB C13 CBN CABASY WIRE JUMPER CORD 27 L C13 C14 10A 250V CAB C13 C14 2M CABASY WIRE JUMPER CORD PWR 2 Meter C13 C14 10A 250V CAB C13 C14 A...

Страница 27: ... continued Product ID PID PID Description Images 186571 2500 mm Cordset rating 10 A 250 500 V MAX Length 8 2 ft Plug EL 219 IRAM 2073 Connector EL 701 IEC60320 C13 Plug Cordset rating 10 A 250 V 500 V MAX Length 2500mm 186580 Connector EL 701C EN 60320 C15 EL 210 BS 1363A 13 AMP fuse Cordset rating 10A 250V 2500 mm Plug EL 218 CCEE GB2009 186573 Connector EL 701 IEC60320 C13 Connector VSCC15 Cords...

Страница 28: ...AB 250V 10A BR Power Cord 250V 10A Brazil CAB JPN 3PIN Power Cord 3PIN Japan Image not available Table 14 Available Power Cords continued Product ID PID PID Description Images Plug I 3G CEI 23 16 Connector C15M EN60320 C15 Cordset rating 10 A 250 V Length 8 ft 2 in 2 5 m 186575 Plug MP232 R Cordset rating 10 A 250 V Length 8 ft 2 in 2 5 m 186578 Connector IEC 60320 C15 Plug Cordset rating 10 A 250...

Страница 29: ...lide rail kit listed in Table 15 STEP 12 ORDER OPTIONAL CABLE MANAGEMENT ARM The cable management arm attaches to the left slide rail at the rear of the server and is used for cable management You can order one of the cable management arms listed in Table 16 Table 15 Cable Management Arm Product ID PID PID Description UCSC RAIL 2U 2U Rail Kit for UCS C Series servers Table 16 Cable Management Arm ...

Страница 30: ...may be ordered and used as a boot drive The USB drive plugs into a vertical USB slot on the motherboard You can order the USB boot drive listed in Table 17 Approved Configurations Select one USB drive from Table 17 Caveats None Table 17 Available USB Drive Product ID PID PID Description Drive Type Capacity UCS USBFLSH 4GB 4GB USB Drive USB 4 GB ...

Страница 31: ...ed You may choose one or two twinax cables for each network card ordered The cables can be different lengths however you would normally order two cables of equal lengths to connect to the primary and redundant network switching equipment Caveats The twinax cables listed in Table 18 can be ordered only for the following PCIe cards UCS PCIE BSFP Broadcom 57712 N2XX ABPCI02 Broadcom 57711 N2XX AIPCI0...

Страница 32: ... SFP 10G SR optical module listed in Table 19 should be ordered only for the following PCIe cards as they do not come by default with any optical modules UCSC PCIE BSFP Broadcom 57712 N2XX ABPCI02 Broadcom 57711 UCSC PCIE CSC 02 Cisco VIC 1225 Dual Port 10Gb SFP CNA UCSC PCIE ESFP Emulex OCe11102 FX Dual Port 10Gb SFP CNA The DS SFP FC8G SW optical module listed in Table 19 should be ordered only ...

Страница 33: ...Cisco UCS C260 M2 High Performance Rack Mount Server CONFIGURING the SERVER 33 Figure 5 Network Card Connections ...

Страница 34: ...ion keys A TPM can also be used to store platform measurements that help ensure that the platform remains trustworthy Authentication ensuring that the platform can prove that it is what it claims to be and attestation a process helping to prove that a platform is trustworthy and has not been breached are necessary steps to ensure safer computing in all environments The TPM ordering information is ...

Страница 35: ...SUSE Linux Enterprise Server SLES 1A SLES 1yr subscription svcs required 0 media SLES 3A SLES 3yr subscription svcs required 0 media UCS SLES TERMS Acceptance of Terms Standalone SLES License for UCS Servers Red Hat Enterprise Linux RHEL 2S 1G 1A RHEL 2 Socket 1 Guest 1Yr Svcs Required RHEL 2S 1G 3A RHEL 2 Socket 1 Guest 3Yr Svcs Required RHEL 2S 4G 1A RHEL 2 Socket 4 Guest 1Yr Svcs Required RHEL ...

Страница 36: ...essor 4 Year Support Rqd VMW VS5 STD 5A VMware vSphere 5 Standard for 1 Processor 5 Year Support Rqd VMW VS5 ENT 1A VMware vSphere 5 Enterprise for 1 Processor 1 Year Support Rqd VMW VS5 ENT 2A VMware vSphere 5 Enterprise for 1 CPU 2 Yr Support Rqd VMW VS5 ENT 3A VMware vSphere 5 Enterprise for 1 CPU 3 Yr Support Rqd VMW VS5 ENT 4A VMware vSphere 5 Enterprise for 1 Processor 4 Year Support Rqd VMW...

Страница 37: ...GURING the SERVER 37 VMW VC5 STD 5A VMware vCenter 5 Server Standard 5 yr support required UCS VMW TERMS Acceptance of Terms Standalone VMW License for UCS Servers Table 21 OSs and Value Added Software for 2 CPU servers continued PID Description Product ID PID ...

Страница 38: ...scription RHEL 6 RHEL 6 Recovery Media Only Multilingual SLES 11 SLES 11 media only multilingual MSWS 08R2 STHV RM Windows Svr 2008 R2 ST 1 4CPU 5CAL Media MSWS 08RS ENHV RM Windows Svr 2008 R2 EN 1 8CPU 25CAL Media MSWS 08R2 DCHV RM Windows Svr 2008 R2 DC 1 8CPU 25CAL Media MSWS 12 ST2S RM Windows Server 2012 Standard 2 CPU 2 VMs Recovery Media MSWS 12 DC2S RM Windows Server 2012 Datacenter 2 CPU...

Страница 39: ...reatens business continuity the TAM provides crisis management leadership and your IT staff receives expedited access to Cisco s Technical Assistance Center TAC Please note This service has qualification criteria Your company must have 1 2M of UCS equipment 200 blades and a single location to qualify for this service level Choose the desired service listed in Table 23 Unified Computing Support Ser...

Страница 40: ...rials authorization RMA is required You can choose a service listed in Table 25 Table 24 UCS Computing Support Service Product ID PID On Site Description CON UCS1 C260 M2 No UC Support 8X5XNBD CON UCS2 C260 M2 No UC Support 8X5X4 CON UCS3 C260 M2 No UC Support 24x7x4 CON UCS4 C260 M2 No UC Support 24x7x2 CON UCS5 C260 M2 Yes UC Support 8X5XNBD CON UCS6 C260 M2 Yes UC Support 8X5X4 CON UCS7 C260 M2...

Страница 41: ...tial liabilities This service also enables you to comply with regulatory local and federal requirements If your company has a need to control confidential classified sensitive or proprietary data you might want to consider one of the Drive Retention Services listed in Table 26 NOTE Cisco does not offer a certified drive destruction service as part of this service Table 26 Drive Retention Service O...

Страница 42: ... URL http www cisco com en US products ps10312 serv_group_home html UCS Warranty Plus With Drive Retention UC PLUS DR UCWD2 8x5x4 CON UCWD2 C260 M2SFF UCWD3 24x7x4 CON UCWD3 C260 M2SFF UCWD4 24x7x2 CON UCWD4 C260 M2SFF UCWD5 8x5xNBD Onsite CON UCWD5 C260 M2SFF UCWD6 8x5x4 Onsite CON UCWD6 C260 M2SFF UCWD7 24x7x4 Onsite CON UCWD7 C260 M2SFF UCWD8 24x7x2 Onsite CON UCWD8 C260 M2SFF Table 26 Drive Re...

Страница 43: ...e information about the R42610 rack see RACKS on page 48 Table 27 Racks and Rack Options Product ID PID PID Description RACK UCS1 Notes 1 Use these same base PIDs to order spare racks available only as next day replacements Cisco R42610 expansion rack no side panels RACK UCS21 Cisco R42610 standard rack w side panels RACK BLANK 001 Filler panels qty 12 1U plastic toolless RACK CBLMGT 001 Cable mgt...

Страница 44: ...lable from Cisco for the C Series rack servers including theC260 M2 server This PDU is available in a zero rack unit RU style see Table 27 For more information about the PDU see PDUs on page 50 Table 28 PDU Options Product ID PID PID Description RP208 30 1P U 1 Cisco Single Phase PDU 2x C13 4x C19 RP208 30 1P U 2 Cisco Single Phase PDU 20x C13 4x C19 ...

Страница 45: ... High Performance Rack Mount Server SUPPLEMENTAL MATERIAL 45 SUPPLEMENTAL MATERIAL CHASSIS An internal view of the C260 M2 chassis with the top cover removed is shown in Figure 6 Figure 6 C260 M2 With Top Cover Removed ...

Страница 46: ... DIMM risers Do not mix riser types Memory risers must be installed in pairs on paired DDR3 channels Paired channels are CPU1 A0 A1 B0 B1 C0 C1 D0 D1 CPU2 A0 A1 B0 B1 C0 C1 D0 D1 Matched pairs of risers on paired DDR3 channels must have identical DIMM configurations For example the DIMM configurations must be identical on risers in A0 A1 however the A0 A1 configurations do not have to be identical...

Страница 47: ...ute riser pairs evenly across the CPUs Follow the recommended installation order shown in Table 29 and refer to Figure 7 on page 46 Table 29 Recommended Memory Riser Installation Order Installation Order CPU Number Memory Riser Channel Pair 1 CPU1 A0 A1 CPU2 A0 A1 2 CPU1 C0 C1 CPU2 C0 C1 3 CPU1 B0 B1 CPU2 B0 B1 4 CPU1 D0 D1 CPU2 D0 D1 ...

Страница 48: ...ns Parameter Standard Rack Expansion Rack Dimensions H x W x D 78 74 x 24 x 43 38 in 2000 x 610 x 1102 mm 78 74 x 23 58 x 43 38 in 2000 x 599 x 1102 mm Dimensions H x W x D with packaging 89 x 33 x 47 in 2261 x 838 x 1194 mm 89 x 33 x 47 in 2261 x 838 x 1194 mm Distance from front mounting rail to rear mounting rail 29 2 in 741 mm 29 2 in 741 mm Weight 299 83 lb 136 kg 231 49 lb 105 kg Weight with...

Страница 49: ...Cisco UCS C260 M2 High Performance Rack Mount Server SUPPLEMENTAL MATERIAL 49 Figure 8 Cisco R42610 Rack Front view door closed Front view door open Front view door removed ...

Страница 50: ...rack you can replace up to two dozen input power cords with just one The fixed input cord connects to the power source from overhead or under floor distribution Your IT equipment is then powered by PDU outlets in the rack using short easy to manage power cords The C series severs accept the zero rack unit 0RU PDU See Figure 9 Figure 9 Zero Rack Unit PDU PID RP208 30 2P U 2 Cisco RP Series PDU mode...

Страница 51: ...s for a keyboard and mouse With this cable you can create a direct connection to the operating system and the BIOS running on the server The KVM cable ordering information is listed in Table 31 Figure 10 KVM Cable Table 31 KVM Cable Product ID PID PID Description 37 1016 01 KVM Cable 1 Connector to server front panel 3 VGA connector for a monitor 2 DB 9 serial connector 4 Two port USB connector fo...

Страница 52: ...e rail brackets 31 5 in 80 cm Front Clearance 3 in 7 62 cm Side Clearance 1 in 2 54 cm Rear Clearance 6 in 15 24 cm Weight maximum configuration including slide rail brackets and cable management arm 92 lbs 41 7 kg Table 33 UCS C260 M2 Power Specifications Description Specification AC input voltage 100 to 127 VAC nominal Range 90 to 264 VAC AC input frequency 50 to 60 Hz nominal Range 47 to 63 Hz ...

Страница 53: ...m Humidity nonoperating 5 to 93 noncondensing Vibration nonoperating 2 2 Grms 10 minutes per axis on each of the three axes Shock operating Half sine 2 G 11 ms pulse 100 pulses in each direction on each of the three axes Shock nonoperating Trapezoidal 25 G two drops on each of six faces Velocity 175 inches per second on bottom face drop Velocity 90 inches per second on the other five faces Electro...

Страница 54: ...tory Compliance Products should comply with CE Markings per directives 2004 108 EC and 2006 95 EC Safety UL 60950 1 Second Edition CAN CSA C22 2 No 60950 1 Second Edition EN 60950 1 Second Edition IEC 60950 1 Second Edition AS NZS 60950 1 GB4943 2001 EMC Emissions 47CFR Part 15 CFR 47 Class A AS NZS CISPR22 Class A CISPR22 Class A EN55022 Class A ICES003 Class A VCCI Class A EN61000 3 2 EN61000 3 ...