CONFIGURING the SERVER
Approved Configurations
(1) Integrated SATA RAID 0/1 controller
■
Select up to 4 SATA (only) drives listed in
Table 8
. You cannot mix HDD and SDD SATA drive
types.
(2) LSI 1064E 4-port SAS 6.0G RAID Mezzanine card RAID controller
■
Select up to four SAS or SATA drives listed in
Table 8
. You cannot mix HDD and SSD drives.
You cannot mix SAS and SATA drive types.
(3) LSI MegaRAID SAS 9280-4i4e RAID controller
■
Select up to four SAS or SATA internal drives listed in
Table 8
for configurations with the
factory-default extender. You cannot mix HDD and SSD drive types or SAS and SATA drives.
(4) LSI MegaRAID SAS 9261-8i RAID controller
■
Select up to eight internal SAS or SATA drives listed in
Table 8
. You can mix SAS and SATA
drives but you cannot mix HDD and SSD drive types. If you order the optional SAS Expander,
the controller can support up to 16 internal drives.
Caveats
■
If the integrated RAID controller on the server motherboard is used (no PCIe or mezzanine
card controller selected), all the drives must be SATA.
A SAS Extender is not field-upgradable to a SAS Expander, so if you are configuring a system with
eight or more drives or anticipate the system will implement more than eight drives in the
future, make sure you order a SAS Expander. You can replace an extender or expander only with
the same type of card.