background image

Using the MCU

14

Using the MCU

Creating conferences

To create a conference:
1

In the web interface of the MCU, go to 

Conferences

 and click 

Add new 

conference

.

2

Type  a 

Name

 for the conference, for example 

SalesMeeting

.

3

Type an optional numeric identifier, for example 

123

. This will be the 

telephone number that participants can use to join the conference when calling 
in to the MCU via a gatekeeper or SIP registrar.

4

If you are using a gatekeeper, select 

H.323 gatekeeper

; if you are using a SIP 

registrar, select 

SIP registrar

.

5

Ensure the 

Maximum duration

 of the conference is sufficient (the default is one 

hour).

6

All other values can be left at their default settings. Refer to the online help for 
further information about the available settings.

7

Scroll down and click 

Add conference

.

The conference you have created is now active (if you used the default immediate 
start time) and participants can join in one of two ways: either the MCU can call out 
to specified endpoints or endpoints can dial in. Any endpoints that have been added 
to a conference, as pre-configured participants, will be called in to the conference by 
the MCU.

There are two types of conference participant: chairperson and guest. 
IDs and PINs allow participants to connect to conferences as the correct 
participant type. Chairperson participants use the Numeric ID and 
optionally, the PIN; guest participants use the Guest numeric ID and 
optionally, the Guest PIN. For more information, refer to the online help.

Note that if you do not configure the conference to start immediately, it 
will become a scheduled conference and will be inactive until its start 
time.

i

i

Содержание TelePresenceMCU 5300 Series

Страница 1: ...Cisco TelePresence MCU 5300 Series Getting started D14876 01 ...

Страница 2: ...n IP address to the MCU optional 8 Step four Discover the IP address of the MCU 9 Configuring the MCU 10 Step one Log in to the MCU 10 Step two Using an H 323 gatekeeper or SIP registrar optional 10 Step three Add endpoints optional 11 Clustering MCUs 12 Using the MCU 14 Creating conferences 14 Calling participants in to a conference 15 Calling in to a conference 15 Instructing conference particip...

Страница 3: ...ackage contents The following items are included with the MCU Verify that you have these items before installing the device Cisco TelePresence MCU unit Console cable blue Power cable Rack mounting kit If you intend to cluster MCUs a Cisco TelePresence MCU 5300 Series Stacking Cable must be ordered separately Please contact your reseller or go to www cisco com Port and LED location Figure 1 on the ...

Страница 4: ...as developed a fault for example temperature is outside normal limits fan failure battery failure of the internal clock Refer to the web interface for more information about the problem go to Status Health Power Blue The MCU is receiving power Link Green Illuminated when the link between stacked MCUs is active Net B Green Illuminated when there is activity on network Port B Net A Green Illuminated...

Страница 5: ...n Illuminated when the link between stacked MCUs is active Net A Green Orange Left LED illuminated green when the interface has established a link Right LED illuminated orange when there is activity on the interface Net B Green Orange Left LED illuminated green when the interface has established a link Right LED illuminated orange when there is activity on the interface ...

Страница 6: ...et cable from Ethernet Port A to an Ethernet switch IMPORTANT Before installing the MCU you must read the safety information at http www cisco com go telepresence safety Only connect to Ethernet Port B if you need to connect the MCU to a second subnet Do not connect Ethernet Port A and Ethernet Port B to the same subnet Failing to configure both sides of the Ethernet connection in the same way can...

Страница 7: ...ntrol none 4 Press Enter and the following command prompt appears on the terminal MCU Step two Configure Ethernet Port A settings The default setting for the MCU Ethernet ports is auto sensing mode If the switch ports to which you connect the MCU are not also set to auto sensing mode then you need to configure the MCU Ethernet ports to use the same speed and duplex mode Only connect to Ethernet Po...

Страница 8: ...p To assign a static IPv4 address to Port A use the following command static A IP address netmask default gateway address For example to assign an address of 192 168 1 2 where the default gateway is at 192 168 1 1 enter static A 192 168 1 2 255 255 255 0 192 168 1 1 To set DNS manually use this command dns DNS server address secondary DNS server domain To return to using DHCP after setting a stati...

Страница 9: ...uire its address using DHCP the IP address that has been acquired by Ethernet Port A will be shown if you have assigned a static IP address that is the address that will be shown 2 Make a note of the IP address You will use this to access the web interface of the unit Note When your MCU has an IP address you can add an entry for it on your DNS server and use that host name to access the MCU s web ...

Страница 10: ...s to call in to a conference To configure the MCU to use an H 323 gatekeeper 1 In the web interface of the MCU go to Settings H 323 2 Enable H 323 gatekeeper usage and configure the settings you require using the online help for further assistance 3 Click Apply changes To configure the MCU to use a SIP registrar 1 In the web interface go to Settings SIP 2 Enable SIP registrar usage and configure t...

Страница 11: ... from the Pre configured participants list This is easier than entering each endpoint s details every time Participants that are pre configured for a conference will automatically be called by the MCU to join that conference To define pre configured endpoints 1 In the web interface of the MCU go to Endpoints To add a H 323 endpoint click Add H 323 To add a SIP endpoint click Add SIP 2 Configure th...

Страница 12: ... Plug each end of the stacking cable into the Link sockets on the rear of the MCUs If your cable has a protective tape or cap on the end remove them so the metal conductors are visible within the plug Check the orientation of the plug when inserting it into the Link socket To remove the cable pull the release mechanism to detach the plug Do not pull directly on the plug Step two Configure the mast...

Страница 13: ... to confirm that the MCU has been correctly configured as the slave When you have configured the units as master and slave do not use the web interface of the slave unit for normal operations All statistics and configuration information for the cluster can be accessed via the web interface of the master unit The slave web interface is only used for upgrading code and for network configuration ...

Страница 14: ...tion about the available settings 7 Scroll down and click Add conference The conference you have created is now active if you used the default immediate start time and participants can join in one of two ways either the MCU can call out to specified endpoints or endpoints can dial in Any endpoints that have been added to a conference as pre configured participants will be called in to the conferen...

Страница 15: ...strar enter the number alphanumeric URI registered with the SIP registrar for the required endpoint 4 Leave the other fields as their default values and click Call endpoint The MCU automatically connects to the endpoint 5 If the endpoint is not configured to automatically answer calls accept the call on the endpoint Calling in to a conference Participants can call in to conferences in either one o...

Страница 16: ... conferences You can also tell them how to navigate the Conference Control Menus via keypad tones and use Far End Camera Controls FECC to navigate menus There is a document Getting Started Accessing Conferences available in the documentation area of the Cisco web site which you can print out and give to conference participants ...

Страница 17: ...e for the MCU 4 If a more recent release is available download it and save it locally To upgrade the MCU 1 Unzip the software release file that you downloaded 2 In the MCU web interface go to Settings Upgrade 3 In the Main software image section click Browse and locate the unzipped file 4 Click Upload software image The browser begins uploading the file to the MCU and a new browser window opens to...

Страница 18: ...w the individual features and settings work If you cannot find the answer you need check the web site at http www cisco com cisco web support index html where you will be able to Make sure that you are running the most up to date software Find further relevant documentation for example product user guides printable versions of the online help reference guides and articles that cover many frequentl...

Страница 19: ... static wrist strap to an appropriate earth point Table 3 MCU 5300 Series ratings Rating Value Nominal voltage 115V to 230V 50 60 Hz Current rating 6A Maximum Supply voltage range 100 to 240V 50 60 Hz Caution over current devices must meet applicable national and local electrical safety codes and be approved for the intended application Table 4 Operating environment Environment Temperature Humidit...

Страница 20: ...AIM ALL WARRANTIES EXPRESSED OR IMPLIED INCLUDING WITHOUT LIMITATION THOSE OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT OR ARISING FROM A COURSE OF DEALING USAGE OR TRADE PRACTICE IN NO EVENT SHALL CISCO OR ITS SUPPLIERS BE LIABLE FOR ANY INDIRECT SPECIAL CONSEQUENTIAL OR INCIDENTAL DAMAGES INCLUDING WITHOUT LIMITATION LOST PROFITS OR LOSS OR DAMAGE TO DATA ARISING OUT O...

Отзывы: