D15335.08 Cisco TelePresence MX700 and MX800 API Reference Guide CE9.2, NOVEMBER 2017.
Copyright © 2017 Cisco Systems, Inc. All rights reserved.
116
Cisco TelePresence MX700 and MX800
API Reference Guide
xCommand Audio Volume Unmute
Set the volume on the endpoint back on after muting.
Requires user role: ADMIN, USER
USAGE:
xCommand Audio Volume Unmute
xCommand Audio VuMeter Start
Start a VU meter to show the audio signal level on the specified connector. You have to specify
both the connector's type and number (ConnectorType, ConnectorId) to uniquely identify the
connector. The VU meter measures the input level for frequencies below 20 kHz.
Requires user role: ADMIN, USER
USAGE:
xCommand Audio VuMeter Start ConnectorID:
ConnectorID
ConnectorType:
ConnectorType
[IncludePairingQuality:
IncludePairingQuality
]
where
ConnectorID:
Integer (1..8) for Microphone; Integer (1..4) for Line; Integer (1..3) for HDMI
Select a connector number. Together with the ConnectorType it uniquely identifies the
connector.
ConnectorType:
HDMI/Line/Microphone
Select the connector type.
IncludePairingQuality:
Literal (Off / On )
The default is set to Off
xCommand Audio VuMeter Stop
Stop the VU meter on the specified connector. You have to specify both the connector's type
and number (ConnectorType, ConnectorId) to uniquely identify the connector.
Requires user role: ADMIN, USER
USAGE:
xCommand Audio VuMeter Stop ConnectorID:
ConnectorID
ConnectorType:
ConnectorType
where
ConnectorID:
Integer (1..8) for Microphone; Integer (1..4) for Line; Integer (1..3) for HDMI
Select a connector number. Together with the ConnectorType it uniquely identifies the
connector.
ConnectorType:
HDMI/Line/Microphone
Select the connector type.
xCommand Audio VuMeter StopAll
Stop all VU meters.
Requires user role: ADMIN, USER
USAGE:
xCommand Audio VuMeter StopAll
Introduction
About the API
xConfiguration
Appendices
xCommand
xStatus
xCommand