Installing the Tap Housing on a Strand
4013399 Rev C
23
Installing the Tap Housing on a Strand
The strand-mounted configuration has the feeder cable entering one side of the unit
and exiting the other side. The unit has one strand clamp with a strand clamp bolt
and uses a standard cable strand for mounting.
To Install the Tap Housing on a Strand
Follow these steps to install a tap housing on a strand.
1
Begin this procedure with the faceplate removed. Refer to
To Remove the
Faceplate
(on page 20).
2
Using a 3/8-in. wrench, loosen the strand clamp bolt.
3
Attach the housing to the strand making sure that the strand enters the strand
clamp.
4
Secure the strand clamp to the strand by tightening the strand clamp bolt with a
3/8-in. wrench from 30 in-lb to 40 in-lb (3.4 Nm to 4.5 Nm).