Chapter 4 Installation and Maintenance
Power Supply Overview
Cisco SCE 2000 4/8xFE Installation and Configuration Guide
OL-7826-05
4-13
Refer to the following tables for LED status information
Table
4-4
IN LED Status for AC-input and DC-input Power Supply Units
LED State
Power Supply Unit Condition
On (green)
The input voltage is in the required range.
Off
The input voltage is not in the required range.
Table
4-5
OK LED Status for AC-input and DC-input Power Supply Units
LED State
Power Supply Unit Condition
On (green)
The output voltage is in the required range (between 11.9 and 12.1 VDC).
Off
The output voltage is not within the required range. (is greater than 12.1
VDC or less than 11.9 VDC)
Table
4-6
Power LED (on front panel) Status for AC-input and DC-input Power Supply
Units
LED State
Power Supply Unit Condition
Continuous green
Corresponding power supply unit is present and functioning normally
Red
Corresponding power supply unit present, but malfunctioning
Unlit
Corresponding power supply unit is either not present or has failed.
Note
Simple Network Management Protocol (SNMP) monitors the activity of the power supplies. In most
cases when a power supply problem occurs, an SNMP trap is sent in SNMP and the appropriate
message is posted on the
SCE 2000