Cisco PVDM2-12DM, PVDM2-24DM, and PVDM2-36DM Digital Modem Packet Voice Data Modules
How to Configure Digital Modem PVDM2s
19
Cisco IOS Release 12.4(9)T, 12.4(11)XW, and 12.4(20)T
DETAILED STEPS
Configuration Using HWIC-xCE1T1-PRI
To configure T1/E1HWICs for PRI operation, perform the following tasks:
SUMMARY STEPS
1.
network-clock-participate
[
slot
slot-number
|
wic
wic-slot
]
2.
controller
{
t1
|
e1
}
slot
/
subslot
/
port
3.
framing
{
sf
|
esf
}
or
framing
{
crc4
|
no-crc4
}
4.
linecode
{
ami
|
b8zs
}
or
linecode
{
ami
|
hdb3
}
5.
pri-group
timeslot-range
DETAILED STEPS
Command or Action
Purpose
Step 1
ds0-group
group-number
timeslots
list
type
type
Example:
Router(config)# ds0-group 1 timeslots 1-24 type
e&m-immediate-start
Specifies the DS0 time slots that make up a port.
list
specifies the time slots that are included in the DS0
group. For T1 ports, time slots range from 1 to 24. For E1
ports, time slots range from 1 to 31.
Refer to Cisco IOS Release 12.4 Master Commands List for
a complete listing of supported signaling methods.
Command or Action
Purpose
Step 1
network-clock-participate
[
slot
slot-number
|
wic
wic-slot
]
Example:
Router(config)# network-clock-participate wic 0
TDM group configuration only. Allows the ports on a
specified network module or interface card to use the
network clock for timing.
Step 2
controller
{
t1
|
e1
}
slot
/
subslot
/
port
Example:
Router(config)# controller t1 1/0
Enters controller configuration mode.