background image

4008226 Rev B 

 

 

Prisma EtherLinX Unit Installation 
Instructions 

Overview 

Introduction 

The Prisma

®

 EtherLinX

 unit enables service providers to offer differentiated data 

networking or virtual private network (VPN) services to multi-tenant building and 
business customers. Residing at the customer premises or at the service provider 
point of presence (POP), the Prisma EtherLinX unit provides a VLAN-based Layer 2 
entry point to the metropolitan area network (MAN) fiber network, trunking, 
differentiating and separating customer traffic.  Featuring SNMP management, 
bandwidth control, quality of service (QoS), traffic prioritization, and multicast 
pruning (using IGMP v1, v2), it is an ideal solution for delivering Ethernet-based 
services to customers quickly and cost-effectively.  The Prisma EtherLinX unit also 
features Telnet, and firmware upgrading through serial configuration or Telnet via a 
TFTP server. 

 

Purpose 

These installation instructions provide product information and instructions for 
installing the Prisma EtherLinX

 

unit. 

 

Continued on next page 

Содержание Prisma EtherLinX

Страница 1: ... to the metropolitan area network MAN fiber network trunking differentiating and separating customer traffic Featuring SNMP management bandwidth control quality of service QoS traffic prioritization and multicast pruning using IGMP v1 v2 it is an ideal solution for delivering Ethernet based services to customers quickly and cost effectively The Prisma EtherLinX unit also features Telnet and firmwa...

Страница 2: ...sonal injury or equipment damage may occur In These Installation Instructions These installation instructions contain the following topics Topic See Page Important Safety Instructions 3 Laser Safety 13 Product Description 16 Prisma EtherLinX Unit Installation Instructions 17 Software Configurable Features 19 About PrismaView Software 21 SNMP Management 22 Device Specific Configuration 28 Fiber Opt...

Страница 3: ... find this symbol in the document that accompanies this product This symbol indicates important operating or maintenance instructions You may find this symbol affixed to the product This symbol indicates a live terminal where a dangerous voltage may be present the tip of the flash points to the terminal device You may find this symbol affixed to the product This symbol indicates a protective groun...

Страница 4: ...ence of moisture the proximity to ground potential and the possibility that hazardous voltages may be present on network connected cables there is a greater risk of electric shock when working with electronic equipment in the outdoor environment To minimize the likelihood and effect of electric shock follow the instructions in this warning and the precautions below WARNING To reduce risk of electr...

Страница 5: ...llowing Place this equipment close enough to a mains AC outlet to accommodate the length of this equipment s power cord Route all power cords so that people cannot walk on place objects on or lean objects against them This may pinch or damage the power cords Pay particular attention to power cords at plugs outlets and the points where the power cords exit this equipment Make sure the mounting surf...

Страница 6: ...ions On a bed sofa rug or similar surface Over a radiator or a heat register In an enclosure such as a bookcase or equipment rack unless the installation provides proper ventilation Handling Precautions When moving a cart that contains this equipment check for any of the following possible hazards WARNING Avoid personal injury and damage to this equipment Move any equipment and cart combination wi...

Страница 7: ...nnect the power cord from the grounded mains electrical outlet and disconnect the antenna or cable system under the following circumstances During lightning storms or When you are not using this equipment for an extended period Ground your antenna system to provide some protection against voltage surges and built up static charge Power Sources WARNING Avoid electric shock and fire hazard Do not ov...

Страница 8: ... the third terminal is provided for safety Do not defeat the safety purpose of the grounding type or polarized safety plug To properly ground this equipment follow these safety guidelines Grounding Type Plug For a 3 terminal plug one terminal on this plug is a protective grounding pin insert the plug into a grounded mains 3 terminal outlet Note This plug fits only one way If this plug cannot be fu...

Страница 9: ...power cord to the mains supply outlet No connection to the protective ground is required as this class of equipment is provided with double or reinforced and or supplementary insulation in addition to the basic insulation provided in Class I equipment Note Class II equipment which is subject to EN 50083 1 is provided with a chassis mounted equipotential bonding terminal See the section titled Equi...

Страница 10: ... equipment ask the service technician to perform safety checks to determine that the equipment is in proper operating condition CAUTION Avoid damage to this equipment Adjust only what the operating instructions describe Improper adjustment of controls may result in damage that may require extensive corrective work by qualified service personnel Replacement Parts When replacement parts are required...

Страница 11: ...lding Exceptions from this general rule will be clearly stated in the connector description for the excepted connector in question Ethernet cables should be of single shielded or double shielded type Coaxial cables should be of the double braided shielded type EMC Where this equipment is subject to USA FCC and or Industry Canada rules the following statements apply FCC Statement for Class A Equipm...

Страница 12: ...o operate this equipment Modifications have the potential to degrade the level of protection built into this equipment putting people and property at risk of injury or damage Those persons making any modifications expose themselves to the penalties arising from proven non compliance with regulatory requirements and to civil litigation for compensation in respect of consequential damages or injury ...

Страница 13: ... the fiber is unmated or unterminated Do not stare into an unmated fiber or at any mirror like surface that could reflect light that is emitted from an unterminated fiber Do not view an activated fiber with optical instruments e g eye loupes magnifiers microscopes Use safety approved optical fiber cable to maintain compliance with applicable laser safety requirements Warning Fiber Optic Cables WAR...

Страница 14: ...can pose a hazard to remotely located personnel when operated without their knowledge Allow only personnel trained in laser safety to operate this software Otherwise injuries to personnel may occur Restrict access of this software to authorized personnel only Install this software in equipment that is located in a restricted access area Laser Safety Information This laser based multi mode transcei...

Страница 15: ...Specific Laser Information The following illustration displays the location of the laser apertures on this module s front panel The following label is on the module Class 1 Laser product Luokan 1 Laserlaite Laser Klasse 1 Appareil A Laser de Classe 1 ...

Страница 16: ...s one Uplink port either 100Base FX fiber or 10 100 twisted pair four 10 100 twisted pair Ethernet downlink ports for connecting users LANs and an internal 100 240 10 AC power supply Prisma EtherLinX Unit Illustration Refer to the following illustration for a view of the Prisma EtherLinX unit ...

Страница 17: ...device that is to be interconnected 3 Plug the unit into a reliable filtered power source Wall Mount Installation Follow these steps to wall mount the Prisma EtherLinX unit 1 Attach the wall mount bracket to the Prisma EtherLinX unit using the supplied screws Screw holes for mounting unit to wall Wall mount bracket must be attached to the unit Screw holes for mounting wall mount bracket to unit wi...

Страница 18: ...Twisted pair Connection All twisted pair ports on the Prisma EtherLinX unit include AutoCross a feature which automatically selects between a crossover workstation or pass through connection depending on the connected device Note Since single strand fiber products use optics that transmit and receive on two different wavelengths you must deploy single strand fiber products in pairs or connect two ...

Страница 19: ...ere in the fiber loop Using FiberAlert a local site administrator is notified of a fault and can quickly determine where a cable fault is located Note FiberAlert is not available applicable on single strand fiber products Auto Negotiation Duplex Mode and Speed The twisted pair ports on the Prisma EtherLinX unit auto negotiate for speed and duplex mode This device can also selectively advertise or ...

Страница 20: ...uplex mode are desired it is recommended that you use Selective Advertising rather than Force Mode when connecting to devices that ONLY auto negotiate Bandwidth Control The Prisma EtherLinX unit includes bandwidth control functionality You can independently set bandwidth in 32 Kbps increments on each downlink port or you can set the bandwidth for the unit by assigning the uplink port a given amoun...

Страница 21: ...can perform include setting the IP address subnet mask and default gateway defining the community strings and SNMP traps In addition to the above functions iConfig offers an authorized IP address system and access restriction to Management Information Base MIB groups supported by our manageable devices These extra layers of security are purely optional and do not affect SNMP compatibility in any w...

Страница 22: ...configuration e g you can select which traps to assign with iConfig After assigning the Prisma EtherLinX unit an IP address you can use PrismaView software or another SNMP compatible Network Management System NMS to remotely configure monitor and manage the Prisma EtherLinX unit About Serial Port Configuration Although the Prisma EtherLinX unit does not include a DB 9 serial port you can use the s...

Страница 23: ...elf test the screen displays the following message Press Enter for Device Configuration Press Enter to go to the Main Configuration screen Here you will find several displays Saved Values displays changes made during current session IP Address MUST be assigned during initial configuration Subnet Mask MUST be assigned during initial configuration Default Gateway Server IP Addr TFTP server New Prom ...

Страница 24: ...n screen or turn the chassis power OFF then ON again Because a Delete key is not available on VT 100 terminal emulators use the F2 key Assigning TCP IP Information Follow these steps to modify the Saved Parameter Values i e assign IP address and subnet mask 1 From the Main Configuration screen press I 2 Enter the IP address for the connected device and press Enter 3 Enter the subnet mask for the c...

Страница 25: ...spaces and press Enter 3 Type one of the following to assign the community string s access rights R read only access W read write access Enter abort 4 Press Enter 5 Type reboot for changes to take effect Result The Saved Values and Current Values should now both display the changes made e g new IP address and subnet mask Deleting Community Strings Follow these steps to delete all community strings...

Страница 26: ... Start and Authentication Failure When deployed in pairs the Prisma FiberLinX module also supports the following traps Remote Unit Lost Remote Unit Back Online Far End TX Link On and Far End TX Link Off Removing Trap Destinations Follow these steps to remove all trap destinations 1 From the Main Configuration screen press K 2 Press Y to continue when asked if you really want to remove all trap des...

Страница 27: ...are NOT allowed and press Enter Note Passwords are case sensitive Result You will then be asked for your password whenever you log on or off Removing Password Protection Follow these steps to remove password protection 1 From the Main Configuration screen press P 2 Press Enter Ending Your Session From the Main Configuration screen press E before disconnecting the cable in order to stop the continu...

Страница 28: ... document reboot Reboots the unit security Allows ARP request configuration accounts Allows addition deletion of Username Password accounts Administrators must maintain a password list port Displays port status values and allows some configuration Refer to Port Configuration later in this document dlSecure Downlink ports are isolated from one another i e there is no communication between downlink ...

Страница 29: ...figure VLAN IDs 1 From the Command List section of the Main Configuration screen serial configuration press the Space Bar 2 Type vlan and press Enter for VLAN Configuration 3 Decide whether the unit will be in dlSecure mode or dl_Open mode Configure as desired and reboot Use dl_Open to configure multiple VLAN IDs on multiple ports Refer to Device Specific Configuration earlier in this document If ...

Страница 30: ...ion screen The high and low priority is determined by the Base VLAN of the unit Use the PrismaView software to set the Base VLAN priority this value is not configurable via a serial Telnet session dl_Open Mode Configuring Multiple VLAN IDs Per Port Make sure to configure the unit for dl_Open mode and reboot the unit Upon enabling VLAN functionality the following screen appears When using dl_Open m...

Страница 31: ...w priority traffic Via the PrismaView software you can set a Base VLAN Priority to designate what will be high priority and low priority If the Base VLAN Priority is 4 0 3 are low priority and 4 7 are high priority If you change the Base VLAN Priority to 3 0 2 are low priority and 3 7 are high priority In the VLAN Configuration screen shown above enter a Priority 0 7 for each port and SNMP if desi...

Страница 32: ...r to start downloading the file If the download is interrupted do not reset the module or reboot the chassis Close the session and then open a new TFTP session Port Configuration The Prisma EtherLinX unit allows you to configure the ports via serial configuration you can also configure the ports via the PrismaView software Type ports and press Enter to be taken to the Port Configuration screen In ...

Страница 33: ... DHCP client in the Prisma EtherLinX unit By default the DHCP client is disabled If a DHCP server is present on the network the DHCP client initiates a dialogue with the server during the boot up sequence The server will then issue an IP address Default Gateway and Subnet mask to the Prisma EtherLinX unit chassis Once the new IP address is received the Prisma EtherLinX unit reboots so that the new...

Страница 34: ...Inspect connectors after cleaning to confirm that they are clean and undamaged Recommended Equipment CLETOP or OPTIPOP ferrule cleaner CLETOP Type A for SC Type B for LC Compressed air also called canned air Lint free wipes moistened with optical grade 99 isopropyl alcohol Bulkhead swabs for LC or SC type connectors choose appropriate type Compressed air also called canned air Tips for Optimal Fib...

Страница 35: ... light that is emitted from an unterminated fiber Use safety approved optical fiber cable to maintain compliance with applicable laser safety requirements Important Ensure that no optical power is present prior to this procedure 1 Turn optical power off to the connector 2 Using an optical connector scope inspect the connector for scratches burns or other signs of damage Note If the connector is da...

Страница 36: ...X module Prisma EtherLinX Unit LEDs The Prisma EtherLinX unit contains the following LEDs Uplink and Downlink Port LEDs Description LNK ACT Glows green when link is established on port Blinks green during data activity on port FDX COL Glows amber when port is operating in Full Duplex Blinks amber when collisions occur on port ...

Страница 37: ...hi sciatl com Korea Korea Telephone 82 2 3429 8800 Fax 82 2 3452 9748 E mail kelly song sciatl com China mainland China Telephone 86 21 2401 4433 Fax 86 21 2401 4455 E mail xiangyang shan sciatl com All other Asia Pacific countries Australia Hong Kong Telephone 852 2588 4746 Fax 852 2588 3139 E mail support apr sciatl com Brazil Brazil For Technical Support call Telephone 55 11 3845 9154 ext 230 F...

Страница 38: ...trademarks or trademarks of Cisco Systems Inc and or its affiliates in the U S and certain other countries All other trademarks mentioned in this document are the property of their respective owners Product and service availability are subject to change without notice 2009 Cisco Systems Inc All rights reserved Printed in United States of America March 2009 Part Number 4008226 Rev B ...

Отзывы: