![Cisco PA-VXA Series Скачать руководство пользователя страница 77](http://html.mh-extra.com/html/cisco/pa-vxa-series/pa-vxa-series_installation-and-configuration-manual_64411077.webp)
4-27
T1/E1 Digital Voice Port Adapter Installation and Configuration
OL-3592-02
Chapter 4 Configuring the PA-VXA, PA-VXB, and PA-VXC
Configuring Voice over IP
Validation Tips
You can check the validity of your voice-port configuration by performing the following tasks:
•
Pick up the handset of an attached telephony device and check for a dial tone.
•
If you have a dial tone, check for DTMF detection. If the dial tone stops when you dial a digit, then
the voice port is most likely configured properly.
•
Use the show voice-port command to verify that the data configured is correct.
Troubleshooting Tips
If you are having trouble connecting a call and you suspect the problem is associated with voice-port
configuration, you can try to resolve the problem by performing the following tasks:
•
Ping the associated IP address to confirm connectivity. If you cannot successfully ping your
destination, refer to the Network Protocols Configuration Guide, Part 1.
•
Use the show voice-port command to make sure that the port is enabled. If the port is offline, use
the no shutdown command.
•
If you have configured E&M interfaces, make sure that the values pertaining to your specific PBX
setup, such as timing or type, are correct.
•
Check to see if the voice network module has been correctly installed. For more information, refer
to the installation document that came with your voice network module.
Fine-Tune E&M Voice Ports
Depending on the specifics of your particular network, you may need to adjust voice parameters
involving timing, input gain, and output attenuation for E&M voice ports. Collectively, these commands
are referred to as voice-port tuning commands.
Note
In most cases, the default values for voice-port tuning commands are sufficient.
Step 6
connection plar string
(Optional.) Specify the Private Line Auto Ringdown (PLAR)
connection if this voice port is used for a PLAR connection. The
string value specifies the destination telephone number.
Step 7
music-threshold number
(Optional.) Specify the threshold (in decibels) for on-hold music.
Valid entries are from –70 dB to –30 dB.
Step 8
description string
(Optional.) Attach descriptive text about this voice-port
connection.
Step 9
comfort-noise
(Optional.) Specify that background noise will be generated.
Command
Purpose