31
Installing the Cisco ONS 15216-MD-40-ODD and 15216-MD-40-EVEN Mux/Demux Patch Panels
78-19053-01
Patch Panel Specifications
Insertion Loss
1
BOL
(Beginning of life) -
DEMUX module
•
any state of
polarization
(SOP) and
within
operative
temperature
range
•
within
operating
bandwidth
•
including
connectors
4.0
6.0
dB
Insertion Loss BOL
(Beginning of life) -
MUX module
4.0
6.0
dB
Insertion Loss EOL
(End of life)
4.0
6.5
dB
Insertion Loss
Uniformity
2
1.5
dB
Adjacent Channel
Isolation
3
DEMUX
•
any state of
polarization
(SOP) and
within
operative
temperature
range
•
within
operating
bandwidth
20.0
dB
Non-Adjacent Channel
Isolation
4
DEMUX
30.0
dB
Total Crosstalk
DEMUX
16.0
dB
Adjacent Channel
Isolation MUX
•
any state of
polarization
(SOP) and
within
operative
temperature
range
•
within
operating
bandwidth
17.0
dB
Non-Adjacent Channel
Isolation MUX
30.0
dB
Total Crosstalk MUX
14.0
dB
Parameter Condition
Min
Max
Units