21
Installing the Cisco ONS 15216-MD-40-ODD and 15216-MD-40-EVEN Mux/Demux Patch Panels
78-19053-01
Installation
When cleaning a paired cable connector (bulkhead mating adapter), always clean
the mating adapter first.
If properly maintained (only used with clean, defect-free fiber connectors and
capped when not in use), the mating adapter would not require cleaning. However,
if you suspect the adapter is dirty, clean it by using the CLETOP stick swab.
Note
For multi-fiber cable assemblies, use specific cleaning tools or materials designed
for the assembly type.
Clean the Bulkhead Mating Adapters
Step 1
Read the manufacturer (cleaning cartridge) instructions to insert the cartridge
cleaning tip into the mating adapter.
Step 2
Slide the lever on the cartridge to swipe the mating surface.
Note
Always keep unused adapter ports and fiber connectors capped with a
clean dust cap.
Clean Fiber-Optic Cable Connectors
The tools required to clean fiber connectors are:
•
Inspection microscope
•
Type A Fiber Optic Connector Cleaner (CLETOP reel)
•
Optical swab
•
Optical receiver cleaning stick
Step 1
Using an inspection microscope, inspect each fiber connector for dirt, cracks, or
scratches.
Step 2
Replace any damaged fiber connectors.