29
Installing the Cisco ONS 15216-MD-40-ODD and 15216-MD-40-EVEN Mux/Demux Patch Panels
78-19053-01
Patch Panel Specifications
Step 4
Disconnect the inventory USB cable releasing it from the USB cable clamp and
from the USB receptacle. (See
Step 5
Open the cable retention clips of the fiber bend radius controllers. (See
.)
Step 6
Remove the fibers and the cable.
Step 7
Close the cable retention clips.
Step 8
Insert the drawer. (See
Step 9
Close the front panel. (See
Step 10
Disconnect the ground lug. (See
.)
Step 11
Undo the mounting screws and remove the patch panel from the rack.
Patch Panel Specifications
This section contains environmental, optical, and mechanical specifications for
the patch panel.
Environmental Specifications
provides the environmental specifications for the patch panel.
Table 4
Environmental Performance Specifications
Environmental Condition
MIN
MAX
Units
Short Term (96 hours/year) Temperature
Range (STR)
-5
55
Celsius
23
131
Fahrenheit
Continuous Operative Temperature
Range (OTR)
0
50
Celsius
32 122
Fahrenheit
Power Handling for the Optical Port
300
mW
Power Handling for the USB Port
400
600
mW