• 1100-W HVAC/HVDC power supply with port-side exhaust airflow (blue coloring)
(NXA-PHV-1100W-PE)
• 1100-W HVAC/HVDC power supply with port-side intake airflow (burgundy coloring)
(NXA-PHV-1100W-PI)
• 1100-W DC power supply with port-side exhaust airflow (blue coloring) (NXA-PDC-1100W-PE)
• 1100-W DC power supply with port-side intake airflow (burgundy coloring) (NXA-PDC-1100W-PI)
Both power supplies use the same type of power source. Do not mix AC and DC
power sources.
Note
All fan modules and power supplies must use the same airflow direction during
operations.
Note
In the event that only one power supply is operating in an active system and a
second power supply is inserted, the system fan will slow down to
50% of Max
speed
for 12 seconds. It can take up to 10 seconds for the second power supply
to become active. Please do not remove the first power supply during this
time-frame, in order to avoid system shutdown.
Note
The following figure shows the hardware features seen from the port side of the chassis.
Figure 1: Port Side View of the Cisco Nexus 9316D-GX Switch
Lane selector LEDs
3
Chassis LEDs (Beacon [BCN], Status [STS], and
Environment [ENV])
1
Cisco Nexus C9316D-GX ACI-Mode Switch Hardware Installation Guide
2
Overview
Overview
Содержание Nexus C9316D-GX
Страница 2: ... 2017 Cisco Systems Inc All rights reserved ...
Страница 6: ...Cisco Nexus C9316D GX ACI Mode Switch Hardware Installation Guide vi Contents ...
Страница 50: ...Cisco Nexus C9316D GX ACI Mode Switch Hardware Installation Guide 42 LEDs LEDs ...
Страница 52: ...Cisco Nexus C9316D GX ACI Mode Switch Hardware Installation Guide 44 Additional Kits Additional Kits ...