Status
Color
LED
All diagnostics passed. This module is operational (normal
initialization sequence).
Green
STS
Indicates one of the following:
• The module has detected a slot ID parity error and will not power
on or boot up.
• The module is not fully inserted, and it is not making a reliable
connection with the supervisor.
• The module has failed diagnostic tests and has powered down.
• An overtemperature condition has occurred. A major temperature
threshold has been exceeded during environmental monitoring.
Flashing red
Indicates one of the following:
• The module is booting up or initializing.
• The module is resetting and both ejector levers are out.
• The module has been inserted during the initialization process.
• The module could not power up because of insufficient power.
Flashing amber
The module is not receiving power.
Off
The port is active (the link is connected and active).
Green
Link (for
each port)
The operator has disabled the port or is not initializing.
Orange
Beacon is enabled for the port. Or the port is faulty and disabled.
Flashing orange
The port is not active or the link is not connected.
Off
Power Supply LEDs
The power supply LEDs are located on the upper left front portion of the module. The following table describes
the possible states for each of these LEDs.
Status
FAIL or FAIL/ID
LED
OK LED
Power supply is on and outputting power to the switch.
Off
Green
Power supply is connected to an AC power source but not outputting power
to the switch. The power supply may not be properly installed in the chassis.
Off
Flashing
green
Either all the installed power supplies are not receiving power or an
uninstalled power supply is not receiving power.
Off
Off
Cisco Nexus 9516 NX-OS Mode Switch Hardware Installation Guide
109
LEDs
Power Supply LEDs