C H A P T E R
6
Replacing or Installing Modules, Fan Trays, and
Power Supplies
•
Preventing Electrostatic Damage, on page 61
•
Installing or Replacing a Supervisor Module, on page 61
•
Installing or Replacing a System Controller Module, on page 65
•
Installing or Replacing a Line Card, on page 67
•
Replacing a Fan Tray, on page 70
•
Replacing a Fabric Module, on page 73
•
Installing or Replacing Power Supplies, on page 82
•
Preventing Electrostatic Damage
To prevent electrostatic damage (ESD) to electronic components, you must be sure that you are grounded
while handling electronic components. Components include, but are not limited to all switch modules.
Before you begin
The switch must be connected to the facility earth ground.
Step 1
Attach an ESD wristband to your arm and be sure that it touches your skin.
Step 2
Attach the alligator clip on the other end of the strap to the grounding cable for the switch.
Step 3
Verify that the grounding cable is attached to the facility earth ground.
Installing or Replacing a Supervisor Module
The switch can operate with one or two supervisor modules that are installed in the chassis.
Cisco Nexus 9516 NX-OS Mode Switch Hardware Installation Guide
61