Port-Side Exhaust Airflow Coloring
Port-Side Intake Airflow Coloring
Replaceable Modules
Blue
Burgundy
Fans
Blue
Burgundy
AC power supplies
White
HVAC/HVDC power supplies
Blue
Burgundy
DC power supplies
The fan and power supply modules are field replaceable. You can replace one fan module or one power supply
module during operations, so long as the other installed modules are operating. If you have only one power
supply that is installed, you can install the replacement power supply in the open slot before removing the
original power supply.
Fan and power supply modules must have the same direction of airflow. Otherwise, the switch can overheat
and shut down. If you are installing a dual-direction power supply, that module automatically uses the same
airflow direction as the other modules in the switch.
Note
If the switch has port-side intake airflow (burgundy coloring for fan modules), you must locate the ports in
the cold aisle. If the switch has port-side exhaust airflow (blue coloring for fan modules), you must locate the
ports in the hot aisle. If you locate the air intake in a hot aisle, the switch can overheat and shut down.
Caution
The switch supports the Fabric Extenders (FEXs) listed at
https://www.cisco.com/c/dam/en/us/td/docs/switches/
datacenter/nexus9000/hw/interoperability/fexmatrix/fextables.html
Cisco Nexus 93240YC-FX2 NX-OS Mode Switch Hardware Installation Guide
5
Overview
Overview
Содержание N9K-C93240YC-FX2
Страница 6: ...Cisco Nexus 93240YC FX2 NX OS Mode Switch Hardware Installation Guide vi Contents ...
Страница 16: ...Cisco Nexus 93240YC FX2 NX OS Mode Switch Hardware Installation Guide 6 Overview Overview ...
Страница 70: ...Cisco Nexus 93240YC FX2 NX OS Mode Switch Hardware Installation Guide 60 LEDs LEDs ...
Страница 74: ...Cisco Nexus 93240YC FX2 NX OS Mode Switch Hardware Installation Guide 64 Additional Kits Vent Bracket ...