2-51
Cisco MGX 8230 Edge Concentrator Installation and Configuration
Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001
Chapter 2 Module and Service Descriptions
Frame Relay Service Modules
E3 Interfaces
•
One G.703 (34.368 Mbps +/-20 ppm) interface with dual female 75-ohm BNC coaxial connectors
per port (separate RX and TX)
•
HDB3 line coding
•
Pulse shape conforming to ITU G.703
•
E3 BERT and extended loop-up, loop-down pattern generation and verification
•
1:1 redundancy with Y-cabling for E3 CESM cards of the same type
•
LOS alarm detection/generation support
•
Transmitter loop-timed to receiver or synchronized to shelf
LED Indicators
Table 2-14 LED Indicators for T3/E3 CESM
Type of LED
Color
Meaning
ACT LED (Active)
Green
On indicates the card set is in active mode.
STBY LED (Standby)
Yellow
•
Slow blink with the Active LED off indicates the card is
in the boot state.
•
Fast blink with the Standby LED indicates the receiving
firmware.
•
Fast blink indicates the service module is passing BRAM
channel information to the PXM1.
•
Steady yellow indicates the card is in Standby mode and
the firmware is executing ADMIN code.
FAIL LED
Red
•
Steady red with Active and Standby LEDs off indicates
either the card is in the Reset condition, the card has
failed, or the card set is not complete (no line module).
•
Steady red with Active LED on indicates the card was
active prior to failing.
•
Steady red with Standby LED on indicates the card was
standby prior to failing.
•
Both standby and red LED lit indicates self-test failure.
PORT LEDs
Green
Green indicates the port is active.
Red
Red indicates a local alarm on the port.
Yellow
Yellow indicates a remote alarm on the port.