A-12
Cisco MGX 8230 Edge Concentrator Installation and Configuration
Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001
Appendix A Technical Specifications
FRSM-HS2 Specifications
FRSM-2T3E3 E3 Line
For characteristics of the line on an FRSM-2T3E3 with an E3 back card see figure A14:
E3 Framer Level
For line framing, the E3 operation of the FRSM-2T3E3 complies with
ITU-T
G.751.
FRSM-2T3E3 Line Alarms
For line alarms, the FRSM-2T3E3 supports:
•
Detection and generation of Remote Alarm Indicator (RAI) signal (also known as FERF and Yellow
signal)
•
Detection and generation of Alarm Indication Signal (AIS)
•
Detection of Out of Frame (OOF) condition
•
Detection of Loss of Frame (LOS) condition
•
Automatic generation of Far End Block Error (FEBE)
Statistics and Counter Specifications
See the section titled “
Counters and Statistics for FRSM-2CT3, FRSM-2T3E3, and FRSM-HS2
” for lists
of applicable statistics and counters.
FRSM-HS2 Specifications
The FRSM-HS2 is the Frame Relay module with two HSSI ports. The topics in this section are:
•
Transport technology standards with which the card complies (
Table A-15
)
•
General physical attributes of the card, such as LEDs on the faceplate (
Table A-16
)
•
Line and framer characteristics (
Table A-17
)
Table A-14 E3 Line Level
Feature
Significance or Value
Number of E3 Lines
Two
Line Interface Connector
75 ohm BNC
Line Rate
34.368 Mbps +/- 20 ppm
Line Coding
HDB3
Transmit Timing
Normal or Loop timed
Input Jitter Tolerance
Per ITU-T G.823
Output Jitter
0.05 UI maximum with jitter-free input clock per AT&T TR54014
Output Pulse
Per ITU-T G.703