8-9
Cisco ME 3400 Ethernet Access Switch Software Configuration Guide
OL-9639-07
Chapter 8 Configuring IEEE 802.1x Port-Based Authentication
Understanding IEEE 802.1x Port-Based Authentication
To configure VLAN assignment you need to perform these tasks:
•
Enable AAA authorization by using the
network
keyword to allow interface configuration from the
RADIUS server.
•
Enable IEEE 802.1x. (The VLAN assignment feature is automatically enabled when you configure
IEEE 802.1x on an access port).
•
Assign vendor-specific tunnel attributes in the RADIUS server. The RADIUS server must return
these attributes to the switch:
–
[64] Tunnel-Type = VLAN
–
[65] Tunnel-Medium-Type = 802
–
[81] Tunnel-Private-Group-ID = VLAN name or VLAN ID
Attribute[64] must contain the value
VLAN
(type 13). Attribute[65] must contain the value
802
(type
6). Attribute[81] specifies the
VLAN name
or
VLAN ID
assigned to the IEEE 802.1x-authenticated
user.
For examples of tunnel attributes, see the
“Configuring the Switch to Use Vendor-Specific RADIUS
Attributes” section on page 7-29
.
802.1x Switch Supplicant with Network Edge Access Topology (NEAT)
NEAT extends identity to areas outside the wiring closet (such as conference rooms) through the
following:
•
802.1x switch supplicant: You can configure a switch to act as a supplicant to another switch by
using the 802.1x supplicant feature. This configuration is helpful in a scenario where, for example,
a switch is outside a wiring closet and is connected to an upstream switch through a trunk port. A
switch configured with the 802.1x switch supplicant feature authenticates with the upstream switch
for secure connectivity.
•
Host Authorization: NEAT ensures that only traffic from authorized hosts (connecting to the switch
with supplicant) is allowed on the network. The switches use Client Information Signalling Protocol
(CISP) to send the MAC addresses connecting to the supplicant switch to the authenticator switch,
as shown in
Figure 8-4
.
•
Auto enablement: Automatically enables trunk configuration on the authenticator switch, allowing
user traffic from multiple VLANs coming from supplicant switches. This can be achieved by
configuring the cisco-av-pair as
device-traffic-class=switch
at the ACS. (You can configure this
under the
group
or
user
settings.)
Содержание ME 3400 Series
Страница 40: ...Contents xl Cisco ME 3400 Ethernet Access Switch Software Configuration Guide OL 9639 07 ...
Страница 44: ...xliv Cisco ME 3400 Ethernet Access Switch Software Configuration Guide OL 9639 07 Preface ...
Страница 1138: ...Index IN 52 Cisco ME 3400 Ethernet Access Switch Software Configuration Guide OL 9639 07 ...