Design Specification
Description
5% — 95% non-condensing
Humidity
Table 8: Environmental Tests
Design Specification
Description
IEC 61850-3, IEEE 1613
Vibration
Half Sine (operating)
Duration = <2 ms
Velocity = 2.39 m/s
Number of shocks: A series of 6 shocks, one on each side.
IEEE 1613 and IEC61850-3
NUP T2 shock testing, non-NEBS 3396
Shock
Table 9: Certifications
Design Specification
Description
UL 60950-1, 2nd edition
CAN/CSA C22.2 No. 60950-1, 2nd edition
EN 60950-1, 2nd edition
CB to IEC 60950-1, 2nd edition with all group differences and national deviations
Standard Safety Certifications
EN55022/CISPR22, CFR 47 Part 15, ICES003, VCCI-V-3, AS/NZS CISPR22, CNS13438, EN300-
386, EN61000-3-2, EN61000-3-3, and EN55032/CISPR32
EMC Emissions
EN55024/CISPR24, (EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6,
EN61000-4-11), EN55035/CISPR35, and EN300-386
EMC Immunity
EN 301 908-1, EN 301 908-2, EN 301 511, and EN 301 908-13
Cellular Radio
IP30 compliant when vertical and cables downward.
Compliance
EN301 489-1, EN 303 413, EN 301 489-19, EN 301 489-52, and EN 62311
Radio Immunity
Table 10: Transportation/Storage Conditions
Design Specification
Description
-40 to +85°C (–40 to +185°F)
Temperature
10 – 95%
Humidity
4570 m (15,000 ft)
Altitude
Cisco IR807 Industrial Integrated Services Router Hardware Installation Guide
42
Technical Specifications
Router Specifications