background image

Cisco IR807 Industrial Integrated Services Router Hardware Installation
Guide

First Published:

2017-11-10

Last Modified:

2018-10-12

Americas Headquarters

Cisco Systems, Inc.
170 West Tasman Drive
San Jose, CA 95134-1706
USA
http://www.cisco.com
Tel: 408 526-4000

800 553-NETS (6387)

Fax: 408 527-0883

Содержание IR800 Series

Страница 1: ...outer Hardware Installation Guide First Published 2017 11 10 Last Modified 2018 10 12 Americas Headquarters Cisco Systems Inc 170 West Tasman Drive San Jose CA 95134 1706 USA http www cisco com Tel 408 526 4000 800 553 NETS 6387 Fax 408 527 0883 ...

Страница 2: ...RSE OF DEALING USAGE OR TRADE PRACTICE IN NO EVENT SHALL CISCO OR ITS SUPPLIERS BE LIABLE FOR ANY INDIRECT SPECIAL CONSEQUENTIAL OR INCIDENTAL DAMAGES INCLUDING WITHOUT LIMITATION LOST PROFITS OR LOSS OR DAMAGE TO DATA ARISING OUT OF THE USE OR INABILITY TO USE THIS MANUAL EVEN IF CISCO OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES Any Internet Protocol IP addresses and pho...

Страница 3: ...nce with Cisco software Conventions This section describes the conventions used in this guide NOTE Means reader take note Notes contain helpful suggestions or references to additional information and material CAUTION This symbol means reader be careful In this situation you might do something that could result in equipment damage or loss of data TIP Means the following information will help you so...

Страница 4: ...bruik het nummer van de verklaring on waarschuwing als u een vertaling van de waarschuwing die bij het apparaat wordt ge raadplegen Danger BEWAAR DEZE INSTRUCTIES Danger Waarschuwing Danger TÄRKEITÄ TURVALLISUUSOHJEITA Danger Tämä varoitusmerkki merkitsee vaaraa Tilanne voi aiheuttaa ruumiillisia vammoja käsittelet laitteistoa huomioi sähköpiirien käsittelemiseen liittyvät riskit ja tutustu onne y...

Страница 5: ...styret må du være oppmerksom på farene forb elektriske kretser og kjenne til standardprosedyrer for å forhindre ulykker Bruk slutten av hver advarsel for å finne oversettelsen i de oversatte sikkerhetsadvarsl med denne enheten Danger TA VARE PÅ DISSE INSTRUKSJONENE Danger Advarsel Danger INSTRUÇÕES IMPORTANTES DE SEGURANÇA Danger Este símbolo de aviso significa perigo Você está em uma situação que...

Страница 6: ...u vara medveten om farorna med e känna till vanliga förfaranden för att förebygga olyckor Använd det nummer som fi av varje varning för att hitta dess översättning i de översatta säkerhetsvarningar som denna anordning Danger SPARA DESSA ANVISNINGAR Danger Varning Danger Cisco IR807 Industrial Integrated Services Router Hardware Installation Guide 4 Preface Safety Warnings ...

Страница 7: ...tivo Danger GUARDE ESTAS INSTRUÇÕES Danger Aviso Danger VIGTIGE SIKKERHEDSANVISNINGER Danger Dette advarselssymbol betyder fare Du befinder dig i en situation med risiko for legemesbeskadigelse Før du begynder arbejde på udstyr skal du være opmærks involverede risici der er ved elektriske kredsløb og du skal sætte dig ind i stand til undgåelse af ulykker Brug erklæringsnummeret efter hver advarsel...

Страница 8: ...Cisco IR807 Industrial Integrated Services Router Hardware Installation Guide 6 Preface Safety Warnings ...

Страница 9: ...lic network that follows the European Union standards Connecting the port to this type of public network can cause severe personal injury or can damage the unit Statement 1031 WARNING Connect the unit only to DC power source that complies with the safety extra low voltage SELV requirements in IEC 60950 based safety standards Statement 1033 WARNING For connections outside the building where the equ...

Страница 10: ...e the Full Reader Search window to search multiple PDF files simultaneously and to change case sensitivity and other options Adobe Reader s online help has more information about how to search PDF documents Obtaining Documentation and Submitting a Service Request For information on obtaining documentation submitting a service request and gathering additional information see the monthly What s New ...

Страница 11: ...egrated Services Routers Generation 2 ISR G2 Family is designed as a next generation ruggedized fixed form factor router It is a small form router with 4G for use in ATM POS Telemetry Billboards Enterprise Fleet markets Utilities and other SCADA Supervisory Control and Data Acquisition environments Hardware Overview This section covers the overview of the IR807 SKU Information Table 1 Supported SK...

Страница 12: ...ion Activity Icon Alarm Alarm Input Status Off Normal operation Red Alarm State on the Alarm Input System Power and System Status Off No power Green Steady on Normal operation Green Flashing Boot up phase or in ROM Monitor mode Amber Steady on Power is OK but possible internal FPGA program failure User Configurable LED VPN Off No VPN tunnel Steady Green At least one VPN tunnel is up RJ45 Fast Ethe...

Страница 13: ...5 sec No Service Flash on 1 sec off 1 sec Low Power Mode Flash on 5 sec off 200ms Roaming Flash on 400ms off 100ms Data Active Table 3 RSSI LEDs RSSI 0 RSSI 1 RSSI 2 RSSI Green Amber Green Green Off Off Off 110dBm On Amber Off Off 110 to 90dBm On Green Off Off 90 to 75dBm On Green On Green Off 75 to 60dBm On Green On Green On Green 60dBm Table 4 Icons only Description Icon Description Icon USB 2 0...

Страница 14: ... to 48V Alarm IN Alarm Common Fast Ethernet Ports Serial Ports Antenna 1 TNC Div Antenna 1 TNC Main Warning Figure 1 Cisco IR807 Front Panel on page 13shows the front panel details of the Cisco IR807 Cisco IR807 Industrial Integrated Services Router Hardware Installation Guide 12 Product Overview Front Panel Icons and LEDs ...

Страница 15: ...A 3 S1 DCE 1 0 S0 DTE 4 External DC Power Input and Alarm 1 1 FE0 10 100 Base T RJ 45 5 GPS SMA 6 Figure 2 Cisco IR807 Back Panel on page 13 shows the back panels details of the Cisco IR807 Figure 2 Cisco IR807 Back Panel Cisco IR807 Industrial Integrated Services Router Hardware Installation Guide 13 Product Overview Front Panel Icons and LEDs ...

Страница 16: ...imum flash memory Hardware Features This section provides an overview of the following hardware features for the Cisco 807 ISR Platform Features for Cisco IR807 The following lists the hardware platform features for the Cisco IR807 External Power Entry Nominal 12 to 48VDC Absolute 9 6 to 60VDC 4 pin 3 8 mm EURO power connector External Reset Recovery Push Button WWAN Modem Single multi band 2G 3G ...

Страница 17: ... Points Antenna Guide http www cisco com c en us td docs routers connectedgrid antennas installing combined industrial routers and industrial wireless antenna guide html Cisco Aironet Antennas and Accessories Reference Guide http www cisco com c en us products collateral wireless aironet antennas accessories product_data_sheet09186a008008883b html The following antennas and cables are available AN...

Страница 18: ...pliance ROHS compliant ANT 4G OMNI OUT N Description Cisco outdoor omnidirectional antenna for 2G 3G and 4G LTE cellular UV stable radome Mast mounting bracket Applicable for both 2G and 3G solutions Domestic LTE 700 band and global LTE 2600 band Domestic cellular and global GSM WiMAX 2300 and 2500 Electrical Specifications Frequency ranges 698 to 960 MHz 1710 to 2170 MHz and 2300 to 2700 MHz Nomi...

Страница 19: ...egrees 1710 to 2200 MHz 60 to 70 degrees 2200 to 2500 MHz and 55 to 70 degrees 2500 to 2700 MHz 3 dB beam width horizontal plane 55 to 70 degrees 698 to 960 MHz and 50 to 90 degrees 1710 to 2200 MHz F B ratio 15 dB typical 20 dB 698 to 960 MHz and 17 dB typical 23 dB 1700 to 2700 MHz Isolation 30 dB Polarization slant 45 degrees Nominal impedance 50 Ohms Radiation pattern directional Mechanical sp...

Страница 20: ...t style ceiling mount Radome PC ABS UV stable black Material substance compliance RoHS compliant Operational temperature 22 to 158 F 30 to 70 C Storage temperature 40 to 185 F 40 to 85 C Environment indoor Dimensions H x Outside dimensions 3 4 x 7 9 in 87 x 200 mm ANT 4G DP IN TNC Description Cisco indoor swivel mount dipole antenna Low profile blade style sheath Applicable for both 3G and 4G solu...

Страница 21: ...minal impedance 50 Ohms Polarization linear vertical Mechanical Specifications Radome material white black red or blue ABS UL 94 V0 Cable 4 ft RG174 VW 1 compliant Height and base diameter 90 mm and 137 mm Temperature rating 40 to 185 F 40 to 85 C Mounting 5 8 inch lug with serrated face nut 5 8 inch diameter hole through mounting surface Can be used with the following cable extensions 4G CAB ULL ...

Страница 22: ...oncelman TNC Connector It lets you directly mount the antenna to any Cisco 4G and Cisco 3G wireless Integrated Services Router ISR EHWIC with a TNC connector Cisco 4G LTE ANTM D Ominidirectional Dipole Antenna TNC Connector and Articulation Joint The threads on the connector must comply with the ANSI 7 16 28 UNEF 2B thread specification Electrical Specifications Frequency range 698 806 MHz 824 894...

Страница 23: ...nical Specifications Base material UL 94 V0PC and ABS plastic Dimensions 2 8 x 2 4 x 1 8 in 7 1 x 6 1 x 4 6 cm Weight 6 oz 0 17 kg Cable 10 ft 304 8 cm non plenum rated Pro Flex Plus 195 Modem Support The Cisco IR807 uses the WP7502 WP7504 and WP7601 series modems The software download page can be found here https software cisco com download navigator html mdfid 286288566 flowid 76082 2GGSM GPRS E...

Страница 24: ...ry mating connector plug is attached to the receptacle It is removed during installation and used to connect to the DC power source then reattached to provide power to the unit Refer to Figure 3 Power Connector Pin Outs on page 22 for the location and values of the power connector Figure 3 Power Connector Pin Outs Color Description Name Pin Number Red DC Power Positive Input DC In 1 Black DC Power...

Страница 25: ...e RS232 DTE pin out is different from the Cisco standard Console Auxiliary port The following figure shows the characteristics of the S0 and S1 ports The following table shows the S0 and S1 Details DCE DTE Abbreviation Description Pin Number DSR RI DCE Ready Ring Indicator 1 DCD Received Line Signal Detector 2 DTR DTE Ready 3 COM Signal Ground 4 RxD Received Data 5 TxD Transmitted Data 6 CTS Clear...

Страница 26: ...807 WALLMNT Cisco USB Type A Male to Mini B Male 6ft Console Cable CAB CONSOLE USB 37 1090 01 Depending on your particular model of the router there will be either a single hole or double hole grounding 53 100629 01 Contains Getting started with the Cisco 807 Integrated Services Router document associated hardware and the single hole grounding kit 53 100797 01 Contains Getting started with the Cis...

Страница 27: ...quipment Statement 1030 WARNING No user serviceable parts inside Do not open Statement 1073 WARNING Ultimate disposal of this product should be handled according to all national laws and regulations Statement 1040 WARNING Do not locate the antenna near overhead power lines or other electric light or power circuits or where it can come into contact with such circuits When installing the antenna tak...

Страница 28: ...e router hub servers and workstations or PCs Ensure that each device has a network interface card NIC for connecting to Ethernet ports Installing the Router This section describes how to install the Cisco 807 ISR This router can be installed on a table top or other flat horizontal surface mounted on a wall or DIN rail The recommended clearance when horizontally mounted is 1 inch on non connector s...

Страница 29: ... safety design of the product Do not operate the unit without the covers installed Statement 1077 WARNING Hot surface Statement 1079 To access the SIM card in the Cisco IR807 follow these steps 1 Power off the router and disconnect the power cable from the power source 2 Place the router on its bottom and ensure that any installed antennas are carefully oriented or disconnected to be out of the wa...

Страница 30: ...as There are two TNC connectors on the device The TNC connectors are used to connect to the 4G modem The SMA connector is for the GPS antenna Orient the antennas For optimum wireless performance the antennas should be perpendicular with respect to the floor If the router is being mounted on a desk orient the antennas straight up To attach the radio antennas to your wireless router follow these ste...

Страница 31: ...structions carefully before beginning installation Failure to use the correct hardware or to follow the correct procedures could result in a hazardous situation to people and damage to the system Statement 378 To mount the router on a wall or other flat surface follow these steps 1 Mark the location for the mounting brackets to attach to the wall The dimensions are described in Figure 4 Wall Mount...

Страница 32: ...ing To attach the DIN rail bracket to the Cisco IR807 follow these steps Mounting the DIN Rail Bracket on the Router 1 First attach the DIN rail bracket to the back of the router The DIN rail bracket mounts in two different ways depending on the orientation you wish to use See Figure 5 Attaching the DIN Rail Bracket for vertical mounting on page 30 for vertical orientation and Figure 6 Attaching t...

Страница 33: ...unds of torque to screw the bracket onto the router 2 Once the bracket is attached to the router it can be mounted onto the DIN Rail Attaching the Bracket onto the DIN Rail To attach the Cisco IR807 with the bracket to a DIN rail follow these steps Refer to Figure 7 Attaching the Bracket to the DIN Rail on page 32 for details Cisco IR807 Industrial Integrated Services Router Hardware Installation ...

Страница 34: ... of 1 4 in 5 to 7 mm For EN IEC 60950 1 compliant grounding use size 18 AWG 1 02mm or larger copper wire WARNING This equipment must be grounded Never defeat the ground conductor or operate the equipment in the absence of a suitably installed ground conductor Contact the appropriate electrical inspection authority or an electrician if you are uncertain that suitable grounding is available Statemen...

Страница 35: ... the router NOTE if your grounding lug is a single hole type attach it in the same manner as the dual hole using the first hole from the front panel 4 Use a ratcheting torque screwdriver to tighten the ground screw and ring terminal to the router side panel to 3 5 in lb 0 4 N m The torque should not exceed 3 5 in lb 0 4 N m 5 Attach the other end of the ground wire to a grounded bare metal surface...

Страница 36: ...Cisco IR807 Industrial Integrated Services Router Hardware Installation Guide 34 Installing the Router Installing the Router Ground Connection ...

Страница 37: ... router If you must supply your own cable see the Technical Specifications section on page 41 for cabling specifications If this appendix does not provide specifications for a particular cable we strongly recommend ordering the cable from Cisco Connecting a Terminal or PC to the Console Port The IR807 provides a mini type B USB console port Connect a terminal or PC to the Console port either to co...

Страница 38: ...product relies on the building s installation for short circuit overcurrent protection Ensure that the protective device is rated not greater than 10A Statement 1005 WARNING This product requires short circuit overcurrent protection to be provided as part of the building installation Install only in accordance with national and local wiring regulations Statement 1045 WARNING Connect the unit only ...

Страница 39: ...ct the DC power and alarm connections on the IR807 follow these steps Locate the power and alarm connector on the router front panel NOTE Your connector may not have the labels V RT A A In the labeled connector the pins are V Positive DC power connection RT Return DC power connection A Alarm Common A Alarm Input 1 Cisco IR807 Industrial Integrated Services Router Hardware Installation Guide 37 Con...

Страница 40: ...than the recommended amount of wire can leave exposed wire from the power connector after installation 4 Remove the two captive screws that attach the power and alarm connector to the router and remove the connector 5 1 Power connector captive screws On the power and alarm connector insert the exposed part of the positive wire into the connection labeled V and the exposed part of the return wire i...

Страница 41: ... return wire to the return terminal on the DC power source Connect the other end of the Alarm wires to your alarm source 8 Verifying Connections To verify that all devices are properly connected to the router first turn on all the connected devices then check the LEDs To verify router operation refer to the Front Panel Icons and LEDs page 10 Cisco IR807 Industrial Integrated Services Router Hardwa...

Страница 42: ...Cisco IR807 Industrial Integrated Services Router Hardware Installation Guide 40 Connecting the Router Verifying Connections ...

Страница 43: ...able 6 Physical Characteristics Design Specification Description height x width x depth x are 1 85 x 5 07 x 4 50 4 69 x 12 85 x 11 43 cm Dimensions H x W x D Table 7 Environmental Operating Ranges Design Specification Description 40 to 140 F 40 to 60 C in a sealed NEMA cabinet with no airflow 40 to 158 F 40 to 70 C in a vented cabinet with 40 lfm of air 40 to 167 F 40 to 75 C in a forced air enclo...

Страница 44: ...fications EN55022 CISPR22 CFR 47 Part 15 ICES003 VCCI V 3 AS NZS CISPR22 CNS13438 EN300 386 EN61000 3 2 EN61000 3 3 and EN55032 CISPR32 EMC Emissions EN55024 CISPR24 EN61000 4 2 EN61000 4 3 EN61000 4 4 EN61000 4 5 EN61000 4 6 EN61000 4 11 EN55035 CISPR35 and EN300 386 EMC Immunity EN 301 908 1 EN 301 908 2 EN 301 511 and EN 301 908 13 Cellular Radio IP30 compliant when vertical and cables downward...

Страница 45: ...SMI IC Country marks Table 13 Hazardous Locations Design Specification Description ANSI ISA 12 12 01 Gas groups A D CSA 22 2 No 213 Gas groups A D UL CSA 60079 0 15 Class I Zone 2 Gas groups IIC IEC 60079 0 15 IECEx test report EN 60079 0 15 ATEX certification Class I Zone 2 Gas groups IIC Hazardous Locations Cisco IR807 Industrial Integrated Services Router Hardware Installation Guide 43 Technica...

Страница 46: ...Cisco IR807 Industrial Integrated Services Router Hardware Installation Guide 44 Technical Specifications Router Specifications ...

Отзывы: