A-23
Cisco 12404 Internet Router Installation and Configuration Guide
OL-11636-01
Appendix A Technical Specifications
Product Architecture
Connect each AC PEM to a separate AC power source.
A power factor corrector (PFC) allows the PEM to accept AC power source
voltage from an AC power source nominally operating between 100 to 120 VAC,
15-Amp service in North America; and a range of 185 to 264 VAC, 10-Amp
service, in an international environment.
Figure A-6
AC PEM
A 14 ft. (4.3 m) AC power cord is supplied to connect the AC PEM to the power
source.
Note
Install an uninterruptable power source (UPS) as a safeguard against power loss.
DC Power Entry Module
The DC PEM and DC PDU is a 2-part unit, which measures 6.60 inches
(16.76 cm) deep by 14.30 inches (36.32 cm) wide by 3.50 inches (8.89 cm) high
and weighs 14.0 lbs (6.35 kg). Refer to
.
1
AC PEM handle
4
Power cord receptacle
2
On/Off switch
5
LEDs
3
Bail Latch
6
Captive screws
INPUT
OK
OUTPUT
FAIL
INPUT
100-240V
12A
50/80HZ
OUTPUT
OK
66289
4
5
6
1
2
3
todd.book Page 23 Tuesday, November 27, 2007 6:02 PM