Switch Installation

 

Connecting to Power

Warning: 

Installation of the equipment must comply with local and national electrical codes. Statement 1074

2.

Use a ratcheting torque flathead screwdriver to tighten the captive screws on the sides of the power connectors.

When you are testing the switch, one power source is sufficient. If you are installing the switch and are using a second 
power source, repeat this procedure for the second power connector (DC-B), which installs just below the primary power 
connector (DC-A).

When you are installing the switch, secure the wires coming from the power connector so that they cannot be disturbed 
by casual contact. For example, use tie wraps to secure the wires to the rack.

Applying Power to the Power Converter

Move the circuit breaker for the AC outlet or the DC control circuit to the 

on

 position.

The LED on the power converter front panel is green when the unit is operating normally. The LED is off when the unit is 
not powered or is not operating normally. After the power is connected, the switch automatically begins the power-on 
self- test (POST), a series of tests that verifies that the switch functions properly. 

Running Boot Fast

When the switch powers on, it automatically initiates a boot fast sequence. To test the switch, follow the steps in these 
sections:

Powering On the Switch, page 28

Verifying Boot Fast, page 28

Disconnecting Power, page 28

Powering On the Switch

To apply power to a switch that is directly connected to a DC power source, locate the circuit breaker on the panel board 
that services the DC circuit, and switch the circuit breaker to the ON position.

Verifying Boot Fast

When you power on the switch, it automatically begins a boot fast sequence. The System LED blinks green as the Cisco 
IOS software image loads. If the boot fast sequence fails, the System LED turns red.

Note: 

Boot fast failures are usually fatal. Call Cisco TAC immediately if your switch does not complete boot fast 

successfully.

Note: 

You can disable the boot fast and run POST by using the Cisco IOS CLI. See the 

Cisco IE 4000 Switch Software 

Configuration Guide

 for more information.

Disconnecting Power

To disconnect power after successfully running boot fast, follow these steps:

1.

Turn off power to the switch.

2.

Disconnect the cables.

Содержание IE 4000

Страница 1: ...Cisco Systems Inc www cisco com Cisco IE 4000 Switch Hardware Installation Guide First Published September 2015 Last Updated December 2015 ...

Страница 2: ...se the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Modifications to this product not authorized by Cisco could void the FCC approval and negate your authority to operate the product The Cisco implementation of TCP header compre...

Страница 3: ... helpful suggestions or references to materials not contained in this manual Caution Means reader be careful In this situation you might do something that could result in equipment damage or loss of data Warning This warning symbol means danger You are in a situation that could cause bodily injury Before you work on any equipment be aware of the hazards involved with electrical circuitry and be fa...

Страница 4: ...Compatibility Matrix not orderable but available on Cisco com Cisco Small Form Factor Pluggable Modules Compatibility Matrix not orderable but available on Cisco com Obtaining Documentation Obtaining Support and Security Guidelines For information on obtaining documentation obtaining support providing documentation feedback security guidelines and also recommended aliases and general Cisco documen...

Страница 5: ...IE 4000 can easily be installed in your network Through a user friendly web device manager the Cisco IE 4000 provides easy out of the box configuration and simplified operational manageability to deliver advanced security data video and voice services over industrial networks Switch Models Model Description IE 4000 4TC4G E 4 FE Combo DL ports 4 GE combo UL ports w FPGA IE 4000 8T4G E 8 FE Copper D...

Страница 6: ...lf duplex mode You can also set these ports for speed and duplex autonegotiation in compliance with IEEE 802 3AB The default setting is autonegotiate When set for autonegotiation the port senses the speed and duplex settings of the attached device and advertises its own capabilities If the connected device also supports autonegotiation the switch port negotiates the best 1 SFP module slots uplink ...

Страница 7: ...ide full duplex 100 or 1000 Mb s connectivity over multi mode MM fiber cables or single mode SM fiber cables These ports use a SFP fiber optic transceiver module that accepts a dual LC connector Check the SFP specifications for the cable type and length Dual Purpose Fast Ethernet Downlink Ports You can configure the dual purpose Fast Ethernet Downlink ports on the switch as either 10 100BASE T por...

Страница 8: ... B connectors but they are not compatible Use only the 5 pin mini Type B See Figure 2 on page 4 Figure 2 USB Mini Type B Port The configurable inactivity timeout reactivates the RJ 45 console port if the USB mini console port is activated but no input activity occurs for a specified time period When the USB mini console port deactivates due to a timeout you can restore its operation by disconnecti...

Страница 9: ...cuit is a relay with a normally open and a normally closed contact The switch is configured to detect faults that are used to energize the relay coil and change the state on both of the relay contacts normally open contacts close and normally closed contacts open The alarm output relay can be used to control an external alarm device such as a bell or a light See the switch software configuration g...

Страница 10: ...M RGD 220 550 m MMF GLC LH SM GLC LH SMD 550m 10km MMF SMF SFP GE L 550m 10km MMF SMF X GLC LX SM RGD 550m 10km MMF SMF GLC T 100 m CAT5 GLC BX U 10km SMF X GLC BX D 10km SMF X GLC ZX SM GLC ZX SMD 70km SMF X GLC EX SMD 40km SMF X SFP GE Z 70km SMF X GLC ZX SM RGD 70km SMF X 100 Mb SFP for FE DL Distance Fiber DOM GLC FE 100FX 2km MMF GLC FE 100FX RGD 2km MMF GLC FE 100LX 10km SMF GLC FE 100LX RGD...

Страница 11: ...cate the chosen display mode Each time you press the switch the mode indicator will move from Speed Duplex PoE Synce and HSR PRP respectively 1 Dual Media port LEDs 9 USB mini Type B console port LED 2 SFP module slot LEDs 10 Display Mode Switch 3 10 100 1000 BASE T downlink port LEDs 11 HSR PRP 4 Alarm LEDs 12 SYNCE LED 5 Power connector DC A LED 13 POE port status LED 6 Power connector DC B LED ...

Страница 12: ... operating normally Blinking green Switch is in initial setup in recovery or initial setup is incomplete Solid red Switch failed to start initial setup or recovery because there is no available switch port to which to connect the management station Disconnect a device from a switch port and then press the Express Setup button Color System Status Off System is not powered on Blinking green Boot fas...

Страница 13: ... information about the power LED colors during the boot fast sequence see Verifying Switch Operation page 39 Port Status LEDs Each port and SFP uplink slot has a status LED as shown in Figure 4 on page 7 and described below Color System Status Off Alarm IN1 or IN2 not configured Green Alarm IN1 or IN2 configured no alarm detected Blinking red Major alarm detected Red Minor alarm detected Color Sys...

Страница 14: ...oving the flash memory card see Installing or Removing the Flash Memory Card Optional page 16 Note The replacement SD card part number is SD IE 1GB Rear Panel The rear panel of the switch has a latch for installation on a DIN rail See Figure 5 on page 11 The latch is spring loaded to move down to position the switch over a DIN rail and return to the original position to secure the switch to a DIN ...

Страница 15: ... available at no cost and can be downloaded from this URL http www cisco com en US products ps5931 tsd_products_support_series_home html For information on starting the Cisco Network Assistant application see the Getting Started with Cisco Network Assistant guide on Cisco com Device Manager You can use Device Manager which is in the switch memory to manage individual and standalone switches This w...

Страница 16: ...ment Information Base MIB extensions and four Remote Monitoring RMON groups See the switch software configuration guide on Cisco com and the documentation that came with your SNMP application for more information Common Industrial Protocol The Common Industrial Protocol CIP management objects are supported The Cisco IE 4000 can be managed by CIP based management tools allowing the user to manage a...

Страница 17: ...9 Preparing for Installation This section provides information about these topics Warnings page 13 Installation Guidelines page 15 Installation Guidelines page 15 Verifying Package Contents page 16 Warnings These warnings are translated into several languages in the Regulatory Compliance and Safety Information for this switch Warning Before working on equipment that is connected to power lines rem...

Страница 18: ...ions in a hazardous location the DC power source could be located away from the vicinity of the switch Before performing any of the following procedures locate the DC circuit to ensure that the power is removed and cannot be turned on accidentally or verify that the area is nonhazardous before proceeding Statement 1059 Warning This equipment is supplied as open type equipment It must be mounted wi...

Страница 19: ...l be present and appropriately designed to prevent personal injury resulting from accessibility to live parts The enclosure must have suitable flame retardant properties to prevent or minimize the spread of flame complying with a flame spread rating of 5VA V2 V1 V0 or equivalent if nonmetallic The interior of the enclosure must be accessible only by the use of a tool Subsequent sections of this pu...

Страница 20: ...oom temperature outside the enclosure Ensure temperatures inside the enclosure conform to device specifications detailed in Table 3 on page 59 Cabling is away from sources of electrical noise such as radios power lines and fluorescent lighting fixtures Verifying Package Contents If any item is missing or damaged contact your Cisco representative or reseller for support Installing or Removing the F...

Страница 21: ...rd is installed close the guard door and fasten the captive screw using a Phillips screwdriver to keep the door in place Connecting to a Console Port Optional You can also enter CLI commands through the console port For more information about this process see Accessing the CLI Through the Console Port page 45 Warning If you connect or disconnect the console cable with power applied to the switch o...

Страница 22: ...g terminals such as Hollingsworth part number R3456B or equivalent Crimping tool such as Thomas Bett part number WT4000 ERG 2001 or equivalent 10 gauge copper ground wire For DC power connections use UL and CSA rated style 1007 or 1569 twisted pair copper appliance wiring material AWM wire Wire stripping tools for stripping 10 and 18 gauge wires A number 2 Phillips screwdriver A flat blade screwdr...

Страница 23: ...grounded to comply with emission and immunity requirements Ensure that the switch functional ground lug is connected to earth ground during normal use Statement 1064 Caution To make sure that the equipment is reliably connected to earth ground follow the grounding procedure instructions and use a UL listed ring terminal lug suitable for number 10 to 12 AWG wire such as Hollingsworth part number R3...

Страница 24: ...rmine the wire length to be stripped 3 Insert the ground wire into the ring terminal lug and using a crimping tool crimp the terminal to the wire See Figure 7 on page 20 If two ring terminals are being used repeat this action for a second ring terminal Figure 7 Crimping the Ring Terminal 4 Slide the ground screw through the terminal 5 Insert the ground screw into the functional ground screw openin...

Страница 25: ...on page 21 Connecting the AC Power Source to the Power Converter page 22 Preparing the AC Power Connection To connect the power converter to an AC power source you need an AC power cord Power cord connector types and standards vary by country Power cord wiring color codes also vary by country You must to have a qualified electrician select prepare and install the appropriate power cord to the powe...

Страница 26: ... used Refer to Table 2 on page 19 for the appropriate DC input ratings Note Use copper conductors only rated at a minimum temperature of 167 F 75 C 1 Measure a single length of stranded copper wire long enough to connect the power converter to the earth ground The wire color might differ depending on the country that you are using it in For connections from the power converter to earth ground use ...

Страница 27: ...at the protective device is rated not greater than 3A Statement 1005 Warning Installation of the equipment must comply with local and national electrical codes Statement 1074 Warning Before performing any of the following procedures ensure that power is removed from the DC circuit Statement 1003 Warning Only trained and qualified personnel should be allowed to install replace or service this equip...

Страница 28: ...nector insert the exposed part of the positive wire into the connection labeled and the exposed part of the return wire into the connection labeled See Figure 11 on page 25 Make sure that you cannot see any wire lead Only wire with insulation should extend from the connector Warning An exposed wire lead from a DC input power source can conduct harmful levels of electricity Be sure that no exposed ...

Страница 29: ...head screwdriver to torque the power connector captive screws above the installed wire leads to 5in lb 0 565 Nm See Figure 12 on page 26 Caution Do not over torque the power connector s captive screws The torque should not exceed 5in lb 0 565 Nm 1 Power source positive connection 2 Power source return connection 332021 1 2 ...

Страница 30: ...ire to the return terminal on the DC power source When you are testing the switch one power connection is sufficient If you are installing the switch and are using a second power source repeat Step 4 through Step 8 using the second power connector Figure 13 on page 27 shows the completed DC input wiring on a power connector for a primary power source and an optional secondary power source 1 Power ...

Страница 31: ...urrent protection Ensure that the protective device is rated not greater than 7 5A Statement 1005 Warning When you connect or disconnect the power and or alarm connector with power applied an electrical arc can occur This could cause an explosion in hazardous area installations Be sure that all power is removed from the switch and any other circuits Be sure that power cannot be accidentally turned...

Страница 32: ... switch automatically begins the power on self test POST a series of tests that verifies that the switch functions properly Running Boot Fast When the switch powers on it automatically initiates a boot fast sequence To test the switch follow the steps in these sections Powering On the Switch page 28 Verifying Boot Fast page 28 Disconnecting Power page 28 Powering On the Switch To apply power to a ...

Страница 33: ...odes and in accordance with the authority having jurisdiction over Class I Division 2 installations Statement 1066 Caution To prevent the switch from overheating ensure these minimum clearances Top and bottom 2 0 in 50 8 mm Exposed side not connected to the module 2 0 in 50 8 mm Front 2 0 in 50 8 mm Installing the Switch on a DIN Rail The switch ships with a spring loaded latch on the rear panel f...

Страница 34: ...ram page 45 Note For instructions on how to remove the switch from a DIN rail see Removing the Switch from a DIN Rail page 30 Removing the Switch from a DIN Rail To remove the switch from a DIN rail follow these steps 1 Ensure that power is removed from the switch and disconnect all cables and connectors from the front panel of the switch 2 Insert a tool such as a flathead screwdriver in the slot ...

Страница 35: ...ng the Protective Ground and DC Power for Alarm Circuits For instructions on grounding the switch and connecting the DC power see the Grounding the Switch page 19 Wiring the External Alarms The switch has two alarm input and one alarm output relay circuits for external alarms The alarm input circuits are designed to sense if the alarm input is open or closed relative to the alarm input reference p...

Страница 36: ...an electrical arc can occur This could cause an explosion in hazardous location installations Be sure that power is removed or that the area is nonhazardous before proceeding Statement 1081 Caution The input voltage source of the alarm output relay circuit must be an isolated source and limited to less than or equal to 24 VDC 1 0 A or 48 VDC 0 5 A Note Wire connections to the power and alarm conne...

Страница 37: ...om both ends of each wire to 0 25 inch 6 3 mm 0 02 inch 0 5 mm Do not strip more than 0 27 inch 6 8 mm of insulation from the wires Stripping more than the recommended amount of wire can leave exposed wire from the alarm connector after installation 4 Insert the exposed wires for the external alarm device into the connections based on an alarm input or output circuit setup For example to wire an a...

Страница 38: ...Securing the Alarm Connector Captive Screws 6 Repeat Step 2 through Step 5 to insert the input and output wires of one additional external alarm device into the alarm connector Figure 19 on page 35 shows the completed wiring for two external alarm devices The first alarm device circuit is wired as an alarm input circuit the IN1 and REF connections complete the circuit The second alarm device circu...

Страница 39: ...Be sure that power cannot be accidentally turned on or verify that the area is nonhazardous before proceeding Statement 1058 To attach the alarm connector to the front panel of the switch follow these steps 1 Insert the alarm connector into the receptacle on the switch front panel 2 Use a ratcheting torque flathead screwdriver to tighten the captive screws on the sides of the alarm connector Conne...

Страница 40: ...ble to an RJ 45 connector on the front panel When connecting to 1000BASE T compatible devices use a twisted four pair Category 5 or higher cable The auto MDIX feature is enabled by default For configuration information for this feature see the Cisco IE 4000 Switch Software Configuration Guide 2 Connect the other end of the cable to an RJ 45 connector on the other device The port LED turns on when ...

Страница 41: ...lasp Latch To insert an SFP module into the SFP module slot 1 Attach an ESD preventive wrist strap to your wrist and to a grounded bare metal surface 2 Find the send TX and receive RX markings that identify the correct side of the SFP module On some SFP modules the send and receive TX and RX markings might be replaced by arrows that show the direction of the connection either send or receive TX or...

Страница 42: ...tatement 1070 Caution Do not remove the rubber plugs from the SFP module port or the rubber caps from the fiber optic cable until you are ready to connect the cable The plugs and caps protect the SFP module ports and cables from contamination and ambient light Before connecting to the SFP module be sure that you understand the port and cabling guidelines in the Preparing for Installation page 13 T...

Страница 43: ...ion command For more information see the Cisco IE 4000 Switch Command Reference Verifying Switch Operation Before installing the switch in its final location power on the switch and verify that the switch powers up in boot fast style The boot fast sequence allows the switch to boot up in less than 60 seconds Where to Go Next If the default configuration is satisfactory the switch does not need fur...

Страница 44: ...40 Switch Installation Where to Go Next ...

Страница 45: ...ers or proxy settings on your browser and any wireless client running on your computer Express Setup Procedure To run Express Setup 1 Make sure that nothing is connected to the switch 2 Ensure theIE4000 is in default factory mode Skip to next step if freshly out of the box a If not freshly out of the package use a paper clip to reset the switch for 10 seconds until the SYS LED light turns red then...

Страница 46: ... LED starts flashing green 8 Connect computer to port Gig1 1 LED continues to blink 9 After computer has IP Address 169 254 0 2 point browser to http 169 254 0 1 10 Leave the username blank and enter the default password cisco Note The switch ignores text in the username field The Express Setup window appears Troubleshooting If the Express Setup window does not appear make sure that any pop up blo...

Страница 47: ...LAN settings click Help on the tool bar 13 Optional Settings You can enter the optional information now or enter it later by using Device Manager For more information about the Express Setup fields see the on line help for the Express Setup window Click Submit to save your changes and to complete the initial setup For more information about the optional settings click Help on the tool bar 14 After...

Страница 48: ...on the computer Make sure that the switch IP address in the browser is correct If the switch IP address in the browser is correct the switch port LED is green and the computer has network connectivity continue troubleshooting by reconnecting the computer to the switch Configure a static IP address on the computer that is in the same subnet as the switch IP address When the LED on the switch port c...

Страница 49: ...tch Installation page 13 Accessing the CLI Through the Console Port You can enter Cisco IOS commands and parameters through the CLI Use one of these options to access the CLI RJ 45 Console Port page 46 USB Mini Type B Console Port page 47 Removing the USB Mini Type B Console Port Cover To remove the cover from the USB mini type B console port 1 Use a Phillips screwdriver to loosen the captive scre...

Страница 50: ...he RJ 45 to DB 9 adapter cable to the 9 pin serial port on the PC Connect the other end of the cable to the switch console port 2 Start the terminal emulation program on the PC or the terminal The program frequently a PC application such as HyperTerminal or ProcommPlus makes communication between the switch and your PC or terminal possible 1 USB Mini Type B Console Port Cover ...

Страница 51: ...splays the bootloader sequence Press Enter to display the setup prompt Follow the steps in the Completing the Setup Program page 50 USB Mini Type B Console Port 1 If you are connecting the switch USB mini console port to a Windows based PC for the first time install a USB driver See Installing the Cisco Microsoft Windows XP 2000 Vista 7 8 and 10 USB Device Driver page 48 for more information 2 Con...

Страница 52: ... in the Completing the Setup Program page 50 Installing the Cisco Microsoft Windows XP 2000 Vista 7 8 and 10 USB Device Driver A USB device driver must be installed the first time a Microsoft Windows based PC is connected to the USB console port on the switch Use this procedure to install the USB driver on Windows XP Windows 2000 Windows Vista Windows 7 Windows 8 and Windows 10 1 Obtain the file C...

Страница 53: ... Next 4 When the Program Maintenance window appears select the Remove radio button 5 Click Next 6 When the Remove the Program window appears click Remove If a User Account Control warning appears click Allow I trust this program to proceed 7 When the InstallShield Wizard Completed window appears click Finish Entering the Initial Configuration Information To set up the switch you need to complete t...

Страница 54: ...paces but ignores leading spaces The secret password is encrypted and the enable password is in plain text Enter enable secret secret_password 4 Enter an enable password and press Return Enter enable password enable_password 5 Enter a virtual terminal Telnet password and press Return The password can be from 1 to 25 alphanumeric characters is case sensitive allows spaces but ignores leading spaces...

Страница 55: ... 1 ZQRe DPulYXyQLm77v a4Bmu6Y enable password cisco line vty 0 15 password cisco no snmp server interface Vlan1 no shutdown ip address 10 4 120 106 255 0 0 0 interface FastEthernet1 1 interface FastEthernet1 2 interface FastEthernet1 3 output abbreviated interface GigabitEthernet1 1 interface GigabitEthernet1 2 end 10 These choices appear 0 Go to the IOS command prompt without saving this config 1...

Страница 56: ...mmands at the Switch prompt through the console port by using a terminal emulation program or through the network by using Telnet For configuration information see the switch Cisco IE 4000 Switch Software Configuration Guide To use the Cisco Network Assistant see the Getting Started with Cisco Network Assistant guide on Cisco com ...

Страница 57: ...can disable the boot fast and run POST by using the Cisco IOS CLI see the Cisco IE 4000 Switch Software Configuration Guide for more information Switch LEDs Look at the port LEDs information when troubleshooting the switch See LEDs page 6 for a description of the LED colors and their meanings Switch Connections Bad or Damaged Cable Always examine the cable for marginal damage or failure A cable mi...

Страница 58: ...e connected to the correct ports Verify that both devices have power Verify that you are using the correct cable type See Cables and Adapters page 65 for information Look for loose connections Sometimes a cable appears to be seated but is not Disconnect the cable and then reconnect it 10 100 1000 Port Connections If a port appears to malfunction Verify the status of all ports by checking the LEDs ...

Страница 59: ...configuration guide on Cisco com Switch Performance Speed Duplex and Autonegotiation Port statistics that show a large amount of alignment errors frame check sequence FCS or late collisions errors might mean a speed or duplex mismatch A common issue occurs when duplex and speed settings are mismatched between two switches between a switch and a router or between the switch and a workstation or ser...

Страница 60: ...em LED turns green after the switch completes rebooting 2 Press the Express Setup button again for 3 seconds A switch 10 100 Ethernet port blinks green The switch now behaves like an unconfigured switch You can configure the switch by using the CLI setup procedure described in Configuring the Switch with the CLI Based Setup Program page 45 How to Recover Passwords Password recovery is a feature th...

Страница 61: ...57 Troubleshooting Finding the Switch Serial Number Figure 23 Serial Number Location for the Cisco IE 4000 Switches 1 Compliance Label ...

Страница 62: ...58 Troubleshooting Finding the Switch Serial Number ...

Страница 63: ...er 158 F 70 C However the Cisco IE 4000 switch can function in the substation and traffic signal installations under the environmental conditions shown in Table 3 on page 59 Table 3 Operating Temperature for the Cisco IE 4000 Switches Industrial Automation and Hazardous Locations Substation Traffic Signal Enclosure types Sealed enclosures For example NEMA4 NEMA4X NEMA12 NEMA13 IP54 and IP66 Vented...

Страница 64: ...cess This is due to the internal heaters that heat up the devices to safe operating temperature Operating humidity 5 to 95 noncondensing Operating shock 30 g at 11 ms and 200 g at 2 11 ms Operating altitude Up to 13 000 ft 3962 m Storage altitude Up to 40 000 ft 12 192 m Power Requirements DC input voltage Maximum operating range 9 6 to 60 VDC Nominal 12 24 or 48 VDC Note The DC input power supply...

Страница 65: ...ions 6 12 x 6 12 x 5 09 in 155 4 x 155 4 x 129 2 mm PWR IE170W PC AC 5 93 x 3 72 x 5 60 in 150 6 x 94 5 x 142 2 PWR IE170W PC DC 5 93 x 4 47 x 5 75 in 150 6 x 113 5 x 145 8 PWR IE50W AC 5 8 x 2 0 x 4 4 in 147 x 51 x 112 mm PWR IE50W AC IEC 5 8 x 2 0 x 4 4 in 147 x 51 x 112 mm PWR IE65W PC AC 5 9 x 2 6 x 4 6 in 150 x 66 x 117 mm PWR IE65W PC DC 5 9 x 2 6 x 4 6 in 150 x 66 x 117 mm 1 Operating tempe...

Страница 66: ...itches are below 4 To calculate the depth excluding the rail subtract 0 22 in 0 6 cm Table 5 Cisco IE 4000 Alarm Ratings Alarm Ratings Specification Alarm input electrical specification No power required open or closed state detected Alarm output electrical specification 1 0 A 24 VDC or 0 5 A 48 VDC ...

Страница 67: ...es use RJ 45 connectors Figure 2410 100 Port Pinouts page 63 shows the pinouts Figure 24 10 100 Port Pinouts Note For the three models of IE 4000 switch that support PoE connector pins 4 and 5 supply 48 VDC and pins 7 and 8 are the DC voltage return lines SFP Module Connectors Figure 25Fiber Optic SFP Module LC Connector page 64 shows a MT RJ style connector that is used with the SFP Module slots ...

Страница 68: ...ort Pinouts Console Port The switch has two console ports a USB 5 pin mini Type B port on the front panel see Figure 27 on page 64 and an RJ 45 console port on the rear panel Figure 27 USB Mini Type B Port The USB console port uses a USB Type A to 5 pin mini Type B cable shown in Figure 28USB Type A to USB 5 Pin Mini Type B Cable page 65 The USB Type A to USB mini Type B cable is not supplied You ...

Страница 69: ...the switch panel and are displayed below Cables and Adapters SFP Module Cables page 65 Cable Pinouts page 68 Console Port Adapter Pinouts page 70 SFP Module Cables Each port must match the wave length specifications on each end of the cable and for reliable communications the cable must not exceed the allowable length Notes The maximum operating temperature of the switch varies depending on the ty...

Страница 70: ...ne optical attenuator between the fiber optic cable plant and the receiving port on the 1000BASE ZX SFP module Table 6 Commercial SFPs Fiber Optic SFP Module Port Cabling Specifications Type of SFP Module Model Wavelength nanometers Fiber Type Core Size Claddin g Size micron Modal Bandwidth MHz km Cable Distance 1000BASE BX10 D GLC BX D 1490 TX 1310 RX SMF G 652 6 2 miles 10 km 1000BASE BX10 U GLC...

Страница 71: ...E LX LH GLC LX SM R GD 1310 MMF SMF 62 5 50 0 50 0 G 652 500 400 500 1804 feet 550 m 1804 feet 550 m 1804 feet 550 m 6 2 miles 10 km 1000BASE SX GLC SX MM R GD 850 MMF 62 5 125 62 5 125 50 125 50 125 160 200 400 500 722 feet 220 m 902 feet 275 m 1640 feet 500 m 1804 feet 550 m 1000BASE ZX GLC ZX SM R GD 1550 SMF G 652 43 4 to 62 miles 70 to 100 km 100BASE FX GLC FE 100FX RGD 1310 MMF 62 5 125 62 5...

Страница 72: ...00BASE LX LH SFP GE L 1300 MMFor SMF 62 2 50 50 9 10 500 400 500 1804 feet 550 m 1804 feet 550 m 1804 feet 550 m 6 2 miles 10 km 100BASE SX SFP GE S 850 MMF 62 5 62 5 50 0 50 0 160 200 400 500 722 feet 220 m 902 feet 275 m 1640 feet 500 m 1804 feet 550 m 100BASE ZX GLC SX SMD 850 MMF 62 5 62 5 50 0 50 0 50 0 160 200 400 500 2000 722 feet 220 m 902 feet 275 m 1640 feet 500 m 1804 feet 550 m 3281 fe...

Страница 73: ... 1 on the left end should be the same color as the wire connected to pin 3 on the right end The wire connected to pin 2 on the left end should be the same color as the wire connected to pin 6 on the right end Figure 33 Identifying a Crossover Cable 1 TP0 2 TP0 3 TP1 6 TP1 1 TP0 2 TP0 3 TP1 6 TP1 Switch Router or PC 4 TP2 5 TP2 7 TP3 8 TP3 4 TP2 5 TP2 7 TP3 8 TP3 65271 1 TP0 2 TP0 3 TP1 6 TP1 1 TP0...

Страница 74: ...the switch console port to a terminal You can order an adapter part number ACS DSBUASYN Note The RJ 45 to DB 25 female DTE adapter is not supplied with the switch You can order this adapter from Cisco part number ACS DSBUASYN Switch Console Port DTE RJ 45 to DB 9 Terminal Adapter Console Device Signal DB 9 Pin Signal RTS 8 CTS DTR 6 DSR TxD 2 RxD GND 5 GND RxD 3 TxD DSR 4 DTR CTS 7 RTS Switch Cons...

Страница 75: ...prevent personal injury resulting from accessibility to live parts The interior of the enclosure must be accessible only by the use of a tool The enclosure must meet IP 54 or NEMA type 4 minimum enclosure rating standards Statement 1063 Warning When used in a Class I Division 2 hazardous location this equipment must be mounted in a suitable enclosure with proper wiring method for all power input a...

Страница 76: ...trol Earthing and bonding shall meet the requirements of ETS 300 253 or CCITT K27 AC power distribution shall be one of the following types where applicable TN S and TN C as defined in IEC 364 3 In addition if equipment is operated in a domestic environment interference could occur English Products marked Class I Div 2 GP A B C D are suitable for use in Class I Division 2 Groups A B C D Hazardous ...

Страница 77: ...VDC Physical Dimensions Weight 1 4 lb 0 63 kg Dimensions W x D x H 2 x 4 62 x 5 81 in 50 8 x 117 5 x 147 6 mm Note Width includes the cosmetic end caps Height does not include the panel mount brackets Depth is the distance from the rail The following standards were used for the hazardous locations approvals and certifications Les normes suivantes ont été appliquées pour les approbations et les cer...

Страница 78: ...74 Hazardous Location Installation Information Hazardous Locations Standards ...

Отзывы: