Cisco Edge 300 Series Switch Installation Guide
OL-24909-02
Installing the Switch
Before You Begin
Before installing the switch, verify that these guidelines are met:
•
Front clearance so that the LEDs can be seen.
•
AC power cord reaches from the AC power outlet to the rear-panel connector.
•
Cabling is away from sources of electrical noise, such as radios, power lines, and fluorescent
lighting. Make sure that the cabling is safely away from other devices that might damage the cables.
•
Airflow around the switch is unrestricted.
•
Temperature around the unit does not exceed 104°F (40°C).
•
Humidity around the switch does not exceed 85 percent.
•
Altitude at the installation site is below 10,000 feet.
•
For Ethernet ports, cables from the switch to connected devices are not longer than 328 feet
(100 meters).
Warning Statements
Statement 1071
Statement 332
Warning
In order to comply with FCC radio frequency (RF) exposure limits, antennas should be located at a
minimum of 7.9 inches (20 cm) or more from the body of all persons.
Statement 332
Statement 1005
Warning
This product relies on the building’s installation for short-circuit (overcurrent) protection. Ensure that
the protective device is rated not greater than:
20A
Statement 1005
Warning
IMPORTANT SAFETY INSTRUCTIONS
This warning symbol means danger. You are in a situation that could cause bodily injury. Before you
work on any equipment, be aware of the hazards involved with electrical circuitry and be familiar
with standard practices for preventing accidents. Use the statement number provided at the end of
each warning to locate its translation in the translated safety warnings that accompanied this
device.
Statement 1071
SAVE THESE INSTRUCTIONS