background image

 

12

Installing Hard Disk Drives in the Cisco Wide Area Application Engine 611

78-17404-01

  Obtaining Technical Assistance

In an emergency, you can also reach PSIRT by telephone:

1 877 228-7302

1 408 525-6532

Tip

We encourage you to use Pretty Good Privacy (PGP) or a compatible product to encrypt any sensitive 
information that you send to Cisco. PSIRT can work from encrypted information that is compatible with 
PGP versions 2.

x

 through 8.

x

Never use a revoked or an expired encryption key. The correct public key to use in your correspondence 
with PSIRT is the one linked in the Contact Summary section of the Security Vulnerability Policy page 
at this URL:

http://www.cisco.com/en/US/products/products_security_vulnerability_policy.html

The link on this page has the current PGP key ID in use.

Obtaining Technical Assistance

Cisco Technical Support provides 24-hour-a-day award-winning technical assistance. The Cisco 
Technical Support & Documentation website on Cisco.com features extensive online support resources. 
In addition, if you have a valid Cisco service contract, Cisco Technical Assistance Center (TAC) 
engineers provide telephone support. If you do not have a valid Cisco service contract, contact your 
reseller.

Cisco Technical Support & Documentation Website

The Cisco Technical Support & Documentation website provides online documents and tools for 
troubleshooting and resolving technical issues with Cisco products and technologies. The website is 
available 24 hours a day, at this URL:

http://www.cisco.com/techsupport

Access to all tools on the Cisco Technical Support & Documentation website requires a Cisco.com user 
ID and password. If you have a valid service contract but do not have a user ID or password, you can 
register at this URL:

http://tools.cisco.com/RPF/register/register.do

Note

Use the Cisco Product Identification (CPI) tool to locate your product serial number before submitting 
a web or phone request for service. You can access the CPI tool from the Cisco Technical Support & 
Documentation website by clicking the 

Tools & Resources

 link under Documentation & Tools.

 

Choose 

Cisco Product Identification Tool

 from the Alphabetical Index drop-down list, or click the 

Cisco 

Product Identification Tool

 link under Alerts & RMAs. The CPI tool offers three search options: by 

product ID or model name; by tree view; or for certain products, by copying and pasting 

show

 command 

output. Search results show an illustration of your product with the serial number label location 
highlighted. Locate the serial number label on your product and record the information before placing a 
service call.

Содержание DISK-611SC-144GB=

Страница 1: ...his publication contains the following sections Safety Overview page 1 Introduction page 3 Removing the Bezel and Cover page 4 Assigning SCSI IDs page 6 Removing and Replacing a SCSI Hard Disk Drive page 7 Replacing the Cover and Bezel and Completing the Installation page 10 Obtaining Documentation page 11 Cisco Product Security Overview page 11 Obtaining Technical Assistance page 12 Note For tran...

Страница 2: ...ines Before installing your device in a rack review the following guidelines Two or more people are required to install the device in a rack Ensure that the room air temperature is below 95 F 35 C Do not block any air vents usually 6 inches 15 cm of space provides proper airflow Plan the device installation starting from the bottom of the rack Install the heaviest device in the bottom of the rack ...

Страница 3: ...lank faceplates and cover panels serve three important functions they prevent exposure to hazardous voltages and currents inside the chassis they contain electromagnetic interference EMI that might disrupt other equipment and they direct the flow of cooling air through the chassis Do not operate the system unless all cards faceplates front covers and rear covers are in place Statement 1029 Warning...

Страница 4: ... the ground connection must always be made first and disconnected last Statement 1046 To remove the bezel and cover follow these steps Step 1 Review the information in the Protecting Against Electrostatic Discharge section on page 2 Step 2 Power down the device and all attached devices Disconnect the power cord and all external cables Step 3 Remove the bezel as shown in Figure 1 a Press the releas...

Страница 5: ...ling and airflow replace the cover before turning on the device Operating the device for extended periods over 30 minutes with the cover removed might damage device components Step 6 Before you begin working inside the chassis familiarize yourself with the location of the components that you will be handling Figure 3 shows the front of the chassis and the location of the drive bays behind the beze...

Страница 6: ...s on the appropriate jumper pins as follows Hitachi disks have a single set of jumpers Follow these jumper settings instructions for Hitachi disks Assign SCSI ID 0 to the disk drive in the first drive bay by removing any jumpers from the jumper pins The first drive bay drive bay 0 is located below the CD ROM drive on the left side of your system See Figure 3 Assign SCSI ID 1 to the disk drive in t...

Страница 7: ...e second drive bay drive bay 1 is located below the flash memory card on the right side of your system See Figure 3 Figure 4 shows the connector end of the hard disk drive and the location of the jumper pins Figure 4 Hard Disk Drive Connectors and SCSI ID Jumper Pins Step 2 To check whether the configuration is correct refer to the boot time messages on the device console An example is as follows ...

Страница 8: ...ee Figure 2 Step 6 To remove the hard disk drive in either drive bay work from inside the chassis and disconnect the SCSI cable from the hard disk drive by using your thumbs to work the cable connector out of the drive connector Do not pull directly on the cable itself Tip To remove the hard disk drive in the first bay the bay on the left below the CD ROM drive begin by disconnecting the integrate...

Страница 9: ...ation Step 11 Connect the power and SCSI cables to the drive If you disconnected the IDE cable to the CD ROM reconnect it Step 12 Make sure that your cables are lying flat inside the chassis so that you do not shear them when you replace the chassis cover 1 SCSI connector 2 Jumper pins 3 Power connector 4 Circuit board facing up 5 Drive carrier 6 Carrier handle 151557 1 3 2 5 4 6 ...

Страница 10: ...our installation follow these steps Step 1 Install the cover Place it into position slide it forward and then tighten the captive screw labeled 1 in Figure 2 Caution Before sliding the cover forward make sure that the cover will properly engage the ledge at the front of the device Step 2 Install the bezel as follows a Align the hooks on the bottom of the bezel with the device b Press the bezel tow...

Страница 11: ...ese tasks Report security vulnerabilities in Cisco products Obtain assistance with security incidents that involve Cisco products Register to receive security information from Cisco A current list of security advisories and notices for Cisco products is available at this URL http www cisco com go psirt If you prefer to see advisories and notices as they are updated in real time you can access a Pr...

Страница 12: ...contact your reseller Cisco Technical Support Documentation Website The Cisco Technical Support Documentation website provides online documents and tools for troubleshooting and resolving technical issues with Cisco products and technologies The website is available 24 hours a day at this URL http www cisco com techsupport Access to all tools on the Cisco Technical Support Documentation website re...

Страница 13: ... service request is assigned to a Cisco engineer The TAC Service Request Tool is located at this URL http www cisco com techsupport servicerequest For S1 or S2 service requests or if you do not have Internet access contact the Cisco TAC by telephone S1 or S2 service requests are those in which your production network is down or severely degraded Cisco engineers are assigned immediately to S1 and S...

Страница 14: ... 2 S2 Operation of an existing network is severely degraded or significant aspects of your business operation are negatively affected by inadequate performance of Cisco products You and Cisco will commit full time resources during normal business hours to resolve the situation Severity 3 S3 Operational performance of your network is impaired but most business operations remain functional You and C...

Страница 15: ...go Cisco IOS Cisco Press Cisco Systems Cisco Systems Capital the Cisco Systems logo Cisco Unity Enterprise Solver EtherChannel EtherFast EtherSwitch Fast Step Follow Me Browsing FormShare GigaDrive HomeLink Internet Quotient IOS iPhone IP TV iQ Expertise the iQ logo iQ Net Readiness Scorecard iQuick Study LightStream Linksys MeetingPlace MGX Networkers Networking Academy Network Registrar PIX ProC...

Страница 16: ...16 Installing Hard Disk Drives in the Cisco Wide Area Application Engine 611 78 17404 01 Obtaining Technical Assistance ...

Отзывы: