Cisco CompactFlash Adapter for Bootflash Upgrade Installation Note
78-17277-05
Installing the SP Bootflash Memory Upgrade Kit
Figure 4
SP and RP DIMM Locations on the Supervisor Engine 720
Step 2
Release the SP DIMM from the socket by simultaneously releasing the two locking spring clip tabs on
either side of the DIMM socket. (See
Figure 5
, left view.) The DIMM will flip up in the socket. (See
Figure 5
, right view.)
Step 3
Hold the DIMM by its edges and carefully remove it from the DIMM socket.
Figure 5
Removing the DIMM
Step 4
Immediately place the DIMM in an antistatic bag.
144402
RP Bootflash
SP Bootflash
144403