Introducing the Content Engine

This chapter provides a basic functional overview of the Cisco Content Engine 
500 series and describes the Content Engine hardware, major components, and 
front and back panel indicators and controls. 

This chapter contains the following sections:

Introduction, page 1-1

Functional Description, page 1-7

System Hardware Features, page 1-8

Specifications, page 1-16

Regulatory Compliance, page 1-18

Class A Warning Statements, page 1-19

Introduction

Content Engine 500 series units are Internet content delivery devices that offer 
content caching, hosting, and other content-based services. The Content Engine 
sits on the WAN edge between your small business site, enterprise, or service 
provider network and the Internet.

Содержание CE-507 - Content Engine 507

Страница 1: ...ontrols This chapter contains the following sections Introduction page 1 1 Functional Description page 1 7 System Hardware Features page 1 8 Specifications page 1 16 Regulatory Compliance page 1 18 Class A Warning Statements page 1 19 Introduction Content Engine 500 series units are Internet content delivery devices that offer content caching hosting and other content based services The Content En...

Страница 2: ...nfigured for AC input power whereas the CE 590 DC is configured for DC input power The default factory configuration comes with one power supply installed Note For purposes of simplicity all models of the Content Engine 590 are hereafter referred to jointly as the CE 590 The CE 590 has two internal 36 gigabyte GB Ultra2 LVD SCSI hard drives and an external SCSI port for attaching a six drive Cisco...

Страница 3: ...ower The default factory configuration comes with one power supply installed The CE 560 has two internal 36 GB Ultra2 LVD SCSI hard drives and an external SCSI port for attaching a six drive Cisco Storage Array that increases CE 560 storage capacity by an additional 108 GB 6 x 18 GB In addition the CE 560 has two 10 100BASE T Ethernet Fast Ethernet ports with RJ 45 receptacles Port Ethernet 0 supp...

Страница 4: ...the CE 507 has two 10 100BASE T Ethernet Fast Ethernet ports with RJ 45 receptacles Port Ethernet 0 supports autodetect speed mode and full duplex operation The second port Ethernet 1 is supported in ACNS 4 0 3 software and later releases Table 1 3 lists the storage and memory specifications for the CE 507 Table 1 2 CE 560 Storage and Memory Specifications Specification Description Internal hard d...

Страница 5: ...ts autodetect speed mode and full duplex operation The second port Ethernet 1 is supported in ACNS 4 0 3 software and later releases The CE 560AV and CE 507AV have one internal Ultra2 LVD SCSI hard drive and one analog audio and video card Figure 1 1 shows the Content Engine 560AV and 507AV front panel with an analog audio and video card installed in slot 0 and Figure 1 2 shows the analog audio an...

Страница 6: ...the CE 560AV Content Engine 507AV The Content Engine 507AV is a low end Content Engine that services small business networks and branch office sites LINK CONS ETHERNET 0 ETHERNET 1 SCSI LVD ONLY 100Mbps LINK 100Mbps SLOT 0 SLOT 0 AUDIO OUT VIDEO OUT SLOT 1 SLOT 1 0 1 2 3 33193 To console or PC Serial cable Audio cable Audio adapter cable To TV audio port To TV video port Video cable 55047 Table 1 ...

Страница 7: ...delivery Content Engines with Cisco CDN software are deployed in conjunction with Content Routers and Content Distribution Managers to create a complete Content Delivery Network system The CDN solution offers accelerated content delivery hosting and other content based services The CDN solution addresses the need to distribute and receive high bandwidth media rich content across the Internet or an...

Страница 8: ...requests an object from a web server the router first sends the request to a Content Engine If the Content Engine has a copy of the requested object in storage the Content Engine sends the user the object Otherwise the Content Engine simultaneously obtains the requested objects from the Web server stores a copy of the objects caches them and forwards the objects on to the user By caching web objec...

Страница 9: ...Content Engine 500 Series Front View LINK CONS ETHERNET 0 ETHERNET 1 SCSI LVD ONLY 100Mbps LINK 100Mbps SLOT 0 SLOT 0 SLOT 1 SLOT 1 0 1 2 3 LINK CONS ETHERNET 0 ETHERNET 1 100Mbps LINK 100Mbps 0 1 2 3 Ethernet ports Console port Slot 1 LED Slot 0 LED SCSI LVD only port Slot 1 Slot 0 100Mbps LED Link LED Power indicator System indicator Status LEDs 43905 ...

Страница 10: ...roducing the Content Engine System Hardware Features 1 10 Cisco Content Engine 500 Series Hardware Installation Guide 78 11199 03 Figure 1 4 Content Engine 500 Series AC Rear View 33192 Power switch Power receptacle ...

Страница 11: ...nel ports and receptacles See the front panel in Figure 1 3 and the back panel in Figure 1 4 and Figure 1 5 40911 Power switch Power receptacle Table 1 6 Ports and Receptacles Item Description Front Panel CONS port This serial port connects to a console ETHERNET 0 port The Ethernet 0 cable connects to this port ETHERNET 1 port Supported in ACNS 4 0 3 software and later releases SCSI LVD only port ...

Страница 12: ...0AV only Slot 1 Bay for hard drive 1 Back Panel Power receptacle AC or DC The power cord connects to this plug Power switch This switch toggles between on and off A power light on the front panel when lit indicates that the power is on Table 1 6 Ports and Receptacles continued Item Description Table 1 7 LEDs Indicator Color State Description Power Green On Power is flowing to the Content Engine Sy...

Страница 13: ...n ASCII terminal or a PC running terminal emulation software The console port on the Content Engine is configured as data terminal equipment DTE and uses an RJ 45 connector By attaching an RJ 45 to DB 9 adapter to the rollover cable you create an RJ 45 to DB 9 null modem cable Slot 1 Green On There is no drive installed in Slot 1 Off The drive in Slot 1 is not active Flashing The drive in Slot 1 i...

Страница 14: ...ame color as the pin on the outside of the right connector pin 8 Figure 1 6 Identifying a Rollover Cable by Inspection Network Cables An Ethernet cable is required to connect the Content Engine to your network To connect the Content Engine to your network you must use one of the following types of cables Unshielded twisted pair UTP straight through cable with RJ 45 connectors to connect the Conten...

Страница 15: ...inouts The following pinout information for common cable configurations can assist you in purchasing or building replacement cables Table 1 8 shows the pinout for a straight through 100BASE T cable Table 1 9 shows the pinout for a crossover 100BASE T cable Table 1 8 Straight Through 100BASE T Cable Pinout RJ 45 Pin Signal RJ 45 Pin 1 TX 1 2 TX 2 3 RX 3 4 4 5 5 6 RX 6 7 7 8 8 Table 1 9 Crossover 10...

Страница 16: ...out continued RJ 45 Pin Signal RJ 45 Pin Table 1 10 Specifications Specification Description CPU Pentium III Ethernet controller Intel 82559 SCSI controller Ultra2 SCSI LVD Dimensions Height 1 72 in 43 7 mm Width 17 5 in 44 45 cm Depth 14 13 in 35 8 cm Weight 12 5 lb 5 7 kg AC power Universal input 100 127 VAC 200 240 VAC Frequency 50 60 Hz Maximum power 130W Rated current 120 VAC input with PFC p...

Страница 17: ...a2 LVD Maximum data transfer rate 80 Mbps Maximum station to station cabling distances 10 100BASE TX Ethernet Category 5 UTP 328 ft 100 m SCSI Ultra2 LVD 39 ft 12 m Placement Rack mounted mid front or back standard 19 in 48 26 cm and 23 in 58 42 cm racks Temperature Operating 32 to 104 F 0 to 40 C Nonoperating 13 to 158 F 25 to 70 C Humidity operating 5 to 95 noncondensing Altitude operating 6500 ...

Страница 18: ...rking Safety UL 1950 CSA C22 2 No 950 EN 60950 IEC 60950 EMC FCC Part 15 CFR 47 Class A ICES 003 Class A EN 55022 Class A with UTP cables CISPR22 Class A with UTP cables ASNZ 3548 Class A with UTP cables VCCI Class A with UTP cables EN 55024 EN 50082 1 In addition to the above the Content Engine 500 series units except systems that use the 36 GB hard drive comply with the following requirements EN...

Страница 19: ...sed in a domestic environment radio disturbance may arise Taiwan BSMI This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures Hungary Class A Warning This equipment is a Class A product and should be used and installed properly according to the Hungarian EMC Class A requirements MSZ EN 55022 Clas...

Страница 20: ...ói kézikönyv számára Ez a berendezés A osztályú termék felhasználására és üzembe helyezésére a magyar EMC A osztályú követelményeknek MSZ EN 55022 megfeleloen kerülhet sor illetve ezen A osztályú berendezések csak megfelelo kereskedelmi forrásból származhatnak amelyek biztosítják a megfelelo speciális üzembe helyezési körülményeket és biztonságos üzemelési távolságok alkalmazását ...