Getting Started and Product Document of Compliance for the Cisco Catalyst IW6300 Heavy Duty Series Access Points
Installation Warning and Caution Statements for Hazardous Locations Environments
Installation Warning and Caution Statements for Hazardous
Locations Environments
Warning:
IMPORTANT SAFETY INSTRUCTIONS
Means danger. You are in a situation that could cause bodily injury. Before you work on any equipment, be aware of
the hazards involved with electrical circuitry and be familiar with standard practices for preventing accidents. Use
the statement number provided at the end of each warning to locate its translation in the translated safety warnings
that accompanied this device.
Statement 1071
Warning:
The AC power supply has double pole/neutral fusing.
Statement 188
Warning:
This equipment must be externally grounded using a customer-supplied ground wire before power is
applied. Contact the appropriate electrical inspection authority or an electrician if you are uncertain that suitable
grounding is available.
Statement 366
Warning:
Do not work on the system or connect or disconnect cables during periods of lightning activity.
Statement
1001
Warning:
Read the installation instructions before you connect the system to its power source.
Statement 1004
Warning:
This unit is intended for installation in restricted access areas. A restricted access area can be accessed
only through the use of a special tool, lock and key, or other means of security.
Statement 1017
Warning:
A readily accessible two-poled disconnect device must be incorporated in the fixed wiring.
Statement 1022 (for DC input applications only)
Warning:
Only trained and qualified personnel should be allowed to install, replace, or service this equipment.
Statement 1030
Warning:
Ultimate disposal of this product should be handled according to all national laws and regulations.
Statement 1040
Warning:
For connections outside the building where the equipment is installed, the following ports must be
connected through an approved network termination unit with integral circuit protection.
10/100/1000 Ethernet
Statement 1044
Warning:
When installing or replacing the unit, the ground connection must always be made first and disconnected
last.
Statement 1046.
Warning:
To prevent the system from overheating, do not operate it in an area that exceeds the maximum
recommended ambient temperature of: 75°C (167°F)
Statement 1047
Warning:
Do not locate the antenna near overhead power lines or other electric light or power circuits, or where it
can come into contact with such circuits. When installing the antenna, take extreme care not to come into contact
with such circuits, because they may cause serious injury or death. For proper installation and grounding of the
antenna, please refer to national and local codes (for example, U.S.:NFPA 70, National Electrical Code, Article 810,
Canada: Canadian Electrical Code, Section 54).
Statement 1052
Warning:
In switch installations in a hazardous location, the DC power source could be located away from the
vicinity of the switch. Before performing any of the following procedures, locate the DC circuit to ensure that the
power is removed and cannot be turned on accidentally, or verify that the area is nonhazardous before proceeding.
Statement 1059
Warning:
Do not disconnect connections to this equipment unless power has been removed or you have verified
that the area is nonhazardous. Secure any external connections that mate to this equipment by using screws,
sliding latches, threaded connectors, or other means provided with this product.
Substitution of components may impair suitability for Class I, Division 2.
Statement 1062
Warning:
Use twisted-pair supply wires suitable for 86°F (30°C) above surrounding ambient temperature outside
the enclosure.
Statement 1067