Содержание Catalyst IE-3400H-16FT

Страница 1: ... Hardware Installation Guide First Published 2019 09 03 Last Modified 2019 09 05 Americas Headquarters Cisco Systems Inc 170 West Tasman Drive San Jose CA 95134 1706 USA http www cisco com Tel 408 526 4000 800 553 NETS 6387 Fax 408 527 0883 ...

Страница 2: ... 2019 Cisco Systems Inc All rights reserved ...

Страница 3: ... Panel of the Switch 3 10 100BASE T Ports 3 Power Connector 4 Alarm Connector 4 Console Management Port 5 LEDs 6 System LED 6 Express Setup LED 6 Power Status LEDs 7 Alarm LEDs 7 Port Status LEDs 7 IP67 Power Supply 8 Switch Installation 9 C H A P T E R 2 Switch Installation 9 Preparing for Installation 9 Warnings 9 Cisco Catalyst IE3400 Heavy Duty Series Hardware Installation Guide iii ...

Страница 4: ...orts 20 Where to Go Next 21 Switch Mounting 23 C H A P T E R 3 Switch Mounting 23 Mounting the Switch 23 Installing the Switch on the Wall 23 Troubleshooting 27 C H A P T E R 4 Troubleshooting 27 Diagnosing Problems 27 Switch Connections 27 Switch Performance 28 Resetting the Switch 29 How to Recover Passwords 30 Troubleshooting Express Setup 30 Finding the Switch Serial Number 30 Technical Specif...

Страница 5: ...m Ratings 34 Configuring the Switch 35 C H A P T E R 6 Configuring the Switch 35 Entering the Initial Configuration Information 35 IP Settings 35 Completing the Setup Program 35 Cisco Catalyst IE3400 Heavy Duty Series Hardware Installation Guide v Contents ...

Страница 6: ...Cisco Catalyst IE3400 Heavy Duty Series Hardware Installation Guide vi Contents ...

Страница 7: ...s cautions and warnings Means reader take note Notes contain helpful suggestions or references to materials not contained in this manual Note Means reader be careful In this situation you might do something that could result in equipment damage or loss of data Caution This warning symbol means danger You are in a situation that could cause bodily injury Before you work on any equipment be aware of...

Страница 8: ...g the switch see the product release notes on Cisco com for the latest information See www cisco com en US products ps12451 tsd_products_support_series_home html Cisco Catalyst IE3400 Heavy Duty Series Hardware Installation Guide viii Preface Related Publications ...

Страница 9: ...lation section Note The IE3400 Heavy Duty Series switches are powered by Cisco IOS XE a next generation operating system with built in security and trust featuring Secure Boot image signing and the Cisco Trust Anchor module Cisco IOS XE also provides API driven configuration with open APIs and data models The IE3400 Heavy Duty Series can be managed with powerful tools such as Cisco DNA Center and ...

Страница 10: ...arm output relay Alarm outputs See Note 2 and 3 1 alarm input 1 alarm input 1 alarm input 1 alarm input 1 alarm input 1 alarm input Alarm inputs See Note 2 1 1 1 1 1 1 Console ports See Note 2 Mini change single power source Mini change single power source Mini change single power source Mini change single power source Mini change single power source Mini change single power source Power input Not...

Страница 11: ... 100BASE T ports to operate at 10 or 100 Mb s over IP standard M12 cabling The ports can operate in full duplex half duplex autonegotiate default or never half duplex mode A Never Half Duplex option for a port functions as the name implies the link is never established at half duplex it is either full duplex or no link Never Half Duplex avoids the unpredictable response times that in a CSMA CD net...

Страница 12: ...one alarm output relay The alarm output circuit is a relay with a normally open and a normally closed contact The switch is configured to detect faults that are used to energize the relay coil and change the state on both of the relay contacts normally open contacts close and normally closed contacts open The alarm output relay can be used to control an external alarm device such as a bell or a li...

Страница 13: ... Microsoft Windows or to a terminal server through the 5 pole A coded console port and configure it by using the CLI The baud rate and format of the console port is 9600 baud 8 data bits 1 stop bit No parity None flow control Figure 6 Console Connector RXD 4 RTS 1 GND 5 CTS 2 TXD 3 For specified cable use Cisco Product CAB CONSOLE M12 Note Cisco Catalyst IE3400 Heavy Duty Series Hardware Installat...

Страница 14: ... Express Setup LED The Express Setup LED displays the status of the initial setup for the initial configuration Table 3 Setup LED Status Color Configured as a managed switch Off dark Operating normally running the initial setup configuration Solid green Performing the initial setup in recovery or the initial setup is incomplete Blinking green Failed to start initial setup or recovery because there...

Страница 15: ...nce see the LEDs section Alarm LEDs The following table list the alarm LED colors and their meanings Table 5 Alarm Out Status LEDs System Status Color Alarm out is not configured or the Switch is off Off Alarm out is configured no alarms detected Green Major alarm detected Blinking red Minor alarm detected Red Port Status LEDs Each 10 100BASE T or 10 100 1000Base T port identified by numbers 1 23 ...

Страница 16: ...AC The IP67 DC power supply can take 18 to 60Vdc input and provide a 54V 160W DC output The IP67 AC power supply can take 85 264VAC input and provide a 54V 180W DC output There are also non IP67 power supplies compatible with the switch The power supplies are sold separately Note The following figure displays the IP67 Power Supply Figure 8 Cisco IP67 Power Supply DC input power connector 3 DC outp...

Страница 17: ...Safety Information for this switch Before working on equipment that is connected to power lines remove jewelry including rings necklaces and watches Metal objects will heat up when connected to power and ground and can cause serious burns or weld the metal object to the terminals Statement 43 Warning Do not work on the system or connect or disconnect cables during periods of lightning activity Sta...

Страница 18: ...ording to all national laws and regulations Statement 1040 Warning For connections outside the building where the equipment is installed the following ports must be connected through an approved network termination unit with integral circuit protection 10 100 1000 Ethernet Console and Alarm Statement 1044 Warning To prevent the system from overheating do not operate it in an area that exceeds the ...

Страница 19: ...r must be torqued to the recommended spec before operating the unit For torque specs see Cisco IE 2000 IP67 Series Switches Technical Specifications Caution Use caution when removing dust caps Dust caps in an over tightened state may adhere to the connector O ring seal Ensure that the O ring remains in place when dust caps are removed and follow all torque specs here Cisco IE 2000 IP67 Series Swit...

Страница 20: ...0 8 mm Front 2 0 in 50 8 mm Ambient temperature does not exceed 140 F 60 C Cabling is away from sources of electrical noise such as radios power lines and fluorescent lighting fixtures Verifying Package Contents Included in the box is the switch itself and it s installation documentation If any item is missing or damaged contact your representative or reseller for support Tools and Equipment Obtai...

Страница 21: ...rd against shock and vibration by holding the card in place The cover is attached via lanyard and secured with captive screws The slot for the SD memory card is located on the side of the switch To install or replace the SD memory card follow these steps Procedure Step 1 On the side of the switch loosen the captive screws until they are free of the chassis See the following figure Step 2 Install o...

Страница 22: ...al The program frequently a PC application such as HyperTerminal makes communication between the switch and your PC or terminal possible Step 3 Configure the baud rate and character format of the PC or terminal to match the console port characteristics 9600 baud 8 data bits 1 stop bit No parity None flow control Step 4 Connect power to the switch as described in Connecting to Power on page 14 Step...

Страница 23: ...t is reliably connected to earth ground follow the grounding procedure instructions and use a UL listed ring terminal lug suitable for number 10AWG wire Hollingsworth part number R3456B or equivalent Caution Use at least a 4 mm 2 conductor to connect to the external grounding screw Caution A ground lug is not supplied with the switch You can select from these options Single ring terminal Two singl...

Страница 24: ... the power supply to the earth ground The wire color might differ depending on the country that you are using it in For connections from the power supply to earth ground use 10 to 12 AWG stranded copper wire Note Step 2 Connect one end of the stranded copper wire to a grounded bare metal surface such as a ground bus a grounded DIN rail or a grounded bare rack Connect the other end of the wire to t...

Страница 25: ...C static IP address and temporarily configure your PC settings to use DHCP before going to the next step Step 2 Connect power to the switch See the instructions in the Connecting to Power on page 14 The boot sequence begins This process can take up to 90 seconds During boot fast the SYS LED blinks green and the other LEDs turn steady green When boot fast is complete the SYS LED turns steady green ...

Страница 26: ... In the Account Settings page provide values for all fields with Enter a Login Name Command Line Password should be set to Sync to Login Password from the dropdown menu Date Time is optionally set to NTP Time from the dropdown menu Step 9 Click Basic Settings once the settings are correct The Basic Settings window is displayed Enter an IP address This field is mandatory SSH click the enable box Sc...

Страница 27: ... 2 Enter the switch IP address username and password assigned previously in Step 8 in the web browser and press Enter The WebUI page appears If the WebUI page does not appear Confirm that the port LED for the switch port connected to your network is green Confirm that the PC that you are using to access the switch has network connectivity by connecting it to a well known web server in your network...

Страница 28: ...n or equal to 24 VDC 1 0 A or 48 VDC 0 5 A Caution Connecting Destination Ports These section provides information about connecting to the destination ports IP66 IP67 UL50E Type 4X compliant only when all cables are mated and torqued appropriately or with the supplied dust caps attached Caution Connecting to 10 100 and 10 100 1000 Ports The 10 100 and 10 100 1000 ports automatically configure them...

Страница 29: ...vers the topology and searches for loops This can take up to 30 seconds and then the port LED turns green If the port LED does not turn on The device at the other end might not be turned on There might be a cable problem or a problem with the adapter installed in the attached device See Chapter 4 Troubleshooting for solutions to cabling problems Step 3 Reconfigure and reboot the connected device i...

Страница 30: ... center index html SNMP Switches can be managed by using a SNMP compatible management station running platforms such as HP OpenView or SunNet Manager The switch supports a comprehensive set of Management Information Base MIB extensions and four Remote Monitoring RMON groups Common Industrial Protocol Common Industrial Protocol CIP management objects are supported by the switch allowing you to mana...

Страница 31: ...tch to a wall or a panel follow these steps Read the wall mounting instructions carefully before beginning installation Failure to use the correct hardware or to follow the correct procedures could result in a hazardous situation to people and damage to the system Statement 378 Warning Procedure Step 1 Position the switch mounting bracket against the wall or a panel in the desired location with th...

Страница 32: ...r support structure capable of supporting the weight of the bracket and the switch Note Step 2 Loosly attach the 4 mounting screws to the switch and slide it into the bracket and down See the following figure Cisco Catalyst IE3400 Heavy Duty Series Hardware Installation Guide 24 Switch Mounting Installing the Switch on the Wall ...

Страница 33: ...ting bracket Then the bracket itself can be unscrewed from the wall if necessary What to do next After the switch is mounted on the wall or panel connect the power and alarm wires as described in the Connecting Alarm Circuits section on page 12 Cisco Catalyst IE3400 Heavy Duty Series Hardware Installation Guide 25 Switch Mounting Installing the Switch on the Wall ...

Страница 34: ...Cisco Catalyst IE3400 Heavy Duty Series Hardware Installation Guide 26 Switch Mounting Installing the Switch on the Wall ...

Страница 35: ...ause the port has many packet errors or it constantly flaps loses and regains link Exchange the cable with a known good cable Look for broken or missing pins on cable connectors Rule out any bad patch panel connections or media converters between the source and the destination If possible bypass the patch panel Try the cable in another port to see if the problem follows the cable Link Status Verif...

Страница 36: ...ue Make sure that each switch can identify the end device MAC address in its Content Addressable Memory CAM table Spanning Tree Loops STP loops can cause serious performance issues that look like port or interface problems A unidirectional link can cause loops It occurs when the traffic sent by the switch is received by the neighbor but notification that the traffic was received from the neighbor ...

Страница 37: ...gnment errors verify that the cable distance from the switch to the connected device meets the recommended guidelines Resetting the Switch Resetting the switch deletes the configuration and reboots the switch Reasons why you might want to reset the switch to the factory default settings include You installed the switch in your network and cannot connect to it because it is assigned an unknown IP a...

Страница 38: ...etup button and reconnect the cable to the blinking Ethernet port Did you have a pop up blocker running on your PC when you connected to the switch port If yes disconnect the cable from the switch port disable the proxy settings press the Express Setup button and reconnect the cable to the blinking Ethernet port Did you have proxy settings enabled in your browser software when you connected to the...

Страница 39: ...equiring Enclosures Fan or blower equipped enclosures For example NEMA TS 2 The minimum airflow is 200 lfm1 Note Vented enclosures For example NEMA1 IP66 and IP67 Sealed enclosures For example NEMA4 NEMA4X NEMA12 NEMA13 IP54 and IP66 Enclosure types 1 lfm linear feet per minute The safety certifications apply only to ambient temperatures under 140 F 60 C However the Cisco Catalyst IE3400 Heavy Dut...

Страница 40: ...ype 4x compliant only when all IP67 cables are mated and torqued appropriately or with the supplied dust caps attached Caution Ingress Protection Type Ratings Up to 15 000 feet 4570 meters Operating altitude Up to 40 000 feet 4570 meters Storage altitude Table 10 Power Specifications IE 3400H 24T IE 3400H 16T IE 3400H 8T IE 3400H 24FT IE 3400H16FT IE 3400H 8FT PowerSpecifications 12 to 48VDC 12 to...

Страница 41: ...tches are below Table 12 Cisco Catalyst IE3400 Heavy Duty Series Cables and Connectors Copper 100 Base T M12 D coded 4 pole pin cable M12 Male and or M12 RJ 45 connector Copper GE M12 X coded 8 pole pin shielded cable M12 Male and or M12 RJ 45 connector Data Ports Copper M12 A Coded 5 Pin connector Alarm Port Mini Style 4 pin connector for power input Power Input Console Cable 6ft with M12 and DB9...

Страница 42: ...eavy Duty Series switches are below Table 14 Cisco Catalyst IE3400 Heavy Duty Series Alarm Ratings Specification Alarm Ratings One alarm output relay using an M12 A Coded 5 Pin connector Max rated 24VDC 1A 48VDC 0 5A Alarm Cisco Catalyst IE3400 Heavy Duty Series Hardware Installation Guide 34 Technical Specifications Alarm Ratings ...

Страница 43: ...s powered on You must assign an IP address and other configuration information necessary for the switch to communicate with the local routers and the Internet This information is also required if you plan to use Device Manager or Cisco Network Assistant to configure and manage the switch IP Settings You need this information from your network administrator before you complete the setup program Swi...

Страница 44: ...lnet password and press Return The password can be from 1 to 25 alphanumeric characters is case sensitive allows spaces but ignores leading spaces Enter virtual terminal password terminal password 1 Optional Configure Simple Network Management Protocol SNMP by responding to the prompts You can also configure SNMP later through the CLI Device Manager or the Cisco Network Assistant application To co...

Страница 45: ...mmand prompt without saving this config 1 Return back to the setup without saving this config 2 Save this configuration to nvram and exit If you want to save the configuration and use it the next time the switch reboots save it in NVRAM by selecting option 2 Enter your selection 2 2 Make your selection and press Return After you complete the setup program the switch can run the default configurati...

Страница 46: ...Cisco Catalyst IE3400 Heavy Duty Series Hardware Installation Guide 38 Configuring the Switch Completing the Setup Program ...