B-6
Catalyst 2960 Switch Hardware Installation Guide
OL-7075-09
Appendix B Connector and Cable Specifications
Cable and Adapter Specifications
Two Twisted-Pair Cable Pinouts
Figure B-5
and
Figure B-6
show the schematics of two twisted-pair cables for connecting to 10BASE-T-
and 100BASE-TX-compatible devices.
Figure B-5
Two Twisted-Pair Straight-Through Cable Schematic
Figure B-6
Two Twisted-Pair Crossover Cable Schematic
Four Twisted-Pair Cable Pinouts for 1000BASE-T Ports
Figure B-7
and
Figure B-8
show the schematics of four twisted-pair cables for 10/100/1000 ports on
Catalyst 2960 switches.
Figure B-7
Four Twisted-Pair Straight-Through Cable Schematic for 10/100/1000 Ports
Switch
3 TD+
6 TD–
1 RD+
2 RD–
Router or PC
3 RD+
6 RD–
1 TD+
2 TD–
H5578
Switch
3 TD+
6 TD–
1 RD+
2 RD–
Switch
3 TD+
6 TD–
1 RD+
2 RD–
H5579
1 TPO+
2 TPO-
3 TP1+
6 TP1-
1 TP1+
Switch
Router or PC
2 TP1-
3 TPO+
6 TPO-
4 TP2+
5 TP2-
7 TP3+
8 TP3-
4 TP3+
5 TP3-
7 TP2+
8 TP2-
65272