background image

Figure 37: Obtaining the IP Address

It may take up to three mins. You must complete the Day 0 setup through the web UI before using the device
terminal.

Step 4

Launch a web browser on the PC and enter the device IP address (

https://192.168.1.1

) in the address

bar.

Step 5

Enter the Day 0

username

webui

and

password

serial number

of the switch. Note that the serial

number is case sensitive.

The Day 0 username and password depends on the software version of your switch.

For Cisco Catalyst switches running software versions earlier than Cisco IOS XE Fuji 16.9.x, the
default username is

webui

; the default password is the serial number of the switch chassis.

For Cisco Catalyst switches running software version Cisco IOS XE Amsterdam 17.1.x, the default
username is

webui

; the default password is

cisco

.

Note

What to do next

Create a user account.

Cisco Catalyst 9200 Series Switches Hardware Installation Guide

56

Configuring the Switch

Connecting to the Switch

Содержание C9200L-24P-4G

Страница 1: ...adquarters Cisco Systems Inc 170 West Tasman Drive San Jose CA 95134 1706 USA http www cisco com Tel 408 526 4000 800 553 NETS 6387 Fax 408 527 0883 Questo manuale d istruzione è fornito da trovaprezzi it Scopri tutte le offerte per Cisco Catalyst C9200 L C9200L 24T 4X A o cerca il tuo prodotto tra le migliori offerte di Switch ...

Страница 2: ... 2018 2020 Cisco Systems Inc All rights reserved ...

Страница 3: ... Tag 9 StackWise Ports 9 Power Supply Modules 9 Fan Modules 11 Ethernet Management Port 12 RJ 45 Console Port 12 Network Configurations 13 Installing the Switch 15 C H A P T E R 2 Preparing for Installation 15 Safety Warnings 15 Installation Guidelines 17 Shipping Box Contents 17 Tools and Equipment 18 Verifying Switch Operation 18 Planning a Switch Data Stack 19 Cisco Catalyst 9200 Series Switche...

Страница 4: ...1 Installing a Network Module 33 C H A P T E R 3 Installing a Network Module in the Switch 33 Safety Warnings 33 Equipment That You Need 33 Installing a Network Module 34 Removing a Network Module 36 Finding the Network Module Serial Number 36 Installing and Removing Pluggable Transceiver Modules 37 Installing a Cisco Pluggable Transceiver Module 37 Removing a Cisco Pluggable Transceiver Module 39...

Страница 5: ... DNS and SNMP Settings 65 Configuring Port Settings 66 Configuring VTY Lines 67 Configuring the Switch Using the CLI 68 Accessing the CLI Through the Console Port 68 Connecting the RJ 45 Console Port 68 Connecting the USB Console Port 69 Installing the Cisco Microsoft Windows USB Device Driver 70 Installing the Cisco Microsoft Windows 7 USB Driver 70 Uninstalling the Cisco Microsoft Windows USB Dr...

Страница 6: ...D 80 MASTER LED 80 STACK LED 81 PoE LED 82 Port LEDs and Modes 82 Beacon LED 84 RJ 45 Console Port LED 85 Fan LED 85 Uplink Port LEDs 85 Introduction Cisco Catalyst 9200 Series Switches Hardware Installation Guide vi Contents ...

Страница 7: ... fixed fans supports StackWise 80 C9200L 24P 4X Stackable 24x1G ports 4x1G SFP fixed uplink ports 2 power supply slots 2 fixed fans supports StackWise 80 C9200L 24T 4G Stackable 24x1G ports 4x10G SFP fixed uplink ports 2 power supply slots 2 fixed fans supports StackWise 80 C9200L 24T 4X Stackable 48x1G PoE ports 4x1G SFP fixed uplink ports 2 power supply slots 2 fixed fans supports StackWise 80 C...

Страница 8: ... slots 2 fixed fans supports StackWise 80 C9200L 48PL 4X Table 2 C9200 Switch Models and Descriptions Description Switch Model Stackable 24x1G PoE ports 4x1G and 4x10G network modules for uplink ports 2 power supply slots 2 field replaceable fans supports StackWise 160 C9200 24P Stackable 24x1G PoE ports 4x1G and 4x10G network modules for uplink ports 2 power supply slots 2 field replaceable fans ...

Страница 9: ...uplink ports 2 power supply slots 2 field replaceable fans supports StackWise 160 C9200 48PL Front Panel Components This section describes the front panel components of Cisco Catalyst 9200 Series switches 24 or 48 downlink ports of one of the following types 10 100 1000 10 100 1000 PoE 1G 10G Uplink ports USB Type A storage ports USB mini Type B console port LEDs Blue Beacon All the switch models ...

Страница 10: ...raffic can use Category 3 cable or higher PoE and PoE Ports The PoE and PoE ports provide the following functionality PoE PoE ports Support for IEEE 802 3af compliant powered devices up to 15 4W PoE per port and support for IEEE 802 3at compliant powered devices up to 30W PoE per port Support for pre standard Cisco powered devices Configurable support for Cisco intelligent power management includi...

Страница 11: ...45 crossover or straight through cable The RJ 45 console port connection uses the supplied RJ 45 to DB 9 female cable The USB console port connection uses a USB Type A to 5 pin mini Type B cable The USB console interface speeds are the same as the RJ 45 console interface speeds If you use the USB mini Type B console port the Cisco Windows USB device driver must be installed on any PC connected to ...

Страница 12: ...he flash device with a FAT file system It provides you with the ability to automatically upgrade the internal flash with the USB drive s configuration and image for emergency switch recovery using USB auto upgrade This feature checks the internal flash for a bootable image and configuration and if either image or the configuration is not available then the USB drive is checked for boot images and ...

Страница 13: ...upports a 1G or 10G connection Any combination of standard SFP modules is supported This module is supported on both 1G and Multigigabit Ethernet switch models of C9200 switches C9200 NM 4X This module has two 25 Gigabit Ethernet SFP28 module slots Any combination of SFP SFP and SFP28 modules are supported This module is supported only on C9200 Multigigabit Ethernet switches C9200 NM 2Y This modul...

Страница 14: ...RJ 45 10 100 1000 management port 5 Fixed fan modules on C9200L switches 2 StackWise 80 port connectors 6 Power supply module slots 3 Figure 6 Rear Panel of a C9200 Switch Blue Beacon LED 4 RJ 45 console port 1 MGMT RJ 45 10 100 1000 management port 5 Modular fan modules on C9200 switches 2 Cisco Catalyst 9200 Series Switches Hardware Installation Guide 8 Product Overview Rear Panel ...

Страница 15: ...ved Cisco cables or equipment Caution Power Supply Modules The switch has a field replaceable main AC power supply module and a redundant hot swappable field replaceable AC power supply module The switch is powered through one or two internal power supply modules In switches with PoE capability the redundant power supply can also be used for extra PoE power Following are the power supply modules s...

Страница 16: ...ailable POE budget is 370W and 740W if there are two power supplies installed The following tables show the PoE available and PoE requirements for PoE switch models Table 4 Available PoE with AC Power Supply Full PoE with Redundant Power Supply Available PoE Default Power Supply Models C9200 Switches 740W 370W PWR C5 600WAC or PWR C6 600WAC C9200 24P 1440W 740W PWR C5 1KWAC or PWR C6 1KWAC C9200 4...

Страница 17: ... AC OK Output is disabled or input is outside operating range AC LED is off Off No AC input power Off Power output to switch active Green AC input power present Green Output has failed Red Fan Modules The Cisco Catalyst 9200 Series Switches supports two internal fixed 12 V fan modules and two field replaceable fan modules C9200 FAN The C9200 models support modular fans whereas the C9200L models pr...

Страница 18: ...or straight through cable The 10 100 1000 Ethernet management port is an RJ 45 connector that should be connected to a Windows workstation or a terminal server Do not connect this port to another port in the same switch or to any port within the same switch stack Note The following table shows the Ethernet management port LED colors and their meanings Table 6 Ethernet Management Port LED Descripti...

Страница 19: ...ctive Off Network Configurations See the switch software configuration guide for network configuration concepts and examples of using the switch to create dedicated network segments and interconnecting the segments through Fast Ethernet and Gigabit Ethernet connections Cisco Catalyst 9200 Series Switches Hardware Installation Guide 13 Product Overview Network Configurations ...

Страница 20: ...Cisco Catalyst 9200 Series Switches Hardware Installation Guide 14 Product Overview Network Configurations ...

Страница 21: ...ation guide on Cisco com Before working on equipment that is connected to power lines remove jewelry including rings necklaces and watches Metal objects will heat up when connected to power and ground and can cause serious burns or weld the metal object to the terminals Statement 43 Warning Do not stack the chassis on any other equipment If the chassis falls it can cause severe bodily injury and e...

Страница 22: ...ons must be removed to de energize the unit Statement 1028 Warning Only trained and qualified personnel should be allowed to install replace or service this equipment Statement 1030 Warning Ultimate disposal of this product should be handled according to all national laws and regulations Statement 1040 Warning To prevent the system from overheating do not operate it in an area that exceeds the max...

Страница 23: ...ssembly the temperature around it might be greater than normal room temperature Humidity around the switch does not exceed 95 percent Altitude at the installation site is not greater than 10 000 feet Cooling mechanisms such as fans and blowers in the switch can draw dust and other particles causing contaminant buildup inside the chassis which can result in system malfunction You must install this ...

Страница 24: ...ad screw 5 Power cord retainer 13 4 number 10 pan head screws 6 8 number 8 Phillips flat head screws 7 1 Item is orderable Tools and Equipment Obtain these necessary tools A Number 2 Phillips screwdriver Verifying Switch Operation Before you install the switch in a rack or on a table or shelf power on the switch and verify that it passes POST To power on the switch plug one end of the AC power cor...

Страница 25: ...is not ordered with stacking the adapters must be ordered separately and installed Before connecting the switches in a stack observe these stacking guidelines Number of switches in the stack You can create data stacks with up to eight switches in a stack Length of the cable Order the appropriate cable from your Cisco sales representative The length of the cable depends on your configuration These ...

Страница 26: ...nd the switch as depicted in the image Note Data Stack Cabling Configurations This is an example of a recommended configuration that uses the supplied 0 5 meter StackWise cable In this example the switches are stacked in a vertical rack or on a table This configuration provides redundant Cisco Catalyst 9200 Series Switches Hardware Installation Guide 20 Installing the Switch Data Stack Cabling Con...

Страница 27: ...ure 10 Data Stacking in a Side by Side Mounting Data Stack Bandwidth and Partitioning Examples This section provides examples of data stack bandwidth and possible data stack partitioning The figure shows a data stack of switches that provides full bandwidth and redundant StackWise cable connections Figure 11 Example of a Data Stack with Full Bandwidth Connections This figure shows an example of a ...

Страница 28: ...ure 13 Example of a Data Stack with a Failover Condition In this figure link 2 is bad Therefore this stack partitions into two stacks and the top and bottom switches become the active switch in the stack If the bottom switch is a member not active or standby switch it reloads Figure 14 Example of a Partitioned Data Stack with a Failover Condition Cisco Catalyst 9200 Series Switches Hardware Instal...

Страница 29: ...ting partial ring stacks are connected together using a stack cable a stack merge can take place This situation reloads the whole stack all switches in the stack If some switches in the stack are completely separated from the stack a stack split can occur A stack split can occur on a full ring stack if More than one running switch is removed without powering down More than one stack cable is remov...

Страница 30: ...t in the rack When mounting this unit in a partially filled rack load the rack from the bottom to the top with the heaviest component at the bottom of the rack If the rack is provided with stabilizing devices install the stabilizers before mounting or servicing the unit in the rack Statement 1006 Warning Figure 15 Rack Mounting Brackets This figure shows the standard 19 inch brackets and other opt...

Страница 31: ...If required while mounting you can use the additional four screws provided in the accessory kit Procedure Use two Phillips flat head screws to attach the long side of the bracket to each side of the switch for the front or rear mounting positions The following illustration shows a C9200L switch C9200 switches follow the same method for installing the rack mount bracket Cisco Catalyst 9200 Series S...

Страница 32: ... front mount position Figure 17 Attaching Brackets for 19 inch Racks in a two post rack rear mount position Number 8 Phillips flat head screws 2 Cisco Catalyst 9200 Series Switches Hardware Installation Guide 26 Installing the Switch Attaching the Rack Mount Brackets ...

Страница 33: ...tion 3 Phillips machine screw black 1 Number 12 or number 10 Phillips machine screws 4 Cable guide 2 Installing the Switch on a Table or Shelf Procedure Step 1 To install the switch on a table or shelf locate the adhesive strip with the rubber feet in the mounting kit envelope Step 2 Attach the four rubber feet to the four circular etches on the bottom of the chassis Cisco Catalyst 9200 Series Swi...

Страница 34: ...figure the switch For more information see Setting up the Switch topic Connect to the front panel ports Connecting to the StackWise Ports Before you begin Before connecting the StackWise cables read the Planning a Switch Data Stack section Always use a Cisco approved StackWise cable to connect the switches Procedure Step 1 Remove the dust covers from the StackWise cables and StackWise ports and st...

Страница 35: ...them for future use Step 3 Install a StackWise adapter in each destination StackWise port and secure it in place using the supplied Torx T15 key or a Torx T15 screwdriver Figure 20 Installing the StackWise Adapter in a StackWise Port StackWise port 2 StackWise adapter 1 Step 4 Connect the cable to the StackWise port on the switch rear panel a Align the StackWise cable connector with the StackWise ...

Страница 36: ...and installing the StackWise cable can shorten its useful life Do not remove and insert the cable more often than is absolutely necessary installing and removing it up to 200 times is supported Caution When you need to remove the StackWise cable from the connector make sure to fully unscrew the correct screws When the connectors are not being used replace the dust covers Cisco Catalyst 9200 Series...

Страница 37: ...ed device If the attached device does not support autonegotiation you can manually set the switch interface speed and duplex parameters With auto MDIX the switch detects the required cable type for copper Ethernet connections and configures the interface accordingly If auto MDIX is disabled use the guidelines in this table to select the correct cable Table 9 Recommended Ethernet Cables When Auto M...

Страница 38: ...area can be accessed only through the use of a special tool lock and key or other means of security Statement 1072 Warning Voice over IP VoIP service and the emergency calling service do not function if power fails or is disrupted After power is restored you might have to reset or reconfigure equipment to regain access to VoIP and the emergency calling service In the USA this emergency number is 9...

Страница 39: ...odule Proper ESD protection is required whenever you handle equipment Installation and maintenance personnel should be properly grounded by grounding straps to eliminate the risk of ESD damage to the equipment Equipment is subject to ESD damage whenever you remove it Caution Only trained and qualified personnel should be allowed to install replace or service this equipment Statement 1030 Warning D...

Страница 40: ...another network module or a blank module The switch complies with EMC safety and thermal specifications when a network module is present If no uplink ports are required install a blank network module Note Before you begin When installing network modules observe these precautions Do not remove the blank module from the slot unless you are installing a network module A module must be in the uplink s...

Страница 41: ...ers Always remove any cables and transceiver modules before you install the network module Caution A module interface might become error disabled when a network module with connected fiber optic cables is installed or removed If an interface is error disabled you can reenable the interface by using the shutdown and no shutdown interface configuration commands Caution Step 4 Position the module fac...

Страница 42: ...tic cables is installed or removed If an interface is error disabled you can reenable the interface by using the shutdown and no shutdown interface configuration commands Caution Step 2 Disconnect the cables from the pluggable transceiver module Step 3 Remove the pluggable transceiver module from the network module Step 4 Loosen the captive screws that hold the network module in place until it com...

Страница 43: ...stalling removing cabling and troubleshooting transceiver modules see the module documentation that shipped with your device Class 1 laser product Statement 1008 Warning Do not remove the dust plugs from the transceiver modules or the rubber caps from the fiber optic cable until you are ready to connect the cable The plugs and caps protect the module ports and cables from contamination and ambient...

Страница 44: ... identify the top of the transceiver module On some transceiver modules the send and receive TX and RX markings might be shown by arrows that show the direction of the connection Step 3 If the transceiver module has a bale clasp latch move it to the open unlocked position Step 4 Align the module in front of the slot opening and push until you feel the connector snap into place Figure 24 Installing...

Страница 45: ...cal ports of the transceiver module to keep the optical interfaces clean Step 4 If the module has a bale clasp latch pull the bale out and down to eject the module If you cannot use your finger to open the latch use a small flat blade screwdriver or other long narrow instrument to open it Step 5 Grasp the transceiver module and carefully remove it from the slot Step 6 Place the transceiver module ...

Страница 46: ...Cisco Catalyst 9200 Series Switches Hardware Installation Guide 40 Installing a Network Module Removing a Cisco Pluggable Transceiver Module ...

Страница 47: ...ns All switches ship with a blank cover in the second power supply slot The main module is field replaceable and the redundant module is hot swappable The redundant power supply can also be used for extra PoE power The following table describes the supported internal power supply modules Table 10 Power Supply Module Part Numbers and Descriptions Description Part Number 125 W AC power supply module...

Страница 48: ...age 9 The power supply modules are autoranging units that support input voltages between 100 and 240 VAC Each AC power supply module has a power cord for connection to an AC power outlet The modules use an 18 AWG power cord The following illustrations show the power supply modules Figure 26 1000W AC Power Supply Cisco Catalyst 9200 Series Switches Hardware Installation Guide 42 Installing a Power ...

Страница 49: ...ctor 2 If no power supply is installed in a power supply slot install a power supply slot cover Figure 28 Power Supply Slot Cover Retainer clips 2 Release handles 1 Cisco Catalyst 9200 Series Switches Hardware Installation Guide 43 Installing a Power Supply Unit Power Supply Modules Overview ...

Страница 50: ...ed Red Finding the Power Supply Module Serial Number If you contact Cisco Technical Assistance regarding a power supply module you need to know the serial number See the following illustrations to find the serial number You can also use the CLI to find out the serial number Figure 29 AC Power Supply Serial Number Cisco Catalyst 9200 Series Switches Hardware Installation Guide 44 Installing a Power...

Страница 51: ...lated with either a power supply or a blank module Caution This equipment must be grounded Never defeat the ground conductor or operate the equipment in the absence of a suitably installed ground conductor Contact the appropriate electrical inspection authority or an electrician if you are uncertain that suitable grounding is available Statement 1024 Warning Blank faceplates and cover panels serve...

Страница 52: ...power supply slot open for more than 90 seconds while the switch is operating Caution This unit might have more than one power supply connection All connections must be removed to de energize the unit Statement 1028 Warning Step 5 Insert the new power supply into the power supply slot and gently push it into the slot When correctly inserted the power supplies excluding the power cord retainer are ...

Страница 53: ...ion the retainer closest to the power supply Depending on the width of the power cord adjust the size of the retainer clamp if required Note c Press the tabs on the retainer clamp towards each other to secure the AC power cord Step 7 Connect the power cord to the power supply and to an AC power outlet Turn on the power at the power source Step 8 Confirm that the power supply AC OK and PS OK LED ar...

Страница 54: ...Cisco Catalyst 9200 Series Switches Hardware Installation Guide 48 Installing a Power Supply Unit Installing or Replacing an AC Power Supply Module ...

Страница 55: ...umber on page 51 Fan Modules Overview Cisco Catalyst 9200 C9200 Series switches support two field replaceable fan modules providing N 1 redundancy support The switch should be able to operate at ambient temperature if one of the fans fails Figure 32 Fan Module Retainer clip 3 Extraction handles 1 Fan LED 2 Cisco Catalyst 9200 Series Switches Hardware Installation Guide 49 ...

Страница 56: ...lling a Fan Module Procedure Step 1 Pinch the fan module release handle and slide the module out You should replace the fan module within 5 minutes to avoid overheating the switch Caution Step 2 Install the fan module in the fan slot and firmly push it into the slot applying pressure to the end of the module not the extraction handles When correctly inserted the fan module is flush with the switch...

Страница 57: ...rding a fan module you need to know the fan module serial number See the following illustration to find the serial number Figure 34 Fan Module Serial Number Cisco Catalyst 9200 Series Switches Hardware Installation Guide 51 Installing a Fan Module Finding the Fan Module Serial Number ...

Страница 58: ...Cisco Catalyst 9200 Series Switches Hardware Installation Guide 52 Installing a Fan Module Finding the Fan Module Serial Number ...

Страница 59: ...t image so there is no need to enable anything or install any license on the device You can use WebUI to build configurations and to monitor and troubleshoot the device without having CLI expertise Connecting to the Switch Before you begin Set up the DHCP Client Identifier on the client to get the IP address from the switch and to be able to authenticate with Day 0 login credentials Setting up the...

Страница 60: ...configuration to take effect Setting up the DHCP Client Identifier on the client for MAC 1 Go to System Preferences Network Advanced TCP DHCP Client ID and enter webui Cisco Catalyst 9200 Series Switches Hardware Installation Guide 54 Configuring the Switch Connecting to the Switch ...

Страница 61: ...ng tasks instead Procedure Step 1 Make sure that no devices are connected to the switch Step 2 Connect one end of an ethernet cable to one of the downlink non management ports on the active supervisor and the other end of the ethernet cable to the host PC MAC Step 3 Set up your PC MAC as a DHCP client to obtain the IP address of the switch automatically You should get an IP address within the 192 ...

Страница 62: ...ensitive The Day 0 username and password depends on the software version of your switch For Cisco Catalyst switches running software versions earlier than Cisco IOS XE Fuji 16 9 x the default username is webui the default password is the serial number of the switch chassis For Cisco Catalyst switches running software version Cisco IOS XE Amsterdam 17 1 x the default username is webui the default p...

Страница 63: ... IOS XE Fuji 16 9 x the default username is webui the default password is the serial number of the switch chassis Step 2 Set a password of up to 25 alphanumeric characters The username password combination you set gives you privilege 15 access The string cannot start with a number is case sensitive and allows spaces but ignores leading spaces Figure 38 Create Account Choosing Setup Options Select ...

Страница 64: ...ou enter Step 4 Optionally enter an IP address to specify the default gateway Step 5 To enable access to the device using telnet check the Telnet check box Step 6 To enable secure remote access to the device using Secure Shell SSH check the SSH check box Step 7 Check the VTP transparent mode check box to disable the device from participating in VTP If you did not select Wired Network in the earlie...

Страница 65: ...witch to route packets between subnets and VLANs Table 12 Default Configuration Loaded with Each Site Profile Access Switches Single Access Switch Redundant Port Channel Uplink Single Access Switch Single Port Channel Uplink Single Access Switch Single Uplink Setting The hostname or device name you provided as part of Quick Setup The hostname or device name you provided as part of Quick Setup The ...

Страница 66: ...t policy created IPv6 host policy created IPv6 host policy created IPv6 Host Policy Auto QoS Policy for Access defined Auto QoS Policy for Access defined Auto QoS Policy for Access defined QoS Policy for Downlink Ports QoS Policy for Distribution created QoS Policy for Distribution created QoS Policy for Distribution created QoS Policy for Uplink Ports Selected ports configured as Port channel in ...

Страница 67: ...ostname or device name you provided as part of Quick Setup The hostname or device name you provided as part of Quick Setup The hostname or device name you provided as part of Quick Setup Hostname RPVST RPVST RPVST Spanning Tree Mode Mode Transparent Mode Transparent Mode Transparent VTP Enabled Enabled Enabled UDLD Recovery mode set to Auto Recovery mode set to Auto Recovery mode set to Auto Error...

Страница 68: ... on the management port based on Quick Setup Layer 3 settings configured on the management port based on Quick Setup Management Interface QoS Policy for Distribution defined QoS Policy for Distribution defined QoS Policy for Distribution defined QoS Policy Selected uplink ports connect to other distribution or core switches Selected uplink ports connect to other distribution or core switches Selec...

Страница 69: ...tname or device name you provided as part of Quick Setup The hostname or device name you provided as part of Quick Setup Hostname Enabled Enabled UDLD Recovery mode set to Auto Recovery mode set to Auto Error Disable Recovery Source Destination IP Source Destination IP Port Channel Load Balance Version 2 Version 2 SSH Enabled Enabled SCP Enabled Enabled VTY Access to Switch Cisco Catalyst 9200 Ser...

Страница 70: ... QoS Policy Selected uplink ports connect to MAN WAN device Selected uplink ports connect to MAN WAN device Uplink Interfaces Downlink connections to distribution switches Downlink connections to access switches Downlink Interfaces Selected ports connect to other core switches Selected ports connect to other core switches Cross connect Interfaces Figure 45 Site Profile Core Switches Configuring Sw...

Страница 71: ...er from the drop down list Figure 46 VLAN and STP Settings Configuring DHCP NTP DNS and SNMP Settings Procedure Step 1 In the Domain Details section enter a domain name that the software uses to complete unqualified hostnames Step 2 Type an IP address to identify the DNS server This server is used for name and address resolution on your device Step 3 In the Server Details section type the IP addre...

Страница 72: ...ep which is displayed in the left pane select the Port Role from among the following options Uplink For connecting to devices towards the core of the network Downlink For connecting to devices further down in the network topology Access For connecting guest devices that are VLAN unaware Step 2 Choose an option from the Select Switch drop down list Step 3 Make selections from the Available list of ...

Страница 73: ...is used The number of VTY lines is the maximum number of simultaneous access to the device remotely If the device is not configured with sufficient number of VTY lines users might face issues with connecting to the WebUI You must change the default value for VTY Line 0 15 or 0 4 in some models to 0 30 to allow up to thirty simultaneous sessions Cisco Catalyst 9200 Series Switches Hardware Installa...

Страница 74: ...witch to your PC or workstation and accessing the switch through a terminal emulation program If you have stacked your switches connect to the console port of one of the switches in the stack You can initially configure the entire stack from any member switch Note Connecting the RJ 45 Console Port Procedure Step 1 Connect the RJ 45 to DB 9 adapter cable to the 9 pin serial port on the PC Connect t...

Страница 75: ...B driver See Installing the Cisco Microsoft Windows USB Device Driver on page 70 USB Type A port on the switch provides file system support and is NOT a console port See USB Type A Port section Note Step 2 Connect a USB cable to the PC USB port Connect the other end of the cable to the switch mini B 5 pin connector USB console port Step 3 Start the terminal emulation program on the PC or the termi...

Страница 76: ...nt Control warning appears click Allow I trust this program to proceed Note Step 5 The InstallShield Wizard Completed window appears Click Finish Step 6 Connect the USB cable to the PC and the switch console port The USB console port LED turns green and the Found New Hardware Wizard appears Follow the instructions to complete the driver installation Uninstalling the Cisco Microsoft Windows USB Dri...

Страница 77: ...hen the InstallShield Wizard Completed window appears click Finish Cisco Catalyst 9200 Series Switches Hardware Installation Guide 71 Configuring the Switch Uninstalling the Cisco Microsoft Windows 7 USB Driver ...

Страница 78: ...Cisco Catalyst 9200 Series Switches Hardware Installation Guide 72 Configuring the Switch Uninstalling the Cisco Microsoft Windows 7 USB Driver ...

Страница 79: ...ge temperature 5 to 90 noncondensing Relative humidity Up to 10 000 ft 3000 m Operating altitude Up to 15 000 ft 4500 m Storage altitude 2 Minimum ambient temperature for cold start is 32 F 0 C This table describes the environmental specifications Table 16 Environmental Specifications for the Power Supplies Environmental Ranges 23 F to 113 F 5 C to 45 C up to 5000 feet 1500m 23 F to 104 F 5 C to 4...

Страница 80: ...5 x 13 8 in 4 4 x 44 4 x 35 cm C9200 48T 1 73 x 17 5 x 15 4 in 4 4 x 44 4 x 39 1 cm C9200 24PXG 1 73 x 17 5 x 13 8 in 4 4 x 44 4 x 35 cm C9200 24PXG 1 73 x 17 5 x 15 4 in 4 4 x 44 4 x 39 1 cm C9200 48PXG 1 73 x 17 5 x 13 8 in 4 4 x 44 4 x 35 cm C9200 48PXG 1 73 x 17 5 x 12 9 in 4 4 x 44 5 x 32 9 cm C9200L 24P 4G 1 73 x 17 5 x 11 3 in 4 4 x 44 5 x 28 8 cm C9200L 24P 4G 1 73 x 17 5 x 12 9 in 4 4 x 4...

Страница 81: ...5 x 13 8 in 4 4 x 44 5 x 35 cm C9200L 24PXG 2Y 1 73 x 17 5 x 15 4 in 4 4 x 44 5 x 39 1 cm C9200L 48PXG 4X 1 73 x 17 5 x 13 8 in 4 4 x 44 5 x 35 cm C9200L 48PXG 4X 1 73 x 17 5 x 15 4 in 4 4 x 44 5 x 39 1 cm C9200L 48PXG 2Y 1 73 x 17 5 x 13 8 in 4 4 x 44 5 x 35 cm C9200L 48PXG 2Y Weight measurement is calculated with one power supply installed Table 18 Weight Measurements Weight Switch Model 11 lb 5...

Страница 82: ...ns Table 19 Physical Specifications for the Power Supplies Weight 1 5 lb 0 68 kg PWR C5 125WAC 1 7 lb 0 77 kg PWR C5 600WAC 2 lb 0 9 kg PWR C5 1KWAC 1 5 lb 0 68 kg PWR C6 125WAC 1 7 lb 0 77 kg PWR C6 600WAC 2 lb 0 9 kg PWR C6 1KWAC Dimensions H x D x W The dimensions shown include the extraction handle and the keying feature 1 58 x 4 0 x 7 6 in 40 1 X 101 6 X 193 mm PWR C5 125WAC PWR C5 600WAC PWR...

Страница 83: ... C5 125WAC and PWR C6 125WAC 12V 10 5A PWR C5 600WAC and PWR C6 600WAC 54V 11 1A PWR C5 1KWAC and PWR C6 1KWAC 54V 16 5A Output ratings PWR C5 125WAC and PWR C6 125WAC 426 5 BTUs per hour 125W PWR C5 600WAC and PWR C6 600WAC 2047 3 BTUs per hour 600W PWR C5 1KWAC and PWR C6 1KWAC 3412 BTUs per hour 1000W Total output BTU Table 21 Fan Module Environmental and Physical Specifications Environmental R...

Страница 84: ...ical Specification 1 62 x 1 73 x 4 24 in 4 11 x 4 39 x 10 76 cm Dimensions H x D x W 0 48 lb 0 21 kg Weight for three fans Operating Specification 20 cfm Airflow Cisco Catalyst 9200 Series Switches Hardware Installation Guide 78 Technical Specifications Technical Specifications ...

Страница 85: ...Beacon LED on page 84 RJ 45 Console Port LED on page 85 Fan LED on page 85 Uplink Port LEDs on page 85 LEDs You can use the switch LEDs to monitor switch activity and its performance Figure 51 Switch Front Panel LEDs Console LED The console LED indicates whether the USB console port or the bluetooth console is enabled Cisco Catalyst 9200 Series Switches Hardware Installation Guide 79 ...

Страница 86: ...ning properly Amber There is a fault with one of the following Network module non traffic related Power supply Fan module Blinking amber MASTER LED Table 24 MASTER LED Description Color Switch is not the master switch Off Switch is the stack master or a standalone switch Green Switch is in stack standby mode Fast blinking green An error occurred when the switch was selecting the stack master switc...

Страница 87: ...nding port LEDs will blink green for each switch For example for switch 1 port 1 will blink green and the rest of the LEDs will be off On switch 2 port 2 will blink green and the rest of the LEDs will be off The same behavior will be seen with the remaining switches in the stack LED blinks green to show that this is switch 1 in the stack 4 Stack member 1 1 LED blinks green to show that this is swi...

Страница 88: ... information shown by the port LEDs To select or change a mode press the Mode button until the desired mode is highlighted When you change port modes the meanings of the port LED colors also change When you press the Mode button on any switch in the switch stack all the stack switches change to show the same selected mode For example if you press the Mode button on the active switch to show the SP...

Страница 89: ...conds as STP checks the switch for possible loops Amber 10 100 1000 SFP ports SPEED Port is operating at 10 Mb s Off Port is operating at 100 Mb s Green Port is operating at 1000 Mb s Single green flash on for 100 ms off for 1900 ms Uplink ports Port is not operating Off Port is operating at up to 10 Gb s Blinking green Port is operating in half duplex Off DUPLX duplex Port is operating in full du...

Страница 90: ...abling to connect Cisco prestandard IP Phones and wireless access points or IEEE 802 3af compliant devices to PoE ports You must remove from the network any cable or device that causes a PoE fault Caution Blinking amber PoE for the port has been disabled PoE is enabled by default Note Amber 4 Only switches with PoE or PoE ports Beacon LED The UID and the Beacon LED can be turned on by the administ...

Страница 91: ...s LEDs Each port LED is labeled according to its module status For SFP ports a G labeling nomenclature is used where G 1 Gigabit The The G label appears to the left of the uplink port LED For SFP ports a 10G labeling nomenclature is used where 10G 10 Gigabit The 10G label appears to the left of the uplink port LED SFP module ports support both SFP and SFP modules For SFP28 ports a 25G labeling nom...

Страница 92: ... because it has exceeded a limit set in the switch software Link faults occur when non compliant cabling is connected to an SFP SFP port Use only standard compliant cabling to connect to Cisco SFP SFP ports You must remove from the network any cable or device that causes a link fault Caution Blinking amber Link for the SFP SFP SFP28 QSFP has been disabled Amber Cisco Catalyst 9200 Series Switches ...

Страница 93: ...separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Modifications to this product not authorized by Cisco could void the FCC approval and negate your authority to operate the product The Cisco implementation of TCP header compression i...

Страница 94: ......

Отзывы: