Connecting Cables to the Input 10Mhz or 1PPS Interface
Step 1
Connect one end of a mini-coax Y-cable to the GPS unit.
Step 2
Connect one end of the split-side Y-cable mini-coax to the 10Mhz or 1PPS port on the primary RSP of the Cisco ASR
903 Router.
Step 3
Connect the other end of the split-side Y-cable mini-coax to the 10Mhz or 1PPS port on the backup RSP of the Cisco
ASR 903 Router.
Connecting Cables to the Output 10Mhz or 1PPS Interface
Step 1
Connect one end of a mini-coax Y-cable to the Slave unit.
Step 2
Connect one end of the split-side Y-cable mini-coax to the 10Mhz or 1PPS port on the primary RSP of the Cisco ASR
903 Router.
Step 3
Connect the other end of the split-side Y-cable mini-coax to the 10Mhz or 1PPS port on the backup RSP of the Cisco
ASR 903 Router.
Connecting Cables to the ToD Interface
Step 1
Connect one end of a straight-through Ethernet cable to the GPS unit.
Step 2
Connect one end of the split-side Y-cable Ethernet to the ToD port on the primary RSP of the Cisco ASR 903 Router.
Step 3
Connect the other end of the split-side Y-cable Ethernet to the ToD port on the backup RSP of the Cisco ASR 903 Router.
For instructions on how to configure clocking, see the Cisco ASR 903 Router Software Configuration Guide.
Note
To comply with the Telcordia GR-1089 NEBS standard for electromagnetic compatibility and safety, connect
the ToD ports only to intra-building or unexposed wiring or cable. The intrabuilding cable must be shielded
and the shield must be grounded at both ends. The intra-building port(s) of the equipment or subassembly must
not be metallically connected to interfaces that connect to the OSP or its wiring. These interfaces are designed
for use as intra-building interfaces only (Type 2 or Type 4 ports as described in GR-1089-CORE) and require
isolation from the exposed OSP cabling. The addition of Primary Protectors is not sufficient protection in order
to connect these interfaces metallically to OSP wiring.
Warning
For more information about GPS port pinouts, see
Note
Connecting a Cable to the GNSS Antenna Interface
The GNSS module is not hot swappable.
Note
Step 1
Connect one end of a shielded coaxial cable to the GNSS RF IN port.
Cisco ASR 903 and ASR 903U Aggregation Services Router Hardware Installation Guide
117
Installing the Cisco ASR 903 Router
Connecting Cables to the Input 10Mhz or 1PPS Interface
Содержание ASR 903
Страница 2: ... 2015 2018 Cisco Systems Inc All rights reserved ...
Страница 10: ...Cisco ASR 903 and ASR 903U Aggregation Services Router Hardware Installation Guide x Contents ...
Страница 198: ...Cisco ASR 903 and ASR 903U Aggregation Services Router Hardware Installation Guide 188 Troubleshooting Alarm Conditions ...