20
Verify Power Supply Operation
Follow this procedure to verify the power supplies are operating correctly.
Step 1
Check that the power supply LEDs are illuminated as follows:
–
INPUT OK LED is green.
–
FAN OK LED is green.
–
OUTPUT FAILED LED is not illuminated.
Step 2
To ensure that the power supply is running, enter the
show platform
command. This output sample is from a
Cisco ASR 1002-F Router.
#show platform
Chassis type: ASR1002-F
The following is a sample output display:
Note
If the LEDs indicate a power problem or the power supply state shows “ps,fail”, then contact a customer service
representative for assistance or additional instructions.
Start the Cisco ASR 1002-F Router
Check the following conditions before you start the Cisco ASR 1002-F Router:
•
The Cisco ASR 1002-F Router has one slot for the Cisco ASR1002-SIP10-F. Make certain that the SPA is firmly seated in
its subslot and its captive installation screws are securely tightened.
Note
The ASR 1002-F Router has only one half-height removable SPA.
•
The integrated Cisco ASR1002-ESP-F forwarding processor in the Cisco ASR 1002-F Router is secured and its captive
screws are securely tightened.
•
All network interface cables are connected.
•
The console terminal is turned on.
Slot
Type
State
Insert Time
1
ASR1000-SIP10 ok
00:03:19
1/1
SPA-8X1GE-V2
ok
00:02:23
2
ASR1000-SIP10
ok
00:03:19
2/0
SPA-1X10GE-L-V2
ok
00:02:22
2/1
SPA-8X1GE-V2 ok
00:02:17
R0
ASR1000-RP1
ok,active
00:03:19
F0
ASR1000-ESP10
ok,active
00:03:19
P0
ASR1002-PWR-AC
ok
00:02:50
P1
ASR1002-PWR-AC
ps, fail
00:02:50
Slot
CPLD Version
Firmware
Version
1
07091401
12.2(33r)XN2
2
07091401
12.2(33r)XN2
R0
08060301
12.2(0:0)
F0
08041102
12.2(33r)XN2