Table 10: Physical Specifications
Specification
Description
41 to 95°F (5 to 35°C)
Derate the maximum temperature by 1°C per every 305 meters of altitude above
sea level.
Temperature, Operating
–40 to 149°F (–40 to 65°C)
Temperature, non-operating
(when the server is stored or transported)
10 to 90%
Humidity (RH), operating
5 to 93%
Humidity (RH), non-operating
(when the server is stored or transported)
0 to 10,000 feet
Altitude, operating
0 to 40,000 feet
Altitude, non-operating
(when the server is stored or transported)
5.5
Sound power level
Measure A-weighted per ISO7779 LwAd (Bels)
Operation at 73°F (23°C)
40
Sound pressure level
Measure A-weighted per ISO7779 LpAm (dBA)
Operation at 73°F (23°C)
Power Specifications
Do not mix power supply types or wattages in the server. Both power supplies must be identical.
Note
You can get more specific power information for your exact server configuration by using the Cisco UCS
Power Calculator:
The power specifications for the supported power supply options are listed in the following sections.
770 W AC Power Supply
This section lists the specifications for each 770 W AC power supply (Cisco part number APIC-PSU1-770W).
Cisco APIC M3/L3 Server Installation and Service Guide
94
Server Specifications
Power Specifications