C-5
Firepower 8000 Series Hardware Installation Guide
Appendix C Installing a Malware Storage Pack
Installation
Step 5
Turn on the system.
Refer to <Blue>Post Installation on page 11 for information on restarting a device after a malware
storage pack has been installed.
Installing a Malware Storage Pack on a Version 6.0.1 Device
Use the following procedure to install a malware storage pack in a device already configured and running
Firepower System version 5.3 or greater.
To install malware storage pack in a device running version 5.3 or greater:
Step 1
Shut down the system.
Step 2
Power off the device.
Step 3
Install the malware storage pack:
•
For 81xx Family devices, refer to <Blue>Instructions for the 81xx Family Devices on page 5.
•
For 82xx Family and 83xx Family devices, refer to <Blue>Instructions for the 82xx Family and 83xx
Family Devices on page 8.
Step 4
Turn on the system.
•
Refer to <Blue>Post Installation on page 11 for information on restarting a device after a second
SSD has been installed.
Instructions for the 81xx Family Devices
The following section describes how to install a malware storage pack in the 81xx Family of devices,
which includes the Firepower 8120, 8130, and 8140 devices. Note that the malware storage pack is
not
supported on the AMP8150 device.
81xx Family Chassis Front View
The SSD trays are located on the front of the 81xx Family chassis.
Figure C-1
81xx Family (Chassis: CHAS-1U-AC/DC) Front View