53
Cisco Aironet 1520 Series Outdoor Mesh Access Point Mounting Instructions
78-18269-04
Powering the Access Point
Step 4
Loosen the round end of the liquid tight adapter by turning counterclockwise, but do not remove (see
Figure 34
).
Figure 34
Liquid Tight Adapter
Note
The liquid tight adapter accepts a cable diameter of 0.20 to 0.35 in. (0.51 to 0.89 cm).
Step 5
Insert a bare end of the DC power cable into the rounded end of the liquid tight adapter (see
Figure 34
),
and pull approximately 6 inches of cable through the adapter.
Step 6
Strip the DC cable jacket back about 1 inch to expose the wires and strip the insulation about 3/8 in. (9.5
mm) from each wire.
1
Thread end
2
Round end