Cisco Aironet 1520 Series Outdoor Mesh Access Point Mounting Instructions
78-18269-04
Powering the Access Point
If your access point contains a backup battery pack, you must press the reset button for 10 seconds or
more (see the
“Disabling Backup Battery Power” section on page 39
.)
Step 3
When using the streetlight power tap adapter (AIR-PWR-ST-LT-R3P=), ensure that the access point is
mounted within 3 ft (1 m) of the outdoor light control. For mounting instructions, refer to the
“Mounting
the Access Point on a Pole” section on page 21
.
Step 4
Ensure a 6-AWG ground wire is attached to the access point (see
Figure 31
) and connected to the
streetlight pole (for instructions see
Grounding the Access Point, page 39
).
Figure 31
Using the Streetlight Power Tap Adapter
Step 5
Refer to
Figure 31
. The streetlight power tap adapter uses a 3-pronged LC-10 twist-lock adapter that is
placed between the outdoor light control and its fixture. The LC-10 twist-lock adapter is designed to be
used with LC-10 listed outdoor light controls operating at 100 to 480 VAC, 50 to 60 Hz.
Step 6
Disconnect the outdoor light control from its fixture.
Step 7
Verify that the voltage available at the fixture is between 100 and 480 VAC, 50 to 60 Hz.
Step 8
Turn off power to the fixture at the designated circuits.
Caution
When installing the streetlight power tap adapter to the access point AC power connector, always
connect the access point end of the cable FIRST. When removing the streetlight power tap adapter,
always disconnect the access point end of the cable
last
.
Note
Ensure that your antennas are connected to the access point before you apply power to the access
point.
1
Outdoor light control
3
6-AWG copper grounding wire
2
Streetlight power tap adapter
231524
1
2
3