Cisco Aironet 1520 Series Outdoor Mesh Access Point Mounting Instructions
78-18269-04
Mounting the Access Point
Closing the Access Point Hinged Cover
To close the access point cover, follow these steps:
Step 1
When closing the access point cover, be careful not to pinch internal wires.
Step 2
Carefully position the cover flush with all sides of the access point, then slowly hand-tighten each bolt.
Step 3
When all bolts are hand-tightened, use a 13 mm closed-end wrench or socket to partially tighten the bolts
in the tightening sequence shown in
Figure 24
. Tighten each bolt to 3 to 4 ft lbs (0.34 to 0.45 Nm).
Step 4
Repeat
Step 3
using the same tightening sequence to fully tighten each bolt to 6 to 7 ft lbs
(0.68 to 0.79 Nm).
Figure 24
Hinged Cover Bolt Tightening Sequence