Chapter 3 Troubleshooting
3-2
Cisco RPS 675 Redundant Power System Hardware Installation Guide
78-15201-03
Fan (blower)
LED is amber.
The blower is not
operating properly.
The fan is defective. Replace the
RPS 675.
One or more DC
Output LEDs are
blinking green.
The RPS is
unavailable to the
connected device. It
is either providing
power to another
connected device or a
fault condition exists.
Verify that the RPS is supplying
power to one device. If so, this is a
normal indication and will change
when that external device is again
supplying its own power and you
press the Standby/Active button.
One or more DC
Output LEDs are
solid amber.
The RPS is in standby
mode.
Press the
Standby/Active
button to
put the RPS into active (or ready)
mode.
Table 3-1
LED Indications and Appropriate Action (continued)
Symptom
Condition
Action