Cisco 6130 NI-1 to NI-2 Upgrade Kit Conversion Procedures
78-10709-03
Cisco 6130 NI-1 to NI-2 Conversion Procedures
Connect the Software Management System to the NI-2 Card
Connect both the 10BaseT RJ-45 port on the NI-2 card (ENET) and the Sun SPARCstation running
the CDM management application to an Ethernet so that the Cisco 6130 and the management station
can communicate.
Warning
The ports labeled "ENET," "CNSL," and "AUX" are safety extra-low voltage (SELV)
circuits. SELV circuits should be connected only to other SELV circuits. Because the DSL
circuits are treated like telephone-network voltage, avoid connecting the SELV circuit
to the telephone network voltage (TNV) circuits.
Timesaver
Cisco recommends that you label each data cable at both ends to identify its destination.
Connect a Console Terminal
Connect a VT100-compatible terminal to the system console port on the NI-2 card (CNSL). Connect
the terminal to a power source and set it up using the values that are shown in Table 7.
Warning
The ports labeled "ENET," "CNSL," and "AUX" are SELV circuits. SELV circuits should be
connected only to other SELV circuits. Because the DSL circuits are treated like
telephone-network voltage, avoid connecting the SELV circuit to the TNV circuits.
Connect the Auxiliary Port
Note
This step is optional.
Connect a terminal, a modem, or another serial device to the RJ-45 auxiliary port on the NI-2
card (AUX).
Warning
The ports labeled "ENET," "CNSL," and "AUX" are SELV circuits. SELV circuits should be
connected only to other SELV circuits. Because the DSL circuits are treated like
telephone-network voltage, avoid connecting the SELV circuit to the TNV circuits.
Table 7
Terminal Settings
Baud rate
9600 (transmit and receive)
Character size
8 bits
Parity
None
Stop bits
1
Xon/Xoff
Hardware busy