36
Cisco 6130 NI-1 to NI-2 Upgrade Kit Conversion Procedures
78-10709-03
Cisco 6130 NI-1 to NI-2 Conversion Procedures
Step 9
Use a Phillips-head screwdriver and three backplane screws to attach the safety shield to the left side
of the system I/O card, as shown in Figure 16. The backplane screws will screw into the existing
standoff screws on the backplane.
Figure 16
Safety Shield and ESD Shield Installation
Step 10
Use a one-quarter inch socket driver or wrench to screw a standoff screw between relays K4 and K5, as
shown in Figure 16. Tighten the standoff screws using the one-quarter inch socket driver or wrench.
Step 11
Place the ESD shield above the standoff screw that you installed in Step 10 so that the hole in the
shield aligns with the standoff screw, as shown in Figure 16.
Step 12
Use a Phillips-head screwdriver and three backplane screws to attach the plastic ESD shield to the
system I/O card (see Figure 16).
J39
42678
J48
J45
P13
P14
P17
P15
System I/O
card
ESD
shield
P18
U1
Standoff
screw
Component
safety shield