background image

Corporate Headquarters
Cisco Systems, Inc.
170 West Tasman Drive
San Jose, CA 95134-1706
USA
http://www.cisco.com
Tel: 408 526-4000

800 553-NETS (6387)

Fax: 408 526-4100

European Headquarters
Cisco Systems Europe s.a.r.l.
Parc Evolic, Batiment L1/L2
16 Avenue du Quebec
Villebon, BP 706
91961 Courtaboeuf Cedex
France
http://www-europe.cisco.com
Tel: 33 1 6918 61 00
Fax: 33 1 6928 83 26

Americas
Headquarters
Cisco Systems, Inc.
170 West Tasman Drive
San Jose, CA 95134-1706
USA
http://www.cisco.com
Tel: 408 526-7660
Fax: 408 527-0883

Asia Headquarters
Nihon Cisco Systems K.K.
Fuji Building, 9th Floor
3-2-3 Marunouchi
Chiyoda-ku, Tokyo 100
Japan
http://www.cisco.com
Tel:

81 3 5219 6250

Fax: 81 3 5219 6001

Cisco Systems has more than 200 offices in the following countries. Addresses, phone numbers, and fax numbers are listed on the

C i s c o   C o n n e c t i o n   O n l i n e   W e b   s i t e   a t   h t t p : / / w w w . c i s c o . c o m .

Argentina 

 Australia 

 Austria 

 Belgium 

 Brazil 

 Canada 

 Chile 

 China (PRC) 

 Colombia 

 Costa Rica 

 Czech Republic 

 Denmark

England 

 France 

 Germany 

 Greece 

 Hungary 

 India 

 Indonesia 

 Ireland 

 Israel 

 Italy 

 Japan 

 Korea 

 Luxembourg 

 Malaysia

Mexico 

 The Netherlands 

 New Zealand 

 Norway 

 Peru 

 Philippines 

 Poland 

 Portugal 

 Russia 

 Saudi Arabia 

 Scotland 

 Singapore

South Africa 

 Spain  

 Sweden  

 Switzerland  

 Taiwan, ROC 

 Thailand  

 Turkey  

  United Arab Emirates  

 United States  

 Venezuela

Copyright © 1998 Cisco Systems, Inc. All rights reserved. AccessPath, AtmDirector, the CCIE logo, CD-PAC, Centri, Centri Bronze, Centri Gold, Centri Security Manager, Centri Silver, the
Cisco Capital logo, Cisco IOS, the Cisco IOS logo, CiscoLink, the Cisco Powered Network logo, the Cisco Press logo, ClickStart, ControlStream, Fast Step, FragmentFree, IGX, JumpStart, Kernel Proxy,
LAN

2

LAN Enterprise, LAN

2

LAN Remote Office, MICA, Natural Network Viewer, NetBeyond, Netsys Technologies, Packet, PIX, Point and Click Internetworking, Policy Builder, RouteStream, Secure

Script, SMARTnet, StrataSphere, StrataSphere BILLder, StrataSphere Connection Manager, StrataSphere Modeler, StrataSphere Optimizer, Stratm, StreamView, SwitchProbe, The Cell, TrafficDirector,
VirtualStream, VlanDirector, Workgroup Director, Workgroup Stack, and XCI are trademarks; Empowering the Internet Generation and The Network Works. No Excuses. are service marks; and BPX,
Catalyst, Cisco, Cisco Systems, the Cisco Systems logo, EtherChannel, FastHub, FastPacket, ForeSight, IPX, LightStream, OptiClass, Phase/IP, StrataCom, and StrataView Plus are registered trademarks
of Cisco Systems, Inc. in the U.S. and certain other countries. All other trademarks mentioned in this document are the property of their respective owners. 9801R

Printed in the USA on recycled paper containing 10% postconsumer waste.

78-5596-01

Содержание 5509 - Catalyst Chassis Switch

Страница 1: ...ch Load PCMCIA EJECT 0 100 10 100Mbps LINK CONSOLE AUX PORT 1 RE SE T FA N SL OT 1 SL OT 0 AC TIV E PS 1 PS 2 SUPERVISOR ENGINE I I I 10 100 FAST ETHERCHANNEL MDIX MDIX WS U5531 FETX WS x5530 10 100Mbps LINK SY ST EM ST AT US 1 2 3 4 5 6 7 8 9 10 11 12 ST ATU S FAST ETHERNET SWITCHING MODULE 1 2 3 4 5 6 7 8 9 10 11 12 ST ATU S 1 2 3 4 5 6 7 8 9 10 11 12 ST ATU S 1 2 3 4 5 6 7 8 9 10 11 12 ST ATU S...

Страница 2: ...nt racks Ensure the environment is within specification Prepare network connections 3 Obtain the following equipment ESD grounding strap and antistatic mat Numbers 1 and 2 Phillips screwdrivers and 3 16 inch flat blade screwdriver Tape measure and level 4 Ensure your safety when installing the Catalyst 5509 switch Lift the chassis safely Cooperate with the natural laws of electricity Ensure that t...

Страница 3: ... RE SE T FA N SL OT 1 SL OT 0 AC TIV E PS 1 PS 2 SUPERVISOR ENGINE I I I 10 100 FAST ETHERCHANNEL MDIX MDIX WS U5531 FETX WS x5530 10 100Mbps LINK SY ST EM ST AT US PORT 2 Switch Load PCMCIA EJECT 0 100 10 100Mbps LINK CONSOLE AUX PORT 1 RE SE T FA N SL OT 1 SL OT 0 AC TIV E PS 1 PS 2 SUPERVISOR ENGINE I I I 10 100 FAST ETHERCHANNEL MDIX MDIX WS U5531 FETX WS x5530 10 100Mbps LINK SY ST EM ST AT U...

Страница 4: ...DULE FAST ETHERNET SWITCHING MODULE 1 2 3 4 5 6 7 8 9 10 11 12 ST AT US FAST ETHERNET SWITCHING MODULE FAST ETHERNET SWITCHING MODULE L bracket AC OK FAN OK OUTPUT FAIL o AC OK FAN OK OUTPUT FAIL o PORT 2 Switch Load PCMCIA EJECT 0 100 10 100Mbps LINK CONSOLE AUX PORT 1 RE SE T FA N SL OT 1 SL OT 0 AC TIV E PS 1 PS 2 SUPERVISOR ENGINE I I I 10 100 FAST ETHERCHANNEL MDIX MDIX WS U5531 FETX WS x5530...

Страница 5: ... DTE DB 25 straight through cable into the console port Supervisor Engine III To connect a terminal to the Supervisor Engine III console port plug an RJ 45 to RJ 45 straight through cable into the console port jack Use an RJ 45 to DB 25 or RJ 45 to DB 9 adapter to connect to the terminal Caution To prevent ESD damage to electronic components always use an ESD wrist strap when handling modules or c...

Страница 6: ...000 Series Module Installation Guide RJ 45 To connect to modules with RJ 45 interfaces use Category 5 UTP 100BaseTX 10 100BaseTX CDDI Token Ring ATM Category 3 UTP 10BaseT or Type 1 STP Token Ring cables with male RJ 45 interfaces Media Independent Interface MII Supervisor Engine I and II modules with 100BaseTX uplinks have MII ports in addition to RJ 45 ports To connect to the MII interfaces use ...

Страница 7: ...nnectors SC Type Fiber Optic To connect to modules with SC type fiber optic interfaces use single mode or multimode fiber optic cable with male SC type connectors ST Type Fiber Optic To connect to modules with ST type fiber optic interfaces use single mode FDDI or multimode 10BaseFL fiber optic cable with male ST type connectors 3 ACTIVE LINK P O R T A U N I 1 5 5 S M TX RX TX RX 2 LINK ...

Страница 8: ...t the Switch to the Network continued MIC Type Fiber Optic To connect to the FDDI module MMF WS X5101 use multimode fiber optic cable with a male MIC type connector BNC To connect to the ATM dual PHY DS3 module WS X5166 use 75 ohm RG 59 coaxial cable with male BNC connectors 3 ...

Страница 9: ...able to a grounded outlet If possible connect each cable to an outlet on a separate circuit Make sure that the source power is within range Warning Before you work on any equipment be aware of the hazards involved with electrical circuitry and be familiar with standard practices for preventing accidents Caution To prevent ESD damage to electronic components always use an ESD wrist strap when handl...

Страница 10: ...P 322985 or 52941 suggested DC input wires are 10 AWG copper conductors 4 Wire the DC input power supply to the terminal block see figure ensuring that all wire connections are secure a Connect the ground wire to the ground terminal you should always connect the ground wire first and disconnect it last b Connect the 48V wire to the terminal c Connect the 48V return to the terminal Warning Before p...

Страница 11: ...o 12 AWG copper conductor ground wire to the CO ground connector Use a ground wire lug that is 0 320 of an inch 7 8 mm or less 8 Restore power to the DC input circuit by turning the circuit breaker ON DC OK OK FAN OUTPUT FAIL o DC OK OK FAN OUTPUT FAIL o PS 1 PS 2 FA N LINK SL OT 2 SL OT 1 PC MCIA EJ EC T AU X CONSO LE En et RX TX RES ET SWITCH PROCESSOR UTP CO ground connector location under lip ...

Страница 12: ...hould hear the system fans operating The System Status LED on the supervisor engine should be green after the boot is complete it will flash red orange and green during startup The supervisor engine interface LEDs and module LEDs such as the Link LEDs might blink or stay lit continuously during the boot process Many module LEDs do not come on until you configure the interfaces Wait until the syste...

Страница 13: ...static bag Caution To prevent ESD damage to electronic components always use an ESD wrist strap when handling modules or coming into contact with internal components 1 2 3 4 5 6 7 8 9 10 11 12 ST ATU S 1 2 3 4 5 6 7 8 9 10 11 12 ST ATU S SUPERVISOR ENGINE SY ST EM ST AT US FA N AC TIV E MD I X MI I MD I X MI I RE SE T CO NS OL E 10 0 1 SW ITC H LO G PS 2 10 0 Mb ps LIN K 10 0 Mb ps LIN K PO RT 1 P...

Страница 14: ...event ESD damage to electronic components always use an ESD wrist strap when handling modules or coming into contact with internal components AC OK FAN OK OUTPUT FAIL o TX TX RX 0 DS 3 RX TX RX TX RX 1 DS 3 DS3 TX TX RX 0 DS 3 RX TX RX TX RX 1 DS 3 DS3 PS 1 PS 2 FA N LIN K SL OT 2 SL OT 1 PC MC IA EJ EC T AU X CO NS OL E En et RX TX RE SE T SWITCH PROCESSOR TX UT P3 UT P3 UT P3 UT P3 RX UTP TX RX ...

Страница 15: ...ck cover from the power supply Disconnect the DC input wires from the terminal block Disconnect the ground wire last 4 Disconnect the central office CO ground from the CO ground connector 5 Use a flat blade screwdriver to loosen the captive screw on the power supply 6 Grasp the power supply handle and pull the supply straight out of the bay supporting the supply with your other hand see figure Ins...

Страница 16: ... South Africa Spain Sweden Switzerland Taiwan ROC Thailand Turkey United Arab Emirates United States Venezuela Copyright 1998 Cisco Systems Inc All rights reserved AccessPath AtmDirector the CCIE logo CD PAC Centri Centri Bronze Centri Gold Centri Security Manager Centri Silver the Cisco Capital logo Cisco IOS the Cisco IOS logo CiscoLink the Cisco Powered Network logo the Cisco Press logo ClickSt...

Отзывы: