12-8
Catalyst 4500 Series, Catalyst 2948G, Catalyst 2948G-GE-TX, and Catalyst 2980G Switches Software Configuration Guide—Release 8.2GLX
78-15908-01
Chapter 12 Configuring Dynamic VLAN Membership with VMPS
Configuring VMPS
This example shows how to specify the primary VMPS server and two backup VMPS servers, and verify
the VMPS server specification:
Console> (enable) set vmps server 192.0.0.1 primary
192.0.0.1 added to VMPS table as primary domain server.
Console> (enable) set vmps server 192.0.0.6
192.0.0.6 added to VMPS table as backup domain server.
Console> (enable) set vmps server 192.0.0.9
192.0.0.9 added to VMPS table as backup domain server.
Console> (enable) show vmps server
VMPS Client Status:
---------------------
VMPS VQP Version: 1
Reconfirm Interval: 60 min
Server Retry Count: 3
VMPS domain server: 192.0.0.1 (primary)
192.0.0.6
192.0.0.9
This example shows how to set ports 1 to 3 on module 3 to dynamic mode, disable trunking port 1 on
module 2 to make it a dynamic port, and verify the port configuration:
Console> (enable) set port membership 3/1-3 dynamic
Ports 3/1-3 vlan assignment set to dynamic.
Console> (enable) set port membership 2/1 dynamic
Spantree port fast start option enabled for ports 2/1.
Trunk mode set to off for ports 2/1.
Console> show port
Port
Name
Status
Vlan
Level
Duplex
Speed
Type
1/1
connect
trunk
normal
full
100
100 BASE-TX
1/2
connect
trunk
normal
half
100
100 BASE-TX
2/1
connect
dyn
normal
full
155
OC3 MMF ATM
3/1
connect
dyn-5
normal
half
10
10 BASE-T
3/2
connect
dyn-5
normal
half
10
10 BASE-T
3/3
connect
dyn-5
normal
half
10
10 BASE-T
.
.
.
Console> (enable)
Note
The show port command displays dyn- in the Vlan column of the display when a VLAN has not been
assigned to a port.