background image

 

 

Data Sheet 

© 2009 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. 

Page 13 of 20 

Power Connectors 

  Customers can provide power to a switch by using either the internal power supply or the Cisco RPS 2300. The 

connectors are located at the back of the switch. 
Internal-Power-Supply Connector 

  The internal power supply is an autoranging unit. 

  The internal power supply supports input voltages between 100 and 240 VAC. 

  Use the supplied AC power cord to connect the AC power connector to an AC power outlet. 

  Cisco RPS Connector 

  The connector offers connection for an optional Cisco RPS 2300 (model PWR-RPS2300) that uses AC input and 

supplies DC output to the switch. 

Indicators 

  Per-port status LEDs: Link integrity, disabled, activity, speed, full-duplex indications, PoE applied, PoE error, and 

PoE disabled indications 

  System-status LEDs: System, RPS, link status, link duplex, link speed, and PoE indications 

 

Inches 

Centimeters 

3560V2-24TS 

1.73 x 17.46x 11.62 

 4.4 x 44.3 x 29.5 

3560V2-48TS 

1.73 x 17.46x 11.62 

 4.4 x 44.3 x 29.5 

3560V2-24PS 

1.73 x 17.46x 11.62 

 4.4 x 44.3 x 29.5 

3560V2-48PS 

1.73 x 17.46x 11.62 

 4.4 x 44.3 x 29.5 

Dimensions 
(H x W x D) 

3560V2-24DC 

1.73 x 17.46x 11.62 

 4.4 x 44.3 x 29.5 

 

Pounds 

Kilograms 

3560V2-24TS 

8.2 

3.7 

3560V2-48TS 

3560V2-24PS 

10 

4.6 

3560V2-48PS 

11 

Weight 

3560V2-24DC 

3.7 

 

Fahrenheit 

Centigrade 

Operating temperature 

32 to 113ºF 

0 to 45ºC 

Storage temperature 

-13 to 158ºF 

-25 to 70ºC 

 

Feet 

Meters 

Operating altitude 

Up to 9,843 ft 

Up to 3,000 m 

Storage altitude 

Up to 15,000 ft 

Up to 4,573 m 

 

 

 

Operating relative humidity 

10 to 85% noncondensing 

Environmental Ranges 

Storage relative humidity 

10 to 85% noncondensing 

ISO 7779 & ISO 9296: Bystander positions operating to an ambient temperature of 25°C 

 

Sound Pressure 

Sound Power 

 

LpA 

(Typical) 

LpAD 

(Maximum) 

LwA 

(Typical) 

LwAD 

(Maximum) 

3560V2-24TS 

41 dB 

44 dB 

5.1 B 

5.4 B 

3560V2-48TS 

42 dB 

45 dB 

5.2 B 

5.5 B 

3560V2-24PS 

44 dB 

47 dB 

5.5 B 

5.7 B 

3560V2-48PS 

45 dB 

48 dB 

5.5 B 

5.8 B 

3560V2-24DC 

41 dB 

44 dB 

5.2 B 

5.5 B 

Acoustic Noise 

Typical: Noise emission for a typical configuration and load at 25° C 

Maximum: Statistical maximum to account for variation in production 

3560V2-24TS 

377,260 hours 

3560V2-48TS 

301,886 hours 

3560V2-24PS 

275,360 hours 

3560V2-48PS 

206,041 hours 

Mean Time Between 
Failure (MTBF) 

3560V2-24DC 

451,606 hours 

Содержание 3560V2 - Catalyst 48 10/100 Poe

Страница 1: ...r switch for enterprise retail and branch office environments as it maximizes productivity and investment protection by enabling a unified network for data voice and video Figure 1 Cisco Catalyst 3560 v2 Switches Cisco Catalyst 3560 v2 Series Highlights Lower power consumption than its predecessors Backward compatible uses the same Cisco IOS Software image as the 3560 series and has the same featu...

Страница 2: ...nt time and cost The Cisco IOS Software release to be preloaded can be selected from a list of supported Cisco IOS Software releases including the crypto version Cisco EnergyWise The Cisco Catalyst 3560 v2 series support Cisco EnergyWise which is a technology that enables monitoring reporting and management of energy consumption by end devices that are Cisco EnergyWise enabled This technology enab...

Страница 3: ...t Cable Primary Features and Benefits Ease of Use and Deployment The Cisco Catalyst 3560 v2 series offers several ease of use features which enable fast and easy configuration of advanced Cisco Catalyst capabilities These features include Cisco SmartPorts simplify the configuration of advanced Cisco Catalyst capabilities encapsulating years of Cisco networking expertise Cisco SmartPort macros offe...

Страница 4: ... transmission mode to optimize bandwidth Dynamic Trunking Protocol DTP helps enable dynamic trunk configuration across all switch ports Port Aggregation Protocol PAgP automates the creation of Cisco Fast EtherChannel groups or Gigabit EtherChannel groups to link to another switch router or server Link Aggregation Control Protocol LACP allows the creation of Ethernet channeling with devices that co...

Страница 5: ...determine the order of authentication methods on the network For example if the order is set to 802 1x MAB and WebAuth the network will first try to authenticate via 802 1x then via MAB and then via WebAuth Multi Authentication or MultiAuth enables up to 8 users to authenticate via the same switch port This feature includes support for multiple authentication methods such as 802 1x MAB and WebAuth...

Страница 6: ...her user s IP address by creating a binding table between the client s IP and MAC address port and VLAN DHCP Interface Tracker Option 82 augments a host IP address request with the switch port ID Port security secures the access to an access or trunk port based on MAC address After a specific timeframe the aging feature removes the MAC address from the switch to allow another device to connect to ...

Страница 7: ... interface goes down the peer interface will carry all the traffic for all VLANs Command switch redundancy enabled in Cisco Network Assistant software allows designation of a backup command switch that takes over cluster management functions if the primary command switch fails Unidirectional Link Detection Protocol UDLD and Aggressive UDLD allow unidirectional links to be detected and disabled to ...

Страница 8: ...nnects two multicast enabled networks across nonmulticast networks The IP Services license is required Fallback bridging forwards non IP traffic between two or more VLANs The IP Services license is required Integrated Cisco IOS Software Features for Bandwidth Optimization The Cisco Catalyst 3560 v2 series offers several advanced features for bandwidth optimization These features include Per port b...

Страница 9: ...ies offers superior multilayer granular QoS features to help ensure that network traffic is classified and prioritized and that congestion is avoided in the best possible manner Configuration of QoS is greatly simplified through automatic QoS Auto QoS a feature that detects Cisco IP phones and automatically configures the switch for the appropriate classification and egress queuing Other QoS featu...

Страница 10: ...ommon user interface and command set with all Cisco routers and Cisco Catalyst desktop switches Cisco Discovery Protocol version 2 allows the Cisco Catalyst 3560 v2 Series Switch to negotiate a more granular power setting when connecting to a Cisco powered device such as IP phones or access points than what is provided by IEEE classification The PoE MIB provides proactive visibility into power usa...

Страница 11: ...dows based application that simplifies the administration of networks of up to 250 users It supports a wide range of Cisco Catalyst intelligent switches from Cisco Catalyst 2960 through Cisco Catalyst 4506 With Cisco Network Assistant users can manage Cisco Catalyst switches plus launch the device managers of Cisco integrated services routers ISRs and Cisco Aironet WLAN access points The easy to u...

Страница 12: ... MTU Up to 9000 bytes Jumbo frames 9016 bytes MAC routing security and QoS scalability numbers depend on the type of template used in the switch Default Template Access Template VLAN Template Routing Template MAC address 6K 4K 12K 3K IGMP groups and multicast routes 1K 1K 1K 1K Total unicast routes 8K 6K 0 11K Directly connected hosts 6K 4K 0 3K Indirect routes 2K 2K 0 8K Security ACEs 1K 2K 1K 1K...

Страница 13: ... 17 46x 11 62 4 4 x 44 3 x 29 5 3560V2 48PS 1 73 x 17 46x 11 62 4 4 x 44 3 x 29 5 Dimensions H x W x D 3560V2 24DC 1 73 x 17 46x 11 62 4 4 x 44 3 x 29 5 Pounds Kilograms 3560V2 24TS 8 2 3 7 3560V2 48TS 9 4 3560V2 24PS 10 4 6 3560V2 48PS 11 5 Weight 3560V2 24DC 8 3 7 Fahrenheit Centigrade Operating temperature 32 to 113ºF 0 to 45ºC Storage temperature 13 to 158ºF 25 to 70ºC Feet Meters Operating al...

Страница 14: ...ughput Power Consumption 3560V2 24TS SD 22W 75 BTU hour Switch Power Consumption PoE Power Total Output BTU 3560V2 24PS 435W 370W 220 BTU hour Measured 100 Throughput Power Consumption with maximum possible PoE loads 3560V2 48PS 452W 370W 280 BTU hour Switch Power Consumption PoE Power Total Output BTU 3560V2 24PS 238W 185W 181 BTU hour Measured 5 Throughput Power Consumption with 50 PoE loads 356...

Страница 15: ...S MIB OSPF MIB RFC 1253 PIM MIB RFC1213 MIB RFC1253 MIB RMON MIB RMON2 MIB SNMP FRAMEWORK MIB SNMP MPD MIB SNMP NOTIFICATION MIB SNMP TARGET MIB SNMPv2 MIB TCP MIB UDP MIB Standards IEEE 802 1s IEEE 802 1w IEEE 802 1x IEEE 802 3ad IEEE 802 3af IEEE 802 3x full duplex on 10BASE T 100BASE TX and 1000BASE T ports IEEE 802 1D Spanning Tree Protocol IEEE 802 1p CoS Prioritization IEEE 802 1Q VLAN IEEE ...

Страница 16: ... RMA request Actual delivery times may vary depending on Customer location Cisco reserves the right to refund the purchase price as its exclusive warranty remedy To Receive a Return Materials Authorization RMA Number Please contact the party from whom you purchased the product If you purchased the product directly from Cisco contact your Cisco Sales and Service Representative Complete the form bel...

Страница 17: ...Series switches Table 7 Ordering Information for Cisco Catalyst 3560 v2 Series Switches Part Numbers Description WS C3560V2 24TS S 24 Ethernet 10 100 ports and 2 SFP based Gigabit Ethernet ports 1RU fixed configuration multilayer switch IPv6 IP Base software feature set WS C3560V2 24TS SD 24 Ethernet 10 100 ports and 2 SFP based Gigabit Ethernet ports 1RU fixed configuration multilayer switch IPv6...

Страница 18: ...00 and Cisco Catalyst 3560 E 3750 E series switches Spare rack mount kits for the Cisco Catalyst 3560 v2 Series RCKMNT 1RU Spare rack mount kit for the Cisco Catalyst 3560 and 3750 series RCKMNT REC 1RU 1RU recessed rack mount kit for the Cisco Catalyst 3560 and 3750 series Spare power cords for the Cisco Catalyst 3560 v2 Series CAB AC Standard power cord 125V 10A 2 1 meters CAB 16AWG AC Standard ...

Страница 19: ...ernet and 1G 2G FC orange CWDM SFP 1590 Cisco CWDM SFP 1590 nm Gigabit Ethernet and 1G 2G FC red CWDM SFP 1610 Cisco CWDM SFP 1610 nm Gigabit Ethernet and 1G 2G FC brown DWDM SFP 3033 DWDM SFP 1530 33 nm SFP 100 GHz ITU grid DWDM SFP 3112 DWDM SFP 1531 12 nm SFP 100 GHz ITU grid DWDM SFP 3190 DWDM SFP 1531 90 nm SFP 100 GHz ITU grid DWDM SFP 3268 DWDM SFP 1532 68 nm SFP 100 GHz ITU grid DWDM SFP 3...

Страница 20: ...Data Sheet 2009 Cisco Systems Inc All rights reserved This document is Cisco Public Information Page 20 of 20 Printed in USA C78 530976 01 08 09 ...

Отзывы: