background image

 

 

Data Sheet 

© 2009 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. 

Page 6 of 14 

Intelligent Layer 2 Availability and Scalability 

The Cisco Catalyst 2960 LAN Lite Series is equipped with a robust set of features that allow for network scalability 

and higher availability with a complete suite of Layer 2 protocols including Spanning Tree Protocol enhancements 

aimed maximizing availability in a Layer 2 network. 

Enhancements to the standard Spanning Tree Protocol, such as Per-VLAN Spanning Tree Plus (PVST+), Uplink 

Fast, and PortFast, maximize network uptime. PVST+ allows for Layer 2 load sharing on redundant links to efficiently 

use the extra capacity inherent in a redundant design. Uplink Fast, PortFast, and BackboneFast all greatly reduce 

the standard 30- to 60-second Spanning Tree Protocol convergence time. Loop guard and bridge-protocol-data-unit 

(BPDU) guard provide Spanning Tree Protocol loop avoidance.  

Superior redundancy features include: 

 

Up to 64 VLANs per switch and up to 64 spanning-tree instances per switch are supported. 

 

Cisco Uplink Fast and BackboneFast technologies help ensure quick failover recovery, enhancing overall 

network stability and reliability. 

 

Per-VLAN Rapid Spanning Tree Plus (PVRST+) allows rapid spanning-tree reconvergence on a per-VLAN 

spanning-tree basis, without requiring the implementation of spanning-tree instances. 

 

IEEE 802.1d Spanning Tree Protocol support for redundant backbone connections and loop-free networks 

simplifies network configuration and improves fault tolerance.  

 

IEEE 802.1s Multiple Spanning Tree Protocol (MSTP) allows a spanning-tree instance per VLAN, enabling 

Layer 2 load sharing on redundant links. 

 

IEEE 802.1w Rapid Spanning Tree Protocol (RSTP) provides rapid spanning-tree convergence 

independent of spanning-tree timers and the benefit of distributed processing. 

 

Cisco EtherChannel bandwidth aggregation enhances fault tolerance and offers higher-speed aggregated 

bandwidth . 

 

Unidirectional Link Detection Protocol (UDLD) and Aggressive UDLD allow unidirectional links to be 

detected and disabled to avoid problems such as spanning-tree loops. 

 

Switch port autorecovery (errdisable) automatically attempts to reenable a link that is disabled because of 

a network error. 

The following tables starting with Table 2 provide both hardware and software details about the Cisco Catalyst 2960 

LAN Lite Switches. 

Table 2. 

Catalyst 2960 LAN Lite Series Switch Hardware 

Description 

Specification 

Forwarding Bandwidth 

16 Gbps 

Flash memory 

32 MB 

Memory DRAM 

64MB 

Max VLANs 

64 

VLAN IDs 

4K 

Maximum transmission unit (MTU) 

Up to 9,000 bytes 

Jumbo frames  

9,016 bytes  

Forwarding rate 

2960-8TC-S 

2.7 Mpps 

2960-24-S 

3.6 Mpps 

2960-24TC-S 

6.5 Mpps 

Performance 

2960-24PC-S 

6.5 Mpps 

Содержание 2960-24-S - Catalyst Switch

Страница 1: ...es that are pervasive in the network are critical for secure operations and end to end security is obtained using the Cisco Catalyst 2960 Series Switches with LAN Lite software An array of Cisco security solutions is available including Cisco Clean Access NAC based solutions Overall the functionality available in Cisco Catalyst 2960 Series Switches with LAN Lite software provides peace of mind whe...

Страница 2: ... encapsulating years of Cisco networking expertise As devices connect to the switch automatic port configuration is enabled allowing a plug and play of the device onto the network For example an IP phone connecting to the switch will configure the switch port with Cisco best practices for QoS and create a voice VLAN Cisco SmartPort macros offer a set of verified pretested Cisco recommended switch ...

Страница 3: ...witches In addition to Cisco Network Assistant Cisco Catalyst 2960 LAN Lite Switches provide for extensive management using SNMP network management platforms such as the CiscoWorks LAN Management Solution LMS CiscoWorks LMS is a suite of powerful management tools that simplify the configuration administration monitoring and troubleshooting of Cisco networks It integrates these capabilities into a ...

Страница 4: ... switches that can efficiently deliver high bandwidth applications across the network and optimize network performance saving bandwidth It supports distributed applications and enables next generation multimedia applications including Corporate Communications E learning IP Video Surveillance High Definition Video and distribution of data to desktops in a scalable reliable and efficient manner Cisc...

Страница 5: ... TACACS or RADIUS authentication enables centralized access control of switches and restricts unauthorized users from altering the configurations Alternatively you can configure a local username and password database on the switch itself Fifteen levels of authorization on the switch console and two levels on the web based management interface allow you to give different levels of configuration cap...

Страница 6: ...econvergence on a per VLAN spanning tree basis without requiring the implementation of spanning tree instances IEEE 802 1d Spanning Tree Protocol support for redundant backbone connections and loop free networks simplifies network configuration and improves fault tolerance IEEE 802 1s Multiple Spanning Tree Protocol MSTP allows a spanning tree instance per VLAN enabling Layer 2 load sharing on red...

Страница 7: ...pply The connector is located at the back of the switch These switches do not have a redundant power supply port The internal power supply is an autoranging unit The internal power supply supports input voltages between 100 and 240 VAC Use the supplied AC power cord to connect the AC power connector to an AC power outlet Indicators Per port status Link integrity disabled activity speed and full du...

Страница 8: ...o 4 000 m 10 to 85 noncondensing Operating relative humidity 10 to 85 noncondensing Storage relative humidity Environmental Ranges Not more than following in one year period 96 consecutive hours or 360 hours total or 15 occurrences ISO 7779 ISO 9296 Bystander positions operating to an ambient temperature of 25 C Sound pressure LpA Typical 2960 8TC S No Fan 0 dB 2960 24 S 40 dB 2960 24TC S 40 dB 29...

Страница 9: ...T S 63W 214 BTU hour Switch Power Consumption PoE Power Total Output BTU 2960 24PC S 433W 357W 1471 BTU hour 2960 24LC S 162W 119W 550 BTU hour Measured 100 Throughput Power Consumption with maximum possible PoE loads 2960 48PST S 460W 339W 1563 BTU hour Switch Power Consumption PoE Power Total Output BTU 2960 24PC S 237W 185W 814 BTU hour 2960 24LC S 98W 62W 835 BTU hour Measured 5 Throughput Pow...

Страница 10: ...O STP EXTENSIONS MIB CISCO SYSLOG MIB Cisco UDLDP MIB CISCO TC MIB CISCO TCP MIB CISCO UDLDP MIB CISCO VLAN IFTABLE RELATIONSHIP MIB CISCO VLAN MEMBERSHIP MIB CISCO VTP MIB ENTITY MIB ETHERLIKE MIB IEEE8021 PAE MIB IEEE8023 LAG MIB IF MIB INET ADDRESS MIB OLD CISCO CHASSIS MIB OLD CISCO FLASH MIB OLD CISCO INTERFACES MIB OLD CISCO IP MIB OLD CISCO SYS MIB OLD CISCO TCP MIB OLD CISCO TS MIB RFC1213...

Страница 11: ...pecial terms applicable to your hardware warranty Your formal Warranty Statement including the warranty applicable to Cisco software appears in the Cisco Information Packet that accompanies your Cisco product Duration of Hardware Warranty As long as the original End User continues to own or use the Product provided that fan and power supply warranty is limited to five 5 years In the event of disco...

Страница 12: ...on and deployment Installation text and cutover Training Major moves adds and changes Design review and product staging Access to software updates 24 hours Web access to technical repositories Telephone support through the Cisco Technical Assistance Center TAC Advance Replacement of hardware parts Supplements existing staff Helps ensure that functions meet needs Mitigates risk Helps enable proacti...

Страница 13: ...ver module for MMF and SMF 1300 nm wavelength GLC SX MM 1000BASE SX SFP transceiver module for MMF 850 nm wavelength GLC T 1000BASE T SFP transceiver module for Category 5 copper wire GLC GE 100FX 100BASE FX SFP module for Gigabit Ethernet ports 1310 nm wavelength 2 km over MMF GLC FE 100FX 100BASE FX SFP module for 100 Mb ports 1310 nm wavelength 2 km over MMF CAB SM LCSC 1M 1m fiber single mode ...

Страница 14: ...P BPDU Filtering Multilevel Console Security TACACS Port Security Trunk Port Security Security Port Security for Voice VLANs 802 1p Priority Packet Based Storm Control Egress Shaped Queues Priority Queue Global QoS enable QoS Shaped Round Robin SRR Ingress egress Shared Queues Storm Control Quality of Service Ingress Egress Strict Priority Queuing Weighted Tail Drop WTD Configurable IGMP Leave Tim...