background image

 

3

Installing the High-Density Electrical Interface Assemblies on the Cisco ONS 15310-MA

78-17418-01

  High-Density EIA Installation

Figure 2

High-Density EIA Installation

High-Density EIA Installation

To install the EIA on the rear of the shelf assembly, you must first remove the standard sheet metal 
covers. The EIAs use the same screw holes as the standard sheet metal covers, but they use three holes 
for panhead screws and two holes for jack screws. 

When installed with the standard door and cabling on the backplane, the ONS 15310-MA shelf measures 
approximately 13.7 inches deep when fully populated with backplane cables. 

Install the High-Density EIAs

The following parts are needed to install the high-density EIAs. 

#2 Phillips screwdriver

High-density EIA(s)

6-32 x 5/16-inch pan head screws (3, included with EIA)

Caution

Always use the supplied ESD wristband when working with a powered ONS 15310-MA. Plug the 
wristband cable into either of the ESD jacks, on the far left and right faceplates in the shelf. 

151575

EIA installed

on the B Side

EIA installed

on the A Side

Содержание 15310-EIA-HD-A

Страница 1: ... EIA Description page 1 Install the High Density EIAs page 3 Related Documentation page 5 Obtaining Documentation and Submitting a Service Request page 5 High Density EIA Description High density EIAs are attached to the ONS 15310 MA shelf assembly backplane to provide up to 168 transmit and receive DS 1 connections through six Champ connectors per side A and B or six transmit and receive DS 3 EC ...

Страница 2: ... side high density EIAs installed on the ONS 15310 MA 151584 DS1 OUT J8 DS1 IN J9 DS1 OUT J10 DS1 IN J11 DS1 OUT J12 DS1 IN J13 J20 HD DS3 1 3 2 PWR A J6 ALM INPUT J15 IN J16 OUT J17 IN J14 OUT J18 OUT J19 IN PID VID S N BAR CODE CLEI CODE P N COO 48VDC RTN DS1 OUT J21 DS1 IN J22 DS1 OUT J23 DS1 IN J24 DS1 OUT J25 DS1 IN J26 J33 HD DS3 3 1 2 PWR B J1 LAN J31 OUT J30 IN J29 OUT J32 IN J28 IN J27 OU...

Страница 3: ...s for jack screws When installed with the standard door and cabling on the backplane the ONS 15310 MA shelf measures approximately 13 7 inches deep when fully populated with backplane cables Install the High Density EIAs The following parts are needed to install the high density EIAs 2 Phillips screwdriver High density EIA s 6 32 x 5 16 inch pan head screws 3 included with EIA Caution Always use t...

Страница 4: ...nnectors Caution Do not firmly apply pressure to the EIA this could damage the EIA and backplane connectors Step 4 Seat the EIA as flat as possible by gently exerting enough pressure with your hands to only partially seat the connectors Do not try and fully insert the EIA Step 5 Locate the two jack screws on the EIA which are found on the opposite corners Figure 2 on page 3 For example on the B si...

Страница 5: ...ting a service request and gathering additional information see the monthly What s New in Cisco Product Documentation which also lists all new and revised Cisco technical documentation at http www cisco com en US docs general whatsnew whatsnew html Subscribe to the What s New in Cisco Product Documentation as an RSS feed and set content to be delivered directly to your desktop using a reader appli...

Страница 6: ...nded to be actual addresses and phone numbers Any examples command display output network topology diagrams and other figures included in the document are shown for illustrative purposes only Any use of actual IP addresses or phone numbers in illustrative content is unintentional and coincidental 2011 Cisco Systems Inc All rights reserved Printed in the USA on recycled paper containing 10 postcons...

Отзывы: