VCC-F60FV19GE
Rev.900-666-32-00
©2010 CIS Corporation. All rights reserved.
16
LVAL Output
(Normal Scan)
9 H
Video Output
(Normal Scan)
2079 H
VIDEO Output
(Partial Scan)
LVAL Output
(Partial Scan)
9 H
12 H
Total Line(Address 021&022) + 1H
2058 H
Y Offset
12H + Starting Position
(Address016&017)
Effective Line
(Address 019&020)×3+3H
High Speed
Transmit Term
High Speed
Transmit Term
8. Partial Scan Mode Details
Capturing start position and capturing width can be set by 3H via LAN.
Reading out position register (Address 016 & 017): 0(0H)
~
685(2055H)
3H/step
Effective line register (Address 019 & 020): 0(3H)
~
685(2058H) 3H/step
Total line register (Address 021 & 022): 70 (Effective line register × 2) + 2 (Read Only)
Note: Reading out position and effective line shall meet the following condition.
Reading out position re Effective line register = < 685
Otherwise, the value,
685
–
reading out position register
, will be set to the effective line register.
<Example 1>
Conditions: Reading out position register (Address 016 & 017) = 000
Effective line register
(Address 019&020)
Effective Lines
Total Lines register
+
1 H
Frame rate
0
3 H
709 H
44 fps
・
・
・
・
159
480 H
1027 H
30 fps
・
・
・
・
255
768 H
1219 H
26 fps
・
・
・
・
341
1026 H
1391 H
22 fps
・
・
・
・
399
1200 H
1507 H
21 fps
・
・
・
・
685
2058 H
2079
H
15 fps