VCC-F60FV19GE
Rev.900-666-32-00
©2010 CIS Corporation. All rights reserved.
15
LVAL Output
Video Output
FVAL Output
DVAL Output
12H
TTL IN(a)
(CCD Read
Out Signal)
1
9
22
2079
2058H
2070H
(Trigger Input)
Exposure Time
TTL IN(a)
(Trigger Input)
(Sub Pulse)
(CCD Read Out Signal)
SP Output
(Exposure Signal)
a
b
3
CLK
81
CLK
1216
CLK
a
b
532
CLK
Delay(Fixed)
Delay(Fixed)
1.40
μ
s
CLK60MHz
29.13
μ
s
※
(a):0
~
3
7.4. Pulse Width Trigger Timing
□
Trigger operation is CLK sync, V-Sync Reset.
Delay time, from detecting the trigger edge to the start of exposure, is 1.40
μ
s. Delay time, from
detecting the trigger edge to completion of exposure, is 29.13
μ
s.
□
Trigger input can be accepted even when the camera is outputting video signals. However, a shutter
timing, to start the next video output before completion of transferring video output for the prior signals,
can not be worked. Please refer to the “C” below. To input trigger signals when the camera is
outputting video signals for the prior signals, it shall be synchronized with the down edge of camera LVAL
output.
(A)
(A)
(B)
(B)
(B)
(C)
(B)
(D)
(D)
Trigger Invalid
Pulse Width Trigger Mode
✖
Video Output
TTL IN(a)
(Trigger Input)
DVAL Output
SP Output
(Exposure Signal)
Exposure Time
(Pulse Width)
Exposure Time
(Pulse Width)
Exposure Time
(Pulse Width)
(Video Output (C))
✖
(Exposure Time)