VCC-F60FV19GE
Rev.900-666-32-00
©2010 CIS Corporation. All rights reserved.
14
LVAL Output
Video Output
FVAL Output
DVAL Output
12H
TTL IN(a)
(CCD Read
Out Signal)
1
9
22
2079
2058H
2070H
(Trigger Input)
Exposure Time
TTL IN(a)
(Trigger Input)
(Sub Pulse)
(CCD Read Out Signal)
SP Output
(Exposure Signal)
a
b
3
CLK
81
CLK
a
b
1.40
μ
s
CLK60MHz
nHD × 32.07
μ
s+27.73
μ
s
Delay(Fixed)
※
(a):0
~
3
7.3. Standard Trigger Mode Timing
□
Trigger operation is CLK sync, V-Sync Reset.
Delay time, from detecting the trigger edge to the start of exposure, is 1.40
μ
s at RAW mode.
□
Trigger input can be accepted even when the camera is outputting video signals. However, a shutter
timing, to start the next video output before completion of transferring video output for the prior signals,
can not be worked. To input trigger signals when the camera is outputting video signals for the prior
signals, it shall be synchronized with the down edge of camera LVAL output.
□
Trigger input during the execution of exposure (exposure time) shall be ignored. (Refer to the “G” below.)
(E)
(B)
(B)
(F)
Trigger Invalid
(E)
(F)
(F)
(G)
✖
Standard Trigger Mode
Video Output
TTL IN(a)
(Trigger Input)
DVAL Output
SP Output
(Exposure Signal)
Exposure Time (Register Set Value)
Exposure Time (Register Set Value)
(Exposure Time)
✖