VCC-FC20V49PCL
Rev.900-734-33
©2014 CIS Corporation. All rights reserved.
7
Item
Specification
(21)
Safety/Quality standards
UL:
Conform to UL Standard including materials and others.
CE:
Conform to EN55022: 2006 (Class B) for Emmission
Conform to EN61000-6-2: 2005 for Immunity
RoHS:
Conform to RoHS
FCC:
To be applied for FCC Class A Digital Device
This device complies with Part 15 of FCC Rules. Operation is subject to the
followiong two conditions: (1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that
may cause undesired operation.
(22)
Durability
Vibration
Acceleration : 98m/s
2
(10G)
Frequency
: 20
~
200 Hz
Direction
: X,Y,Z 3 directions
Testing time : 120 min for each direction
Shock
No malfunction shall be occurred with 980m/s
2
(100G) for
±
X,
±
Y, and
±
Z, 6
directions. (without package)
(23)
Operation environment
Temperature
Operation guaranteed: -5
℃~
+45
℃
Performance guaranteed: 0
℃~
+40
℃
Humidity
RH 20
~
80% with no condensation
(24)
Storage environment
Temperature
-25
℃
~
+60
℃
Humidity
RH 20
~
80% with no condensation